Hugues Vinzant
Research Subjects
Research Interests
Hugues Vinzant has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Alexandre Dalibot
A-go SAS
2 shared publications- Baptiste Perthuy
Normandie Univ, UNICAEN, INSERM, COMETE, CYCERON, CHU Caen, 14000 Caen, France
2 shared publications Clement Brifault
A-go SAS
2 shared publications- Leslie Marion Decker
Normandie Univ, UNICAEN, INSERM, COMETE, CYCERON, CHU Caen, 14000 Caen, France
2 shared publications - Fabien Cignetti
Univ. Grenoble Alpes, Inserm, U1216, Grenoble Institut Neurosciences, 38000 Grenoble, France
1 shared publication - Nicholas Stergiou
Aristotle University of Thessaloniki
1 shared publication
Latest Publications
- Open Access
From linear to nonlinear gait measures: validity of a multi-view markerless motion capture system
Markerless motion capture offers a practical alternative to marker-based optoelectronic systems, yet validation studies have focused almost exclusively on linear gait measures. Nonlinear measures of gait dynamics, sensitive to the fine temporal structure of locomotor signals, remain unvalidated in markerless systems. This study assessed the concurrent validity of a three-camera markerless system against a 15-camera optoelectronic system across four treadmill speeds in 22 healthy adults. Inter-system agreement was evaluated for spatiotemporal parameters (mean, variability, detrended fluctuation analysis [DFA] scaling exponents) and for joint angle and trunk acceleration time series (maximum Lyapunov exponents, sample entropy, Attractor Complexity Index [ACI]). Temporal measures reached near-perfect agreement, and spatial measures showed good to excellent agreement with small speed-dependent positive biases. Sagittal-plane joint kinematic waveforms were compared using statistical parametric mapping, with root-mean-square error (RMSE) reported for significant intervals. Agreement was best at the hip, with knee and ankle showing comparable, higher error (RMSE: 1.2–3.0° hip, 3.7–5.5° knee and 3.8–5.1° ankle). ACI demonstrated moderate to good agreement across all joints and good agreement across trunk acceleration directions. Most DFA scaling exponents for step-based series supported group-level comparisons: both measures are usable for markerless assessment of gait's nonlinear dynamics. Maximum Lyapunov exponents and sample entropy showed lower absolute agreement: at the hip and knee, they preserved inter-individual ranking and remained usable for within-system group comparisons, but agreement collapsed at the ankle and for trunk sample entropy, indicating these measures still need refinement. These findings define a tiered, measure-specific scope for markerless gait analysis, extending validation beyond spatiotemporal parameters.
Open AccessFrom linear to nonlinear gait measures: validity of a multi-view markerless motion capture system
Markerless motion capture offers a practical alternative to marker-based optoelectronic systems, yet validation studies have focused almost exclusively on linear gait measures. Nonlinear measures of gait dynamics, sensitive to the fine temporal structure of locomotor signals, remain unvalidated in markerless systems. This study assessed the concurrent validity of a three-camera markerless system against a 15-camera optoelectronic system across four treadmill speeds in 22 healthy adults. Inter-system agreement was evaluated for spatiotemporal parameters (mean, variability, detrended fluctuation analysis [DFA] scaling exponents) and for joint angle and trunk acceleration time series (maximum Lyapunov exponents, sample entropy, Attractor Complexity Index [ACI]). Temporal measures reached near-perfect agreement, and spatial measures showed good to excellent agreement with small speed-dependent positive biases. Sagittal-plane joint kinematic waveforms were compared using statistical parametric mapping, with root-mean-square error (RMSE) reported for significant intervals. Agreement was best at the hip, with knee and ankle showing comparable, higher error (RMSE: 1.2–3.0° hip, 3.7–5.5° knee and 3.8–5.1° ankle). ACI demonstrated moderate to good agreement across all joints and good agreement across trunk acceleration directions. Most DFA scaling exponents for step-based series supported group-level comparisons: both measures are usable for markerless assessment of gait's nonlinear dynamics. Maximum Lyapunov exponents and sample entropy showed lower absolute agreement: at the hip and knee, they preserved inter-individual ranking and remained usable for within-system group comparisons, but agreement collapsed at the ankle and for trunk sample entropy, indicating these measures still need refinement. These findings define a tiered, measure-specific scope for markerless gait analysis, extending validation beyond spatiotemporal parameters.
