Chuan-Chun Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chuan-Chun Chang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ben-Yi Liau
Department of Automatic Control Engineering Feng Chia University Taichung Taiwan
2 shared publications - Chi-Wen Lung
Rehabilitation Engineering Lab, Department of Health and Kinesiology University of Illinois at Urbana‐Champaign Urbana Illinois USA
2 shared publications - Qi-Qian Lu
Department of Automatic Control Engineering, Feng Chia University, Taichung, Taiwan
2 shared publications - Yi-Sheng Chen
Department of Communications Engineering, Feng Chia University, Taichung, Taiwan
2 shared publications - Yi-You Wang
Department of Automatic Control Engineering, Feng Chia University, Taichung, Taiwan
2 shared publications - Yih-Kuen Jan
Department of Health and Kinesiology University of Illinois at Urbana‐Champaign Urbana Illinois USA
2 shared publications
Latest Publications
- Open Access
- 21 April 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e88488
Autoencoder-Enhanced Convolutional Neural Networks for Plantar Pressure–Based Gait Pattern Recognition: Model Development and Cross-Validated Evaluation Study
Background: Plantar pressure imaging is a stable modality that reflects gait-related biomechanical characteristics and has been used increasingly for gait assessment and recognition. However, plantar pressure images are high dimensional and nonlinear, making manual feature engineering and conventional machine learning insufficient to capture discriminative patterns. Objective: This study aimed to develop a gait pattern recognition model based on plantar pressure using an autoencoder (AE)-enhanced convolutional neural network (CNN) and to evaluate its performance against baseline deep learning and classical machine learning approaches. Methods: A total of 13 healthy volunteers (aged 18-24 years) were recruited. Plantar pressure data were collected during treadmill walking using an in-shoe pressure measurement system and converted into frame-wise plantar pressure images. We compared a lightweight CNN (Light CNN), an AE-CNN cascade model, and an encoder-augmented CNN with an additional bottleneck layer. Model development used participant-wise data partitioning, and performance was evaluated using accuracy, precision, recall, and F1-score. Results: The proposed encoder-augmented CNN achieved the best overall performance (F1-score=96.20%), outperforming the Light CNN (F1-score=94.44%) and AE-CNN cascade (F1-score=92.45%). Confusion matrices and learning curves further indicated stable training behavior and consistent classification performance across gait patterns. Conclusions: Integrating representation learning (AE-based compression) with CNN-based classification improved the recognition of gait patterns from plantar pressure images. This pilot study included only healthy participants. Future work should validate generalizability in larger and clinically diverse cohorts and further investigate participant-level evaluation and model interpretability, as well as deployment feasibility.
- 21 April 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e88488
Open AccessAutoencoder-Enhanced Convolutional Neural Networks for Plantar Pressure–Based Gait Pattern Recognition: Model Development and Cross-Validated Evaluation Study
Background: Plantar pressure imaging is a stable modality that reflects gait-related biomechanical characteristics and has been used increasingly for gait assessment and recognition. However, plantar pressure images are high dimensional and nonlinear, making manual feature engineering and conventional machine learning insufficient to capture discriminative patterns. Objective: This study aimed to develop a gait pattern recognition model based on plantar pressure using an autoencoder (AE)-enhanced convolutional neural network (CNN) and to evaluate its performance against baseline deep learning and classical machine learning approaches. Methods: A total of 13 healthy volunteers (aged 18-24 years) were recruited. Plantar pressure data were collected during treadmill walking using an in-shoe pressure measurement system and converted into frame-wise plantar pressure images. We compared a lightweight CNN (Light CNN), an AE-CNN cascade model, and an encoder-augmented CNN with an additional bottleneck layer. Model development used participant-wise data partitioning, and performance was evaluated using accuracy, precision, recall, and F1-score. Results: The proposed encoder-augmented CNN achieved the best overall performance (F1-score=96.20%), outperforming the Light CNN (F1-score=94.44%) and AE-CNN cascade (F1-score=92.45%). Confusion matrices and learning curves further indicated stable training behavior and consistent classification performance across gait patterns. Conclusions: Integrating representation learning (AE-based compression) with CNN-based classification improved the recognition of gait patterns from plantar pressure images. This pilot study included only healthy participants. Future work should validate generalizability in larger and clinically diverse cohorts and further investigate participant-level evaluation and model interpretability, as well as deployment feasibility.
