Jialu Meng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jialu Meng has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Feng Liu
School of Instrumentation and Optoelectronics Engineering, Beihang University, Beijing, China
3 shared publications - Shaowei Lv
School of Instrumentation and Optoelectronics Engineering, Beihang University, Beijing, China
3 shared publications - Xihui Dou
School of Instrumentation and Optoelectronics Engineering, Beihang University, Beijing, China
3 shared publications - Yuzhuo Pei
School of Instrumentation and Optoelectronics Engineering, Beihang University, Beijing, China
3 shared publications - Haojun Tang
Beihang University
2 shared publications - Zhihong Wu
Department of Cardiology, The Second Xiangya Hospital of Central South University, Changsha, China
2 shared publications
Latest Publications
- 29 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
Optimized Design of Dual-Layer Biplanar Coils for Compact Atomic Sensor Systems
In the field of quantum precision measurement, atomic devices based on the spin-exchange relaxation-free (SERF) effect are of growing interest due to their extremely high sensitivity and potential for miniaturization. As the core component for magnetic field generation and control, the coil system plays a critical role in determining field accuracy and instrument stability. With increasing demands for precision and compact design, magnetic coupling between the field and the shielding structure, as well as modulation field crosstalk among multi-sensor systems, have become major factors limiting SERF instrument performance. To overcome the low attenuation efficiency and poor field uniformity of conventional single layer shielding structures, this paper analyzes the design process of self-shielded coils and evaluates the influence of key parameters on magnetic field characteristics. A dual layer biplanar self-shielded coil model is established, and an inverse design method combining the target field method (TFM) with the tornado optimizer with Coriolis force (TOC) is proposed. The method achieves attenuation of external magnetic fields and high uniformity within the sensing region. Simulation results show that the proposed Bx coil improves field uniformity by 54.46% and reduces the attenuation radius by 57.33% compared to conventional optically pumped magnetometers (OPMs) square coils. The accuracy and effectiveness of the simulation were verified through experiments. The proposed design effectively mitigates magnetic crosstalk in array type and multi-sensor systems, offering strong potential for multichannel SERF magnetometers and other high precision quantum measurement applications.
- 29 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
Optimized Design of Dual-Layer Biplanar Coils for Compact Atomic Sensor Systems
In the field of quantum precision measurement, atomic devices based on the spin-exchange relaxation-free (SERF) effect are of growing interest due to their extremely high sensitivity and potential for miniaturization. As the core component for magnetic field generation and control, the coil system plays a critical role in determining field accuracy and instrument stability. With increasing demands for precision and compact design, magnetic coupling between the field and the shielding structure, as well as modulation field crosstalk among multi-sensor systems, have become major factors limiting SERF instrument performance. To overcome the low attenuation efficiency and poor field uniformity of conventional single layer shielding structures, this paper analyzes the design process of self-shielded coils and evaluates the influence of key parameters on magnetic field characteristics. A dual layer biplanar self-shielded coil model is established, and an inverse design method combining the target field method (TFM) with the tornado optimizer with Coriolis force (TOC) is proposed. The method achieves attenuation of external magnetic fields and high uniformity within the sensing region. Simulation results show that the proposed Bx coil improves field uniformity by 54.46% and reduces the attenuation radius by 57.33% compared to conventional optically pumped magnetometers (OPMs) square coils. The accuracy and effectiveness of the simulation were verified through experiments. The proposed design effectively mitigates magnetic crosstalk in array type and multi-sensor systems, offering strong potential for multichannel SERF magnetometers and other high precision quantum measurement applications.
- Open Access
- 14 April 2026
- Published by Elsevier in SSRN Electronic Journal
Compact and High-Stability Laser Power Stabilization System for Atomic Comagnetometer via Polarization Direction Insensitive Pancharatnam-Berry Phase Grating
Quantum sensing technology holds important significance in the forefront of explorations in magnetic field measurement, physics research, and inertial navigation. In optically pumped atomic sensors, laser power stability is essential for maintaining high sensitivity and long-term measurement stability. A major source of power instability is the fluctuation of the polarization direction, which is converted into power noise by polarization-sensitive optical devices, such as polarization beam splitter (PBS). In this work, a compact and high-stability laser power stabilization system for atomic comagnetometers is proposed based on a polarization-direction-insensitive Pancharatnam-Berry phase grating (PDIG). By means of the mentioned PDIG, polarization and power errors induced by fluctuations in the polarization direction are effectively suppressed, and the overall system stability is significantly improved. Experimental results show that, over a continuous 10 hours operation period, the optical power stability is improved by 43.4% compared with that of the conventional PBS-based power-stabilization system. In addition, polarization conversion and beam splitting are integrated into a single device by the PDIG, so that the conventional PBS and quarter-wave plate are replaced, enabling a more compact optical configuration. Further experimental tests performed on a compact atomic comagnetometer incorporating the proposed PDIG-based stabilization scheme demonstrate that, under otherwise identical experimental conditions, the long-term stability is improved by 29.8% compared with the conventional system. A promising route is therefore provided toward highly stable and miniaturized atomic comagnetometer systems for frontier physics exploration and inertial navigation applications.
- 14 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCompact and High-Stability Laser Power Stabilization System for Atomic Comagnetometer via Polarization Direction Insensitive Pancharatnam-Berry Phase Grating
Quantum sensing technology holds important significance in the forefront of explorations in magnetic field measurement, physics research, and inertial navigation. In optically pumped atomic sensors, laser power stability is essential for maintaining high sensitivity and long-term measurement stability. A major source of power instability is the fluctuation of the polarization direction, which is converted into power noise by polarization-sensitive optical devices, such as polarization beam splitter (PBS). In this work, a compact and high-stability laser power stabilization system for atomic comagnetometers is proposed based on a polarization-direction-insensitive Pancharatnam-Berry phase grating (PDIG). By means of the mentioned PDIG, polarization and power errors induced by fluctuations in the polarization direction are effectively suppressed, and the overall system stability is significantly improved. Experimental results show that, over a continuous 10 hours operation period, the optical power stability is improved by 43.4% compared with that of the conventional PBS-based power-stabilization system. In addition, polarization conversion and beam splitting are integrated into a single device by the PDIG, so that the conventional PBS and quarter-wave plate are replaced, enabling a more compact optical configuration. Further experimental tests performed on a compact atomic comagnetometer incorporating the proposed PDIG-based stabilization scheme demonstrate that, under otherwise identical experimental conditions, the long-term stability is improved by 29.8% compared with the conventional system. A promising route is therefore provided toward highly stable and miniaturized atomic comagnetometer systems for frontier physics exploration and inertial navigation applications.