Jiaqi Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiaqi Li has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Liming Qian
Department of Mechanical Engineering, Nantong Institute of Technology, Nantong 226002, China
2 shared publications - Feng Guo
Department of Mechanical Engineering, Nantong Institute of Technology, Nantong 226002, China
1 shared publication - Guifang Xu
School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013, China
1 shared publication - Hai Gu
School of Mechanical Engineering, Nantong Institute of Technology, Nantong 226002, China
1 shared publication - Rongrong Ge
School of Mechanical Engineering (School of Intelligent Manufacturing), Nantong Institute of Technology, Nantong 226002, China
1 shared publication - Rui Wang
School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
1 shared publication
Latest Publications
- Open Access
- 29 October 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (11) , 1254
A Soft Magnetic Tactile Sensor with Simulation-Guided History Compensation for Sub-Millimeter Contact Trajectory Tracking
Soft magnetic tactile trajectory reconstruction depends on motion and deformation history. We investigated whether an empirical dynamic simulator could inform useful refinements of an existing real-trained reconstruction chain. Virtual exploration and real-record observations motivated a function-preserving multiscale causal-history expansion trained with real data only. In two source sessions, the selected joint-objective model reduced mean command-referenced planar error from 0.436 to 0.408 mm and from 0.452 to 0.424 mm, with approximately 45% lower residual step root-mean-square (RMS). Eighteen matched runs from one initialization showed that additional data and optimization alone did not reproduce the large stability gain; a representative residual gated-recurrent-unit (GRU) model did not reproduce it either. Eight sequences from a partial repeat execution of the test plan supported joint error and stability improvement. Measurements acquired after the original model freeze supplied a separate hemispherical-indenter check: in six of 12 sequences that met a fixed baseline-comparability criterion, the common-output planar error decreased from 0.474 to 0.453 mm and the residual step RMS from 0.259 to 0.169 mm. Eight-direction holds showed lower within-hold fluctuation but not consistently lower between-direction mean bias; the median paired command-response-proxy difference was zero. Command-derived references, limited assemblies and unmeasured physical uncertainty bound stronger accuracy and latency interpretations.
- 29 October 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (11) , 1254
Open AccessA Soft Magnetic Tactile Sensor with Simulation-Guided History Compensation for Sub-Millimeter Contact Trajectory Tracking
Soft magnetic tactile trajectory reconstruction depends on motion and deformation history. We investigated whether an empirical dynamic simulator could inform useful refinements of an existing real-trained reconstruction chain. Virtual exploration and real-record observations motivated a function-preserving multiscale causal-history expansion trained with real data only. In two source sessions, the selected joint-objective model reduced mean command-referenced planar error from 0.436 to 0.408 mm and from 0.452 to 0.424 mm, with approximately 45% lower residual step root-mean-square (RMS). Eighteen matched runs from one initialization showed that additional data and optimization alone did not reproduce the large stability gain; a representative residual gated-recurrent-unit (GRU) model did not reproduce it either. Eight sequences from a partial repeat execution of the test plan supported joint error and stability improvement. Measurements acquired after the original model freeze supplied a separate hemispherical-indenter check: in six of 12 sequences that met a fixed baseline-comparability criterion, the common-output planar error decreased from 0.474 to 0.453 mm and the residual step RMS from 0.259 to 0.169 mm. Eight-direction holds showed lower within-hold fluctuation but not consistently lower between-direction mean bias; the median paired command-response-proxy difference was zero. Command-derived references, limited assemblies and unmeasured physical uncertainty bound stronger accuracy and latency interpretations.
- Open Access
Study on the Microstructure and Properties of Plasma-Sprayed HA/ZrO2/Nb Composite Coatings with Varying Nb Contents
Magnesium alloys are promising biodegradable implants, but rapid degradation and insufficient early-stage bioactivity limit their clinical use. In this study, hydroxyapatite (HA)/zirconia (ZrO2)/niobium (Nb) composite coatings with varying Nb contents (10, 20, and 30%) were deposited on ZK60 magnesium alloys via atmospheric plasma spraying. The coatings retained feedstock phases while forming tetracalcium phosphate, tricalcium phosphate, and Nb2O5 during spraying. Microstructurally, increasing Nb to 30% induced an interconnected porous network, resulting in increased surface microhardness (~426 HV) and hydrophilicity (contact angle ~50°). Electrochemical tests revealed that, among the investigated compositions, the 20% Nb coating exhibited the lowest corrosion current density (Icorr = 9.688 × 10−5 A/cm2), indicating the most favorable electrochemical behavior within the tested Nb-content range. Although further increasing Nb to 30% resulted in a higher Icorr than that of the 20% Nb coating, H1Z3N exhibited the highest day-5 OD450 value and favorable cell spreading. This cellular response may be associated with its higher surface roughness, enhanced wettability, and porous architecture. Overall, the investigated compositions exhibited an observed trade-off between electrochemical behavior and cytocompatibility.