- Open Access
- 26 November 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Autoencoder-Enhanced Convolutional Neural Networks for Plantar Pressure–Based Gait Pattern Recognition: Model Development and Cross-Validated Evaluation Study (Preprint)
BACKGROUND Plantar pressure imaging is a stable modality that reflects gait-related biomechanical characteristics and has been used increasingly for gait assessment and recognition. However, plantar pressure images are high dimensional and nonlinear, making manual feature engineering and conventional machine learning insufficient to capture discriminative patterns. OBJECTIVE This study aimed to develop a gait pattern recognition model based on plantar pressure using an autoencoder (AE)-enhanced convolutional neural network (CNN) and to evaluate its performance against baseline deep learning and classical machine learning approaches. METHODS A total of 13 healthy volunteers (aged 18-24 years) were recruited. Plantar pressure data were collected during treadmill walking using an in-shoe pressure measurement system and converted into frame-wise plantar pressure images. We compared a lightweight CNN (Light CNN), an AE-CNN cascade model, and an encoder-augmented CNN with an additional bottleneck layer. Model development used participant-wise data partitioning, and performance was evaluated using accuracy, precision, recall, and F1-score. RESULTS The proposed encoder-augmented CNN achieved the best overall performance (F1-score=96.20%), outperforming the Light CNN (F1-score=94.44%) and AE-CNN cascade (F1-score=92.45%). Confusion matrices and learning curves further indicated stable training behavior and consistent classification performance across gait patterns. CONCLUSIONS Integrating representation learning (AE-based compression) with CNN-based classification improved the recognition of gait patterns from plantar pressure images. This pilot study included only healthy participants. Future work should validate generalizability in larger and clinically diverse cohorts and further investigate participant-level evaluation and model interpretability, as well as deployment feasibility.
- 26 November 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAutoencoder-Enhanced Convolutional Neural Networks for Plantar Pressure–Based Gait Pattern Recognition: Model Development and Cross-Validated Evaluation Study (Preprint)
BACKGROUND Plantar pressure imaging is a stable modality that reflects gait-related biomechanical characteristics and has been used increasingly for gait assessment and recognition. However, plantar pressure images are high dimensional and nonlinear, making manual feature engineering and conventional machine learning insufficient to capture discriminative patterns. OBJECTIVE This study aimed to develop a gait pattern recognition model based on plantar pressure using an autoencoder (AE)-enhanced convolutional neural network (CNN) and to evaluate its performance against baseline deep learning and classical machine learning approaches. METHODS A total of 13 healthy volunteers (aged 18-24 years) were recruited. Plantar pressure data were collected during treadmill walking using an in-shoe pressure measurement system and converted into frame-wise plantar pressure images. We compared a lightweight CNN (Light CNN), an AE-CNN cascade model, and an encoder-augmented CNN with an additional bottleneck layer. Model development used participant-wise data partitioning, and performance was evaluated using accuracy, precision, recall, and F1-score. RESULTS The proposed encoder-augmented CNN achieved the best overall performance (F1-score=96.20%), outperforming the Light CNN (F1-score=94.44%) and AE-CNN cascade (F1-score=92.45%). Confusion matrices and learning curves further indicated stable training behavior and consistent classification performance across gait patterns. CONCLUSIONS Integrating representation learning (AE-based compression) with CNN-based classification improved the recognition of gait patterns from plantar pressure images. This pilot study included only healthy participants. Future work should validate generalizability in larger and clinically diverse cohorts and further investigate participant-level evaluation and model interpretability, as well as deployment feasibility.