Prajakta Raghudas Volvaikar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Prajakta Raghudas Volvaikar has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Aradhana Nagarsekar
Department of Prosthodontics Goa Dental College and Hospital Bambolim India
3 shared publications - Ridhima Gaunkar
Department of Public Health Dentistry Goa Dental College and Hospital Bambolim Goa India
3 shared publications - Meena Ajay Aras
Department of Prosthodontics Goa Dental College and Hospital Bambolim India
2 shared publications - Umesh Yeshwanth Pai
Department of Prosthodontics and Crown & Bridge, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104
2 shared publications - Anushka Kunkolienkar
Department of Prosthodontics, Goa Dental College and Hospital, Bambolim-Goa, India
1 shared publication - Kennedy Mascarenhas
Department of Prosthodontics, Goa Dental College and Hospital, Bambolim-Goa, India
1 shared publication
Latest Publications
- Open Access
- 14 July 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 38 (11) , 2199-2206
Effect of Glazing Dwell Time and Cooling Duration on Flexural Strength and Surface Microhardness of 3 mol% Yttria‐Stabilized Tetragonal Zirconia: An In Vitro Study
Objective: To evaluate the effect of glazing dwell time and cooling duration on the flexural strength and surface microhardness of high‐translucency 3 mol% yttria‐stabilized tetragonal zirconia polycrystal (3Y‐TZP). Materials and Methods: Total of 108 rectangular zirconia specimens (20 × 4 × 2 mm) were fabricated from preshaded monolithic blocks and sintered at 1530°C. Specimens were divided into nine groups ( n = 12). The control group (NG) remained unglazed. Experimental groups underwent conventional firing (CF;1‐min dwell) or extended firing (EF; 3‐min dwell) at 850°C, each combined with four cooling durations (4,7,9, or 12 min) between 850°C and 600°C. Flexural strength was evaluated using a four‐point bending test (ISO 6872:2015) with Weibull analysis, while surface microhardness was measured using the Vickers method (50 g, 10 s). Data were analyzed using two‐way ANOVA and Tukey's HSD test ( α = 0.05). Results: Significant differences were observed in flexural strength and microhardness ( p < 0.001). The unglazed group showed the highest strength (698 ± 18 MPa; m = 46). Among glazed groups, EF3 (3‐min dwell/9‐min cooling) exhibited the highest characteristic strength ( σ ₀ = 657 MPa). EF1 (3‐min dwell/4‐min cooling) showed the lowest strength (466 ± 23 MPa), below ISO requirements. Microhardness decreased with longer cooling durations. Conclusions: Glazing parameters significantly affect 3Y‐TZP properties. Extended firing with controlled slow cooling (9 min) optimizes strength and reliability, while rapid cooling compromises performance.
- 14 July 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 38 (11) , 2199-2206
Open AccessEffect of Glazing Dwell Time and Cooling Duration on Flexural Strength and Surface Microhardness of 3 mol% Yttria‐Stabilized Tetragonal Zirconia: An In Vitro Study
Objective: To evaluate the effect of glazing dwell time and cooling duration on the flexural strength and surface microhardness of high‐translucency 3 mol% yttria‐stabilized tetragonal zirconia polycrystal (3Y‐TZP). Materials and Methods: Total of 108 rectangular zirconia specimens (20 × 4 × 2 mm) were fabricated from preshaded monolithic blocks and sintered at 1530°C. Specimens were divided into nine groups ( n = 12). The control group (NG) remained unglazed. Experimental groups underwent conventional firing (CF;1‐min dwell) or extended firing (EF; 3‐min dwell) at 850°C, each combined with four cooling durations (4,7,9, or 12 min) between 850°C and 600°C. Flexural strength was evaluated using a four‐point bending test (ISO 6872:2015) with Weibull analysis, while surface microhardness was measured using the Vickers method (50 g, 10 s). Data were analyzed using two‐way ANOVA and Tukey's HSD test ( α = 0.05). Results: Significant differences were observed in flexural strength and microhardness ( p < 0.001). The unglazed group showed the highest strength (698 ± 18 MPa; m = 46). Among glazed groups, EF3 (3‐min dwell/9‐min cooling) exhibited the highest characteristic strength ( σ ₀ = 657 MPa). EF1 (3‐min dwell/4‐min cooling) showed the lowest strength (466 ± 23 MPa), below ISO requirements. Microhardness decreased with longer cooling durations. Conclusions: Glazing parameters significantly affect 3Y‐TZP properties. Extended firing with controlled slow cooling (9 min) optimizes strength and reliability, while rapid cooling compromises performance.
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Dentistry
- Vol. 2026 (1) , 3425087
Prosthodontic Rehabilitation as Essential Care Within India’s District Health System: A Narrative Review and Conceptual Framework
Background: Despite the National Oral Health Programme (NOHP) mandating the provision of removable partial and complete dentures (CDs) at the district level, prosthodontic services in public facilities remain largely inaccessible across most Indian states, even after more than a decade of policy implementation. With India’s elderly population projected to reach 347 million by 2050 and complete edentulism affecting 12%–14% of older adults, the unmet need for prosthodontic care is substantial and continues to grow. Aim: This narrative review synthesises available evidence on the burden and impact of edentulism, along with policy responses in India and comparable settings. It further proposes a conceptual framework for essential prosthodontic care within India’s district health system (DHS), positioning prosthodontic rehabilitation as a core health service, comparable to cataract surgery and hearing rehabilitation. Methods: A narrative review was conducted following scale for the assessment of narrative review articles (SANRA) guidelines, drawing on epidemiological data, policy documents, low‐ and middle‐income country (LMIC) programme evaluations and health economics evidence. Synthesis and Proposed Framework: Nine critical implementation gaps were identified from the literature. In response, the DHS Essential Prosthodontic Services Framework is proposed, comprising a five‐tier service package with the district hospitals as nodal fabrication units; a hub‐and‐spoke laboratory model; eligibility and benefit structure aligned with PM‐JAY; integration with National Programme for Health Care of the Elderly (NPHCE) and Ayushman Bharat; eight key performance indicators and a phased 10‐year implementation roadmap. Conclusion: Framing prosthodontic rehabilitation as essential care comparable to cataract surgery provides the most practical and sustainable basis for the administrative reforms required to translate existing policy intent into functional district‐level service delivery.
