GLGuangchao Li

Guangchao Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guangchao Li has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Jingchun Fan

    College of Life Sciences and Technology, Jinan University, Guangzhou, China

    1 shared publication
  • Xiaoqin Fan

    The Biobank of Shenzhen Second People’s Hospital, The First Affiliated Hospital of Shenzhen University, Shenzhen, China

    1 shared publication
  • Xiaoyun Peng

    College of Life Sciences and Technology, Jinan University, Guangzhou, China

    1 shared publication
  • Yali Mi

    College of Life Sciences and Technology, Jinan University, Guangzhou, China

    1 shared publication
  • Yuhan Lu

    College of Life Sciences and Technology, Jinan University, Guangzhou, China

    1 shared publication
  • Zhao Yin

    Department of Hematology, The Affiliated Guangdong Second Provincial General Hospital of Jinan University, Guangzhou, China

    1 shared publication

Latest Publications

  • Open Access

    AI-driven lateral flow immunoassay for point-of-care detection of cardiac biomarkers in acute myocardial infarction

    by Yuhan Lu, Xiaoyun Peng, Zhao Yin, Xiaoqin Fan, Jingchun Fan, Yali Mi, Guangchao Li

    A functionalized gold nanoparticle-based lateral flow immunoassay (AuNPs-LFIA) platform integrated with a deep learning-based machine vision model for the rapid and quantitative detection of cardiac biomarkers, myoglobin (Myo) and cardiac troponin I (cTnI). AuNPs@Ab probes with high specificity and stability were prepared. AuNPs were synthesized via the citrate reduction method, functionalized with HS-PEG-COOH, and covalently conjugated to antibodies through EDC/NHS-mediated coupling to yield high specificity and stability. Using this platform, the machine vision-assisted AuNPs-LFIA achieved detection limits of 0.224 ng/mL for Myo and 0.071 ng/mL for cTnI. Quantitative readouts were obtained within 8 min, representing a 46.7% improvement in detection efficiency compared to conventional methods. Analysis of spiked serum samples demonstrated a significant correlation with commercial assay kits (R² > 0.99), further validating the platform’s accuracy and clinical applicability. Overall, this AI-enhanced AuNPs-LFIA platform offers sensitive, rapid, and user-friendly quantification. Its robust scalability provides a practical strategy for point-of-care testing (POCT) in cardiovascular diagnostics, particularly in resource-limited settings. AbstractSection Graphical Abstract The alternative text for this image may have been generated using AI.