Silvia Victoria Prodescu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Silvia Victoria Prodescu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Călin Petru Tătaru
Department of Opthamology, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania
2 shared publications - Cătălina Ioana Tătaru
Clinical Department of Ophthalmology, Carol Davila University of Medicine and Pharmacy, 020021 Bucharest, Romania
2 shared publications - Paul Filip Curcă
Department of Ophthalmology, Central Military Emergency University Hospital “Dr. Carol Davila”, Carol Davila University of Medicine and Pharmacy, 010825 Bucharest, Romania
2 shared publications - Andreea Alexandra Mihaela Musat
Doctoral School, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania
1 shared publication - Mihai Adrian Păsărică
Department of Ophthalmology, Clinical Institute for Ophthalmological Emergencies “Prof. Dr. Mircea Olteanu”, 010464 Bucharest, Romania
1 shared publication - Mihail Zemba
Faculty of Medicine, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania
1 shared publication
Latest Publications
- Open Access
- 17 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (20) , 3380
Artificial Intelligence Applications in Laser-Assisted Refractive Surgery—A Comprehensive Review
Background/Objectives: Artificial Intelligence (AI) technology—in the form of Machine Learning (ML) models and other models specialized in image recognition and processing, such as Convolutional Neural Networks Visual Transformers (CNN-ViTs)—is increasingly being used in ophthalmology. This review summarizes the main AI applications for laser-assisted refractive surgery. Methods: A wide-ranging literature search on the PubMed and ISI Thompson Web of Science databases was conducted. Results: AI is an all-encompassing technological concept that refers to either specific applications of ML/CNN models, such as in keratoconus screening or diagnosis, or agentic/multimodal AI applications that process different data types using a variety of AI models. The most clinically established applications found were corneal ectasia and keratoconus screening, in which AI models can reliably exceed 95% diagnostic accuracy, specificity, and sensitivity; nomogram-derived laser ablation programming; optimization of ray-tracing calculations for ray-traced ablation profiles; patient screening and selection for refractive surgery; visual and refractive result prediction; assessment of postoperative corneal ectasia risk; detection of intraoperative complications; research on the laser coupling effect; and other applications such as monitoring eye rubbing behavior in corneal ectasia suspects. Thus, singular, specific applications of AI models have made the largest clinical contributions. These results must be interpreted with a comparison of internal versus external validation, calibration, and generalizability. Overall the technology is highly promising. Agentic/multimodal AI frameworks are currently being discussed, with pilot studies published and applicability proposed in the context of large, high-patient-volume clinical practices. The technological advent of SHAP force plot graphs and saliency maps has improved understanding of the factors that contribute mechanistically to AI model reasoning, leading to more informed clinical decisions or research applicability, such as in finding parameters or factors linked to postoperative ectasia. Conclusions: AI is already established in laser-assisted refractive surgery in the form of models specialized in data-intensive analysis. At present, the best-performing novel AI models originate from the domain of large or multi-hospital settings due to requirements for multiple latest-generation diagnostic devices, high-volume patient data, computing expertise, and resources. Future directions could include clinical standardization and trickle-down dissemination of the technology. Agentic/multimodal AI has the potential to benefit large clinical/patient settings or offer access to expert knowledge in smaller practice settings. Agentic/multimodal AI implementation is offset by challenges in complexity, the technological limitations of LLMs (“hallucinations”), and ethical and legislative factors.
- 17 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (20) , 3380
Open AccessArtificial Intelligence Applications in Laser-Assisted Refractive Surgery—A Comprehensive Review
Background/Objectives: Artificial Intelligence (AI) technology—in the form of Machine Learning (ML) models and other models specialized in image recognition and processing, such as Convolutional Neural Networks Visual Transformers (CNN-ViTs)—is increasingly being used in ophthalmology. This review summarizes the main AI applications for laser-assisted refractive surgery. Methods: A wide-ranging literature search on the PubMed and ISI Thompson Web of Science databases was conducted. Results: AI is an all-encompassing technological concept that refers to either specific applications of ML/CNN models, such as in keratoconus screening or diagnosis, or agentic/multimodal AI applications that process different data types using a variety of AI models. The most clinically established applications found were corneal ectasia and keratoconus screening, in which AI models can reliably exceed 95% diagnostic accuracy, specificity, and sensitivity; nomogram-derived laser ablation programming; optimization of ray-tracing calculations for ray-traced ablation profiles; patient screening and selection for refractive surgery; visual and refractive result prediction; assessment of postoperative corneal ectasia risk; detection of intraoperative complications; research on the laser coupling effect; and other applications such as monitoring eye rubbing behavior in corneal ectasia suspects. Thus, singular, specific applications of AI models have made the largest clinical contributions. These results must be interpreted with a comparison of internal versus external validation, calibration, and generalizability. Overall the technology is highly promising. Agentic/multimodal AI frameworks are currently being discussed, with pilot studies published and applicability proposed in the context of large, high-patient-volume clinical practices. The technological advent of SHAP force plot graphs and saliency maps has improved understanding of the factors that contribute mechanistically to AI model reasoning, leading to more informed clinical decisions or research applicability, such as in finding parameters or factors linked to postoperative ectasia. Conclusions: AI is already established in laser-assisted refractive surgery in the form of models specialized in data-intensive analysis. At present, the best-performing novel AI models originate from the domain of large or multi-hospital settings due to requirements for multiple latest-generation diagnostic devices, high-volume patient data, computing expertise, and resources. Future directions could include clinical standardization and trickle-down dissemination of the technology. Agentic/multimodal AI has the potential to benefit large clinical/patient settings or offer access to expert knowledge in smaller practice settings. Agentic/multimodal AI implementation is offset by challenges in complexity, the technological limitations of LLMs (“hallucinations”), and ethical and legislative factors.