- 1 January 2026
- Published by Wiley in International Journal of Dentistry
- Vol. 2026 (1) , 3425087
Open AccessProsthodontic Rehabilitation as Essential Care Within India’s District Health System: A Narrative Review and Conceptual Framework
Background: Despite the National Oral Health Programme (NOHP) mandating the provision of removable partial and complete dentures (CDs) at the district level, prosthodontic services in public facilities remain largely inaccessible across most Indian states, even after more than a decade of policy implementation. With India’s elderly population projected to reach 347 million by 2050 and complete edentulism affecting 12%–14% of older adults, the unmet need for prosthodontic care is substantial and continues to grow. Aim: This narrative review synthesises available evidence on the burden and impact of edentulism, along with policy responses in India and comparable settings. It further proposes a conceptual framework for essential prosthodontic care within India’s district health system (DHS), positioning prosthodontic rehabilitation as a core health service, comparable to cataract surgery and hearing rehabilitation. Methods: A narrative review was conducted following scale for the assessment of narrative review articles (SANRA) guidelines, drawing on epidemiological data, policy documents, low‐ and middle‐income country (LMIC) programme evaluations and health economics evidence. Synthesis and Proposed Framework: Nine critical implementation gaps were identified from the literature. In response, the DHS Essential Prosthodontic Services Framework is proposed, comprising a five‐tier service package with the district hospitals as nodal fabrication units; a hub‐and‐spoke laboratory model; eligibility and benefit structure aligned with PM‐JAY; integration with National Programme for Health Care of the Elderly (NPHCE) and Ayushman Bharat; eight key performance indicators and a phased 10‐year implementation roadmap. Conclusion: Framing prosthodontic rehabilitation as essential care comparable to cataract surgery provides the most practical and sustainable basis for the administrative reforms required to translate existing policy intent into functional district‐level service delivery.
- Open Access
- 1 January 2026
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 18 (2) , 92-102
Comparison of subgingival finish line reproduction in intraoral scanning versus conventional impressions: a randomized crossover clinical study with/without gingival retraction
To evaluate the competence of intraoral scanners in recording subgingival finish lines compared with conventional impressions, with and without gingival retraction. A randomized crossover, clinical trial was conducted on 15 participants. Mandibular first molars were prepared for full-coverage crowns, and four impression techniques were performed: digital without retraction (DWR), digital with retraction (DR), conventional without retraction (CWR), and conventional with retraction (CR). A 1-week washout separated digital and conventional methods. STL files were generated and superimposed using a best-fit algorithm. Measurements were made at three sites (B-buccal, M-mesial, D-distal) for finish line width(1), depth(2), and gingival retraction(3). Significant intergroup differences were noted in B3, M1, M3, and D3. In these subgroups, DWR consistently demonstrated lower reproducibility. In B3, DR and CR were significantly better than DWR. In M1 and D3, DR, CWR, and CR showed significantly superior reproduction compared to DWR. In M3, CR showed significantly better results than DWR. Other parameters were comparable across groups. Digital and conventional impressions demonstrated higher reproducibility for shallow subgingival finish lines when gingival retraction was done. Without gingival retraction, finish line reproduced by conventional impressions was more defined than digital, underscoring the importance of retraction for reliable digital capture of subgingival margins.
- 1 January 2026
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 18 (2) , 92-102
Open AccessComparison of subgingival finish line reproduction in intraoral scanning versus conventional impressions: a randomized crossover clinical study with/without gingival retraction
To evaluate the competence of intraoral scanners in recording subgingival finish lines compared with conventional impressions, with and without gingival retraction. A randomized crossover, clinical trial was conducted on 15 participants. Mandibular first molars were prepared for full-coverage crowns, and four impression techniques were performed: digital without retraction (DWR), digital with retraction (DR), conventional without retraction (CWR), and conventional with retraction (CR). A 1-week washout separated digital and conventional methods. STL files were generated and superimposed using a best-fit algorithm. Measurements were made at three sites (B-buccal, M-mesial, D-distal) for finish line width(1), depth(2), and gingival retraction(3). Significant intergroup differences were noted in B3, M1, M3, and D3. In these subgroups, DWR consistently demonstrated lower reproducibility. In B3, DR and CR were significantly better than DWR. In M1 and D3, DR, CWR, and CR showed significantly superior reproduction compared to DWR. In M3, CR showed significantly better results than DWR. Other parameters were comparable across groups. Digital and conventional impressions demonstrated higher reproducibility for shallow subgingival finish lines when gingival retraction was done. Without gingival retraction, finish line reproduced by conventional impressions was more defined than digital, underscoring the importance of retraction for reliable digital capture of subgingival margins.