Chris Hollen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chris Hollen has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Christopher C. Hemond
Neurology, University of Massachusetts Chan Medical School, Worcester, USA
2 shared publications - Elizabeth Silbermann
Neurology, Oregon Health & Science University, Portland, USA
2 shared publications Andrew J. Solomon
Neurological Sciences, UVM Larner College of Medicine, Burlington, VT, USA
1 shared publicationCarolina Garcia
Department of Neurology, Oregon Health & Science University, Portland, OR, USA; Portland VA Medical Center, Portland, OR, USA
1 shared publicationCole Crowson
Department of Neurology, Oregon Health & Science University, Portland, OR, USA; Portland VA Medical Center, Portland, OR, USA
1 shared publication- Dennis Bourdette
Neurology, Oregon Health & Science University, Portland, USA
1 shared publication
Latest Publications
- 22 August 2026
- Published by SAGE Publications in Multiple Sclerosis Journal
Implementation of a pilot online educational program to identify paramagnetic rim lesions
Background: Paramagnetic rim lesions are a highly specific magnetic resonance imaging biomarker for multiple sclerosis now incorporated into the 2024 McDonald Criteria. However, paramagnetic rim lesion identification remains underutilized in clinical practice. This study evaluates the effectiveness of an online, educational platform for improving paramagnetic rim lesion identification. Design/methods: We conducted a prospective pre-post intervention study using a web-based, asynchronous educational platform. The intervention included baseline assessment, didactic education on paramagnetic rim lesion identification, interactive case-based learning with 10 examples, and post-intervention assessment. The primary efficacy endpoint was ⩾80% of participants achieving ⩾80% accuracy on post-intervention assessment. Wilcoxon signed-rank test was used to compare pre- and post-intervention scores. Results: A total of 182 participants completed the educational intervention. The proportion of respondents achieving the primary efficacy endpoint increased from 65% (n = 118) to 91% (n = 166) (McNemar’s χ 2 = 36.8, p < 0.001). Mean accuracy scores improved significantly from 3.84 ± 0.85 (76.8%) to 4.39 ± 0.77 (87.8%) correct responses out of 5 (mean difference = 0.55 points, 95% confidence interval = [0.43, 0.67], p < 0.001). Conclusions: In this pilot study, an interactive web-based educational platform improved healthcare providers’ ability to identify paramagnetic rim lesions, with 91% achieving target proficiency. This scalable approach can facilitate broader implementation of the 2024 McDonald Criteria in clinical practice.
- 22 August 2026
- Published by SAGE Publications in Multiple Sclerosis Journal
Implementation of a pilot online educational program to identify paramagnetic rim lesions
Background: Paramagnetic rim lesions are a highly specific magnetic resonance imaging biomarker for multiple sclerosis now incorporated into the 2024 McDonald Criteria. However, paramagnetic rim lesion identification remains underutilized in clinical practice. This study evaluates the effectiveness of an online, educational platform for improving paramagnetic rim lesion identification. Design/methods: We conducted a prospective pre-post intervention study using a web-based, asynchronous educational platform. The intervention included baseline assessment, didactic education on paramagnetic rim lesion identification, interactive case-based learning with 10 examples, and post-intervention assessment. The primary efficacy endpoint was ⩾80% of participants achieving ⩾80% accuracy on post-intervention assessment. Wilcoxon signed-rank test was used to compare pre- and post-intervention scores. Results: A total of 182 participants completed the educational intervention. The proportion of respondents achieving the primary efficacy endpoint increased from 65% (n = 118) to 91% (n = 166) (McNemar’s χ 2 = 36.8, p < 0.001). Mean accuracy scores improved significantly from 3.84 ± 0.85 (76.8%) to 4.39 ± 0.77 (87.8%) correct responses out of 5 (mean difference = 0.55 points, 95% confidence interval = [0.43, 0.67], p < 0.001). Conclusions: In this pilot study, an interactive web-based educational platform improved healthcare providers’ ability to identify paramagnetic rim lesions, with 91% achieving target proficiency. This scalable approach can facilitate broader implementation of the 2024 McDonald Criteria in clinical practice.
