Yi Pu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yi Pu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Boya Wang
China Academy of Building Research 1 , Beijing 100013
3 shared publicationsLiping Qiu
China Academy of Building Research 1 , Beijing 100013
3 shared publicationsCheng Guo
2 shared publicationsGuozhu Li
2 shared publicationsLi Zhao
2 shared publicationsQingqin Wang
2 shared publications
Latest Publications
- 1 September 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (9)
Flow topology and multi-source contaminant transport in a compounding room under different ventilation strategies
The preparation of antineoplastic drugs in pharmacy intravenous admixture services may generate hazardous particulate contaminants. However, the fluid-dynamic mechanisms governing their transport at the room scale remain difficult to predict. In this study, computational fluid dynamics, Lagrangian particle tracking, and Liutex-based vortex identification were employed to investigate airflow organization, vortex evolution, and particle transport in a hospital compounding room. At 42 ACH, the optimized S-3 configuration used 19.2% less ventilation airflow than the conventional S-6 configuration at 52 ACH. Nevertheless, S-3 achieved a comparable total contaminant removal index at 120 s (99.25% vs 99.17%). Compared with S-6, S-3 increased the proportion of regions with an air age below 60 s by 26.5% and air change efficiency by 48.5%. It also reduced the concentration distribution index by 51.2%. Liutex analysis showed that coherent vortices promoted particle retention and contaminant recirculation near occupied zones. Optimized vent placement weakened these structures and transformed contaminant transport from a recirculation-dominated mode into directional removal. These findings reveal the intrinsic linkage between airflow organization, vortex evolution, and contaminant transport and provide a mechanistic basis for contamination control and ventilation design in healthcare clean environments.
- 1 September 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (9)
Flow topology and multi-source contaminant transport in a compounding room under different ventilation strategies
The preparation of antineoplastic drugs in pharmacy intravenous admixture services may generate hazardous particulate contaminants. However, the fluid-dynamic mechanisms governing their transport at the room scale remain difficult to predict. In this study, computational fluid dynamics, Lagrangian particle tracking, and Liutex-based vortex identification were employed to investigate airflow organization, vortex evolution, and particle transport in a hospital compounding room. At 42 ACH, the optimized S-3 configuration used 19.2% less ventilation airflow than the conventional S-6 configuration at 52 ACH. Nevertheless, S-3 achieved a comparable total contaminant removal index at 120 s (99.25% vs 99.17%). Compared with S-6, S-3 increased the proportion of regions with an air age below 60 s by 26.5% and air change efficiency by 48.5%. It also reduced the concentration distribution index by 51.2%. Liutex analysis showed that coherent vortices promoted particle retention and contaminant recirculation near occupied zones. Optimized vent placement weakened these structures and transformed contaminant transport from a recirculation-dominated mode into directional removal. These findings reveal the intrinsic linkage between airflow organization, vortex evolution, and contaminant transport and provide a mechanistic basis for contamination control and ventilation design in healthcare clean environments.
- Open Access
- 22 April 2026
- Published by Elsevier in SSRN Electronic Journal
Policy-driven multi-objective optimization of integrated energy systems for a small-scale nearly zero-energy office building
In response to the continuous refinement of distributed renewable energy policies, the optimal energy system configuration for small-scale nearly zero-energy office buildings remains uncertain. This study investigates a representative building in Qingdao, China, and evaluates the applicability of photovoltaic (PV) and their coupling with energy storage technologies, including electrochemical and hydrogen energy storage, from the perspective of building owners under varying revenue-cost scenarios. To this end, a total of 20 representative scenarios were constructed and a coupled TRNSYS–NSGA-II framework was employed to perform multi-objective optimization. The optimal system configurations were subsequently identified through economic feasibility screening and the equal-weight ideal point method. The findings indicate that policy-induced fluctuations in revenue exert variable impacts on the optimal solutions. Under conditions of low or high cost, the influence is relatively limited. However, as system costs approach the local baseline level, revenue variations significantly reshape the boundaries of system decisions. Meanwhile, PV coupled with electrochemical storage dominates in most scenarios. Conversely, hydrogen energy systems have yet to demonstrate practical competitiveness, and its future potential is strongly dependent on coordinated cost reductions in both PV and hydrogen-related technologies.
- 22 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPolicy-driven multi-objective optimization of integrated energy systems for a small-scale nearly zero-energy office building
In response to the continuous refinement of distributed renewable energy policies, the optimal energy system configuration for small-scale nearly zero-energy office buildings remains uncertain. This study investigates a representative building in Qingdao, China, and evaluates the applicability of photovoltaic (PV) and their coupling with energy storage technologies, including electrochemical and hydrogen energy storage, from the perspective of building owners under varying revenue-cost scenarios. To this end, a total of 20 representative scenarios were constructed and a coupled TRNSYS–NSGA-II framework was employed to perform multi-objective optimization. The optimal system configurations were subsequently identified through economic feasibility screening and the equal-weight ideal point method. The findings indicate that policy-induced fluctuations in revenue exert variable impacts on the optimal solutions. Under conditions of low or high cost, the influence is relatively limited. However, as system costs approach the local baseline level, revenue variations significantly reshape the boundaries of system decisions. Meanwhile, PV coupled with electrochemical storage dominates in most scenarios. Conversely, hydrogen energy systems have yet to demonstrate practical competitiveness, and its future potential is strongly dependent on coordinated cost reductions in both PV and hydrogen-related technologies.