Open AccessStudy on the Microstructure and Properties of Plasma-Sprayed HA/ZrO2/Nb Composite Coatings with Varying Nb Contents
Magnesium alloys are promising biodegradable implants, but rapid degradation and insufficient early-stage bioactivity limit their clinical use. In this study, hydroxyapatite (HA)/zirconia (ZrO2)/niobium (Nb) composite coatings with varying Nb contents (10, 20, and 30%) were deposited on ZK60 magnesium alloys via atmospheric plasma spraying. The coatings retained feedstock phases while forming tetracalcium phosphate, tricalcium phosphate, and Nb2O5 during spraying. Microstructurally, increasing Nb to 30% induced an interconnected porous network, resulting in increased surface microhardness (~426 HV) and hydrophilicity (contact angle ~50°). Electrochemical tests revealed that, among the investigated compositions, the 20% Nb coating exhibited the lowest corrosion current density (Icorr = 9.688 × 10−5 A/cm2), indicating the most favorable electrochemical behavior within the tested Nb-content range. Although further increasing Nb to 30% resulted in a higher Icorr than that of the 20% Nb coating, H1Z3N exhibited the highest day-5 OD450 value and favorable cell spreading. This cellular response may be associated with its higher surface roughness, enhanced wettability, and porous architecture. Overall, the investigated compositions exhibited an observed trade-off between electrochemical behavior and cytocompatibility.
- Open Access
Study on the Microstructure and Properties of Nb/ZrO2/HA Composite Coatings by Plasma Spraying Process Parameters
In this study, niobium/zirconium dioxide/hydroxyapatite (Nb/ZrO2/HA) composite coating was deposited on ZK60 magnesium alloy by the plasma spraying technique. The effects of spraying power and the powder feeding rate on the surface morphology, corrosion resistance, surface hardness, and surface roughness were investigated in this study. Tests were conducted through the optimal parameter combination obtained during the optimization process. The Nb/ZrO2/HA coating consisted of α/β-TCP, TTCP, Nb2O5, HA, Nb, and t-ZrO2 phases. The results suggest that the Ca/P ratio of the coating approached the ideal calcium-to-phosphorus ratio characteristic of bone implant material surfaces. Under the parameters of 33 kw and 18 g/min, the coating exhibited a dense, flattened morphology with significantly reduced roughness of Ra = 2.128 μm. Compared to the pure HA coating, the surface hardness and corrosion resistance of the Nb/ZrO2/HA-coated sample increased by 28% and 56%, respectively. Furthermore, the mass loss rate in simulated body fluid (SBF) was considerably decreased by 33% compared to the HA coating. In vitro cytotoxicity assay reveals that the cell proliferation activity of the Nb/ZrO2/HA composite coating was higher than that of the HA/ZrO2 composite coating and the HA coating. Hence, the composite coating possessed favorable degradation controllability and biocompatibility.
Open AccessStudy on the Microstructure and Properties of Nb/ZrO2/HA Composite Coatings by Plasma Spraying Process Parameters
In this study, niobium/zirconium dioxide/hydroxyapatite (Nb/ZrO2/HA) composite coating was deposited on ZK60 magnesium alloy by the plasma spraying technique. The effects of spraying power and the powder feeding rate on the surface morphology, corrosion resistance, surface hardness, and surface roughness were investigated in this study. Tests were conducted through the optimal parameter combination obtained during the optimization process. The Nb/ZrO2/HA coating consisted of α/β-TCP, TTCP, Nb2O5, HA, Nb, and t-ZrO2 phases. The results suggest that the Ca/P ratio of the coating approached the ideal calcium-to-phosphorus ratio characteristic of bone implant material surfaces. Under the parameters of 33 kw and 18 g/min, the coating exhibited a dense, flattened morphology with significantly reduced roughness of Ra = 2.128 μm. Compared to the pure HA coating, the surface hardness and corrosion resistance of the Nb/ZrO2/HA-coated sample increased by 28% and 56%, respectively. Furthermore, the mass loss rate in simulated body fluid (SBF) was considerably decreased by 33% compared to the HA coating. In vitro cytotoxicity assay reveals that the cell proliferation activity of the Nb/ZrO2/HA composite coating was higher than that of the HA/ZrO2 composite coating and the HA coating. Hence, the composite coating possessed favorable degradation controllability and biocompatibility.