- 26 April 2026
- Published by SAGE Publications in Multiple Sclerosis Journal
- Vol. 32 (6) , 634-641
Filtered-phase imaging versus susceptibility-weighted imaging for paramagnetic rim lesion detection in multiple sclerosis: A head-to-head comparison
Background: Paramagnetic rim lesions (PRLs) detected on susceptibility-sensitive magnetic resonance imaging (MRI) represent chronic active lesions and correlate with disease progression in multiple sclerosis (MS). However, optimal detection methods remain unclear. Objective: To compare PRL detection using filtered-phase imaging versus susceptibility-weighted imaging (SWI) and assess inter-rater reliability among clinical neuroimmunologists. Methods: We retrospectively analyzed 3T MRI from 44 relapsing-remitting MS patients. Four neurologists with neuroimmunology training received 30-minute training sessions and evaluated PRLs on both filtered-phase and SWI sequences. Consensus adjudication resolved discordant ratings and served as the reference standard for calculating diagnostic accuracy. Results: PRLs were identified in 21/44 patients (48%). Relative to consensus as the reference standard, SWI demonstrated higher sensitivity than filtered-phase imaging (66.0% vs. 60.4%), while filtered phase showed superior positive predictive value (0.903 vs. 0.714). Both sequences achieved very high specificity (>97%). Inter-rater reliability was good for SWI (Intraclass Correlation Coefficient [ICC] = 0.85) and moderate for filtered phase (ICC = 0.71) for per-subject PRL counts. Vascular complexity was the most common cause of false-positive identification (65% of cases). Conclusions: Both techniques reliably detect PRLs with substantial inter-rater agreement. Filtered-phase imaging offers superior positive predictive value, while SWI provides better sensitivity and inter-rater reliability. Further development of a standardized training program for assessment of PRL and studies directly comparing susceptibility-sensitive sequences on different vendor platforms are warranted.
- 26 April 2026
- Published by SAGE Publications in Multiple Sclerosis Journal
- Vol. 32 (6) , 634-641
Filtered-phase imaging versus susceptibility-weighted imaging for paramagnetic rim lesion detection in multiple sclerosis: A head-to-head comparison
Background: Paramagnetic rim lesions (PRLs) detected on susceptibility-sensitive magnetic resonance imaging (MRI) represent chronic active lesions and correlate with disease progression in multiple sclerosis (MS). However, optimal detection methods remain unclear. Objective: To compare PRL detection using filtered-phase imaging versus susceptibility-weighted imaging (SWI) and assess inter-rater reliability among clinical neuroimmunologists. Methods: We retrospectively analyzed 3T MRI from 44 relapsing-remitting MS patients. Four neurologists with neuroimmunology training received 30-minute training sessions and evaluated PRLs on both filtered-phase and SWI sequences. Consensus adjudication resolved discordant ratings and served as the reference standard for calculating diagnostic accuracy. Results: PRLs were identified in 21/44 patients (48%). Relative to consensus as the reference standard, SWI demonstrated higher sensitivity than filtered-phase imaging (66.0% vs. 60.4%), while filtered phase showed superior positive predictive value (0.903 vs. 0.714). Both sequences achieved very high specificity (>97%). Inter-rater reliability was good for SWI (Intraclass Correlation Coefficient [ICC] = 0.85) and moderate for filtered phase (ICC = 0.71) for per-subject PRL counts. Vascular complexity was the most common cause of false-positive identification (65% of cases). Conclusions: Both techniques reliably detect PRLs with substantial inter-rater agreement. Filtered-phase imaging offers superior positive predictive value, while SWI provides better sensitivity and inter-rater reliability. Further development of a standardized training program for assessment of PRL and studies directly comparing susceptibility-sensitive sequences on different vendor platforms are warranted.