ZDZeyu Du

Zeyu Du

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zeyu Du has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Gamma-ray response of a GAGG:Ce scintillator coupled to a 2 × 2 SiPM array

    by Zibo Qin, Zaihong Yang, Kaijie Zhou, Xiangyang Jiang, Zhongtao Shen, Qite Li, Jiawei Bian, Zeyu Du, Cheng-En Liu, Cheng Wang, et al.

    A relatively large 35 × 35 × 20 mm 3 GAGG:Ce scintillator coupled to a 2 × 2 silicon photomultiplier (SiPM) array was characterized for gamma-ray detection, including relative-gain calibration, nonlinear energy response, energy resolution, and timing resolution. The SiPM-array response was well described by a saturation-inspired nonlinear calibration function. For the gain-calibrated individual-readout configuration, energy resolutions of 5.31(9)% at 1173.2 keV and 5.05(8)% at 1332.5 keV were obtained, while offline-simulated summed readout yielded comparable values. Coincidence measurements using 60 Co yielded single-detector timing resolutions of σ = 429(9) ps for individual readout and σ = 425(9) ps for hardware-summed readout. Sensitivity to low-energy gamma rays was also demonstrated by detecting the 59.5-keV line from 24 Am. These results provide a useful performance reference for compact gamma-ray detector designs based on relatively large GAGG:Ce crystals and SiPM-array readout.

  • Erratum: Development and application of position-sensitive double parallel-plate avalanche counter

    by C. Yuan, F.S. Shi, X.D. Xu, Z.C. Zhang, E.Q. Liu, H.R. Yang, P. Ma, L.M. Duan, H.J. Ong, S. Terashima, et al.

  • Development and application of position-sensitive double parallel-plate avalanche counter

    by C. Yuan, F.S. Shi, X.D. Xu, Z.C. Zhang, E.Q. Liu, H.R. Yang, P. Ma, L.M. Duan, H.J. Ong, S. Terashima, et al.

    Double parallel-plate avalanche counters (DPPACs), each comprising two PPACs with delay-line readout for two-dimensional position determination, have been developed at Institute of Modern Physics, Chinese Academy of Sciences. The detector was tested with a standard α source, achieving a position resolution of about 0.4 mm. Each PPAC measures particle hit positions in two dimensions, with the dual configuration enhancing overall detection efficiency. Two DPPACs were deployed in a month-long experimental campaign at the Radioactive Ion Beam Line in Lanzhou (RIBLL1) with secondary beams of 10 Be and 10,11,16 C, and faint 18 O primary beam at typical intensities of 1.2–1.5 × 10 5 Hz, yielding a stable single DPPAC-detection efficiency > 90% and a typical in-beam position resolution ≈ 0.56 mm. This successful deployment addresses a critical domestic need for reliable, high-resolution beam monitoring and establishes a robust technological foundation for future experiments.

  • Run-dependent timing offsets and their correction in digital data acquisition systems

    by Zeyu Du, Zaihong Yang, Haoyu Ge, Wenwu Wan, Hao Jian, Jiawei Bian, Weiliang Pu, Hooi-Jin Ong, Fushuai Shi, Chen Yuan

    Precise time synchronization among multiple electronic channels is essential for nuclear physics experiments. In digital data acquisition systems based on XIA Pixie-16 modules, the relative timing between channels is not necessarily preserved when a new data acquisition run is started. A run-dependent timing offset — typically on the order of 10 ns — can occur independently in each channel, which cannot be corrected through offline data analysis alone. To address this issue, a dedicated external electronic circuit is developed. This circuit operates as a programmable double-throw switch that routs a common reference clock signal to all channels at the start of each run, before switching to normal physics data acquisition. This procedure enables direct measurement and thus correction of relative timing offsets for all channels on a run-by-run basis without manual intervention. The method has been successfully applied in a nuclear reaction experiment using multiple Pixie-16 modules, where it effectively corrects the run-dependent timing offset and thus significantly improves the accuracy of timing-dependent observables such as Parallel Plate Avalanche Counter(PPAC) position reconstruction and beam tracking.