- Open Access
- 28 April 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (9) , 3343
Early Real-World Clinical Outcomes and Astigmatism Vector Analysis of Toric Intraocular Lenses for High Astigmatism (≥2.0 D)
Background/Objectives: Toric intraocular lens (IOL) implantation is the standard approach for correcting corneal astigmatism during cataract surgery and refractive lens exchange (RLE). Evidence on outcomes in eyes with high corneal astigmatism (≥2.00 diopters, D), particularly in heterogeneous real-world settings, remains limited. This study evaluated visual, refractive, and astigmatic vector outcomes of toric IOL implantation in a consecutive high-astigmatism cohort and investigated predictors of residual astigmatic error. Methods: This single-center, single-surgeon retrospective analysis of prospectively collected data included 161 eyes (118 patients) with preoperative corneal astigmatism ≥ 2.00 D undergoing cataract surgery or RLE with toric IOL implantation (June 2023–December 2025). Primary outcomes at one month included visual acuity, manifest refraction, and Alpins vector analysis at the corneal plane. Secondary analyses comprised refractive stability assessment (n = 75 eyes, median seven months), comparison of astigmatic outcomes between emmetropia-targeted and intentional myopia-targeted eyes, and multivariate regression of predictors of residual astigmatic error. Results: Mean postoperative UDVA and CDVA were 0.19 ± 0.24 and 0.09 ± 0.15 logMAR, respectively. Spherical equivalent prediction error was −0.19 ± 0.42 D (69.6% within ±0.50 D of target). Mean residual cylinder was 0.52 ± 0.49 D; 62% and 88.8% of eyes achieved ≤0.50 D and ≤1.00 D, respectively. Vector analysis demonstrated a mean difference vector of 0.53 ± 0.44 D, a correction index of 1.04 ± 0.20, and near-zero centroid deviation (0.03 D @ 43°), indicating the absence of systematic directional prediction error. Refractive outcomes were stable at medium-term follow-up. Astigmatic correction accuracy was equivalent between emmetropia-targeted and intentional myopia-targeted eyes (p > 0.05 for all primary metrics). Multivariate regression identified IOL cylinder power (β = 0.051, p = 0.031) and oblique astigmatism orientation (β = 0.299 vs. WTR, p = 0.032) as independent predictors of greater residual astigmatic error. No sight-threatening complications occurred. Conclusions: Toric IOL implantation provides safe, predictable, and stable correction of high corneal astigmatism in a real-world mixed cohort. Astigmatic accuracy is maintained regardless of intended spherical refractive strategy, supporting the use of toric IOLs in highly myopic patients targeted for residual myopia. Oblique astigmatism orientation is an independent predictor of reduced correction accuracy, consistent with known limitations of current toric calculators for this meridian.
- 28 April 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (9) , 3343
Open AccessEarly Real-World Clinical Outcomes and Astigmatism Vector Analysis of Toric Intraocular Lenses for High Astigmatism (≥2.0 D)
Background/Objectives: Toric intraocular lens (IOL) implantation is the standard approach for correcting corneal astigmatism during cataract surgery and refractive lens exchange (RLE). Evidence on outcomes in eyes with high corneal astigmatism (≥2.00 diopters, D), particularly in heterogeneous real-world settings, remains limited. This study evaluated visual, refractive, and astigmatic vector outcomes of toric IOL implantation in a consecutive high-astigmatism cohort and investigated predictors of residual astigmatic error. Methods: This single-center, single-surgeon retrospective analysis of prospectively collected data included 161 eyes (118 patients) with preoperative corneal astigmatism ≥ 2.00 D undergoing cataract surgery or RLE with toric IOL implantation (June 2023–December 2025). Primary outcomes at one month included visual acuity, manifest refraction, and Alpins vector analysis at the corneal plane. Secondary analyses comprised refractive stability assessment (n = 75 eyes, median seven months), comparison of astigmatic outcomes between emmetropia-targeted and intentional myopia-targeted eyes, and multivariate regression of predictors of residual astigmatic error. Results: Mean postoperative UDVA and CDVA were 0.19 ± 0.24 and 0.09 ± 0.15 logMAR, respectively. Spherical equivalent prediction error was −0.19 ± 0.42 D (69.6% within ±0.50 D of target). Mean residual cylinder was 0.52 ± 0.49 D; 62% and 88.8% of eyes achieved ≤0.50 D and ≤1.00 D, respectively. Vector analysis demonstrated a mean difference vector of 0.53 ± 0.44 D, a correction index of 1.04 ± 0.20, and near-zero centroid deviation (0.03 D @ 43°), indicating the absence of systematic directional prediction error. Refractive outcomes were stable at medium-term follow-up. Astigmatic correction accuracy was equivalent between emmetropia-targeted and intentional myopia-targeted eyes (p > 0.05 for all primary metrics). Multivariate regression identified IOL cylinder power (β = 0.051, p = 0.031) and oblique astigmatism orientation (β = 0.299 vs. WTR, p = 0.032) as independent predictors of greater residual astigmatic error. No sight-threatening complications occurred. Conclusions: Toric IOL implantation provides safe, predictable, and stable correction of high corneal astigmatism in a real-world mixed cohort. Astigmatic accuracy is maintained regardless of intended spherical refractive strategy, supporting the use of toric IOLs in highly myopic patients targeted for residual myopia. Oblique astigmatism orientation is an independent predictor of reduced correction accuracy, consistent with known limitations of current toric calculators for this meridian.