Xiujie Wen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiujie Wen has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Linyi Liu
Department of Orthodontics, Hospital of Stomatology, Southwest Medical University, Luzhou, Sichuan, China
3 shared publicationsRui She
Department of Orthodontics, Hospital of Stomatology, Southwest Medical University, Luzhou, Sichuan, China
3 shared publicationsFang Li
Department of Orthodontics, Beijing Ruitai Stomatology Hospital, Beijing, China
2 shared publications- Lei Yang
Department of Orthodontics, Beijing Ruitai Stomatology Hospital, Beijing, China.
2 shared publications Yayue Zheng
Department of Orthodontics, Hospital of Stomatology, Southwest Medical University, Luzhou, Sichuan, China
2 shared publicationsYunyi Jin
Department of Orthodontics, Beijing Ruitai Stomatology Hospital, Beijing, China
2 shared publications
Latest Publications
- Open Access
- 6 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Effect of 3D‑printed customized base designs on the mechanical retention and bonding strength of metal brackets
The objectives of this study were to (1) evaluate the effect of different customized base designs on the shear bond strength (SBS) of metal orthodontic brackets fabricated by selective laser melting (SLM) and (2) assess their clinical feasibility. Seventy-five extracted human premolars were randomly divided into five groups (n = 15). Five types of bracket bases were designed: smooth base, pin-retention base, mesh base, hexagonal honeycomb base, and hollow honeycomb base. All brackets were fabricated using SLM technology with 316 L stainless steel. SBS was measured using a universal testing machine, and adhesive remnant index (ARI) scores were evaluated under magnification. Statistical analysis was performed using one-way analysis of variance (ANOVA) and Kruskal-Wallis tests. Significant differences in SBS were observed among the groups (P < 0.05). The hollow honeycomb group showed the highest bond strength, followed by the hexagonal honeycomb group. No significant differences in ARI scores were found among the groups (P > 0.05). SLM-fabricated customized orthodontic brackets demonstrated clinically acceptable bonding performance levels. The hollow honeycomb base design significantly improved mechanical retention and bond strength.
- 6 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessEffect of 3D‑printed customized base designs on the mechanical retention and bonding strength of metal brackets
The objectives of this study were to (1) evaluate the effect of different customized base designs on the shear bond strength (SBS) of metal orthodontic brackets fabricated by selective laser melting (SLM) and (2) assess their clinical feasibility. Seventy-five extracted human premolars were randomly divided into five groups (n = 15). Five types of bracket bases were designed: smooth base, pin-retention base, mesh base, hexagonal honeycomb base, and hollow honeycomb base. All brackets were fabricated using SLM technology with 316 L stainless steel. SBS was measured using a universal testing machine, and adhesive remnant index (ARI) scores were evaluated under magnification. Statistical analysis was performed using one-way analysis of variance (ANOVA) and Kruskal-Wallis tests. Significant differences in SBS were observed among the groups (P < 0.05). The hollow honeycomb group showed the highest bond strength, followed by the hexagonal honeycomb group. No significant differences in ARI scores were found among the groups (P > 0.05). SLM-fabricated customized orthodontic brackets demonstrated clinically acceptable bonding performance levels. The hollow honeycomb base design significantly improved mechanical retention and bond strength.
- Open Access
- 19 May 2026
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 54 (5)
Combined use of microimplants and a self-made four-curvature torquing auxiliary arch to manage labial root fenestration of the maxillary incisors: A case report
During orthodontic treatment, ensuring the safety of anterior teeth with exposed roots is crucial. Our report describes the case of a 19-years-old female patient who was treated at a local clinic for severe bimaxillary protrusion. The clinic physician extracted the patient’s seven premolars and one mandibular lateral incisor, resulting in failure of the orthodontic treatment. After this failed treatment at the local clinic, the patient presented to our hospital for follow-up treatment (second treatment). When the patient was transferred to our hospital, she still exhibited a skeletal Class II relationship (A point-nasion-B point angle (ANB): 12.5°) profile, and her anterior teeth were severely upright, with an initial U1-NA of −1.5° (normal value: 22.8° ± 5.7°). This value changed after treatment to 14.32° (normal value 22.8° ± 5.7°). Cone beam computed tomography showed that the roots of the anterior teeth had penetrated the labial cortical bone, and it was challenging to ensure the safety of the second treatment. In our patient, the roots of the anterior teeth safely entered the center of the maxilla, with the U1-NA changing from −1.5° to 11° after treatment with our self-made four-curvature torquing auxiliary arch. Moreover, root length did not change, and root absorption did not occur.
- 19 May 2026
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 54 (5)
Open AccessCombined use of microimplants and a self-made four-curvature torquing auxiliary arch to manage labial root fenestration of the maxillary incisors: A case report
During orthodontic treatment, ensuring the safety of anterior teeth with exposed roots is crucial. Our report describes the case of a 19-years-old female patient who was treated at a local clinic for severe bimaxillary protrusion. The clinic physician extracted the patient’s seven premolars and one mandibular lateral incisor, resulting in failure of the orthodontic treatment. After this failed treatment at the local clinic, the patient presented to our hospital for follow-up treatment (second treatment). When the patient was transferred to our hospital, she still exhibited a skeletal Class II relationship (A point-nasion-B point angle (ANB): 12.5°) profile, and her anterior teeth were severely upright, with an initial U1-NA of −1.5° (normal value: 22.8° ± 5.7°). This value changed after treatment to 14.32° (normal value 22.8° ± 5.7°). Cone beam computed tomography showed that the roots of the anterior teeth had penetrated the labial cortical bone, and it was challenging to ensure the safety of the second treatment. In our patient, the roots of the anterior teeth safely entered the center of the maxilla, with the U1-NA changing from −1.5° to 11° after treatment with our self-made four-curvature torquing auxiliary arch. Moreover, root length did not change, and root absorption did not occur.
- Open Access
- 18 April 2026
- Published by Elsevier in International Dental Journal
- Vol. 76 (3) , 109550
Labiolingual Loading Biomechanics on Central Incisor Under Different Periodontal Conditions: A Finite Element Study
- 18 April 2026
- Published by Elsevier in International Dental Journal
- Vol. 76 (3) , 109550
Open AccessLabiolingual Loading Biomechanics on Central Incisor Under Different Periodontal Conditions: A Finite Element Study
- 23 March 2026
- Published by Elsevier in Cellular Signalling
- Vol. 143, 112505
The p75NTR/Mdm2 signaling axis promotes odontogenic differentiation and mineralization in ectomesenchymal stem cells
- 23 March 2026
- Published by Elsevier in Cellular Signalling
- Vol. 143, 112505
The p75NTR/Mdm2 signaling axis promotes odontogenic differentiation and mineralization in ectomesenchymal stem cells