- Open Access
Beyond gait speed: a multidimensional motor signature of Motoric Cognitive Risk syndrome identified through domain-specific anomaly detection
Motoric Cognitive Risk (MCR) syndrome, defined by subjective cognitive complaints and slow gait speed, identifies older adults at increased risk of major neurocognitive disorders (NCDs). Yet, gait speed reflects a composite output shaped by heterogeneous neuromusculoskeletal and cognitive processes, limiting its clinical specificity. This study aimed to refine the motor signature of MCR by quantifying domain-specific gait deviations relative to a normative reference cohort using an anomaly detection approach. Ninety-seven adults (≥ 55 years) completed two 3-minute treadmill walking bouts at their preferred speed. Participants were categorized into three groups: older adults with MCR (n = 20), healthy older adults with slow gait (sHOA; n = 20) matched to MCR for age and gait speed, and healthy older adults (HOA; n = 57). Linear spatiotemporal and nonlinear trunk acceleration-derived variables were organized into ten functional gait domains, conceptually grouped into gait pattern (pace, rhythm, phases, postural control, symmetry), fluctuation amplitude (variability), and temporal structure of fluctuations (regulation, signal complexity, divergence of movement trajectories, and attractor complexity). For each domain, a Gaussian mixture model trained on HOA data defined a normative reference space, from which individual anomaly scores quantified deviations across groups. Both sHOA and MCR showed higher deviations in gait pattern domains (pace and phases) than HOA, consistent with their slower gait speed. Only MCR exhibited additional deviations in domains related to fluctuation amplitude and temporal structure, reflected by increased step-to-step variability and trunk acceleration fluctuations that were more divergent, more predictable, and less complex. These findings reveal a multidimensional motor signature of MCR. Domain-specific anomaly scores may provide individualized, clinically interpretable biomarkers to support early detection and monitoring of older adults at increased risk of major NCDs.
Open AccessBeyond gait speed: a multidimensional motor signature of Motoric Cognitive Risk syndrome identified through domain-specific anomaly detection
Motoric Cognitive Risk (MCR) syndrome, defined by subjective cognitive complaints and slow gait speed, identifies older adults at increased risk of major neurocognitive disorders (NCDs). Yet, gait speed reflects a composite output shaped by heterogeneous neuromusculoskeletal and cognitive processes, limiting its clinical specificity. This study aimed to refine the motor signature of MCR by quantifying domain-specific gait deviations relative to a normative reference cohort using an anomaly detection approach. Ninety-seven adults (≥ 55 years) completed two 3-minute treadmill walking bouts at their preferred speed. Participants were categorized into three groups: older adults with MCR (n = 20), healthy older adults with slow gait (sHOA; n = 20) matched to MCR for age and gait speed, and healthy older adults (HOA; n = 57). Linear spatiotemporal and nonlinear trunk acceleration-derived variables were organized into ten functional gait domains, conceptually grouped into gait pattern (pace, rhythm, phases, postural control, symmetry), fluctuation amplitude (variability), and temporal structure of fluctuations (regulation, signal complexity, divergence of movement trajectories, and attractor complexity). For each domain, a Gaussian mixture model trained on HOA data defined a normative reference space, from which individual anomaly scores quantified deviations across groups. Both sHOA and MCR showed higher deviations in gait pattern domains (pace and phases) than HOA, consistent with their slower gait speed. Only MCR exhibited additional deviations in domains related to fluctuation amplitude and temporal structure, reflected by increased step-to-step variability and trunk acceleration fluctuations that were more divergent, more predictable, and less complex. These findings reveal a multidimensional motor signature of MCR. Domain-specific anomaly scores may provide individualized, clinically interpretable biomarkers to support early detection and monitoring of older adults at increased risk of major NCDs.