YMYusuke Morimitsu

Yusuke Morimitsu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yusuke Morimitsu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimization of the reconstruction kernel for temporal bone imaging using photon-counting detector CT: A combined physical and visual evaluation

    by S. Nishii, T. Asahara, Y. Morimitsu, S. Kajisaki, N. Akagi, M. Honda, H. Hayashi, A. Sugaya, K. Munetomo, F. Higaki, et al.


  • Open Access

    Applicability of Effective Atomic Number (Z eff) Image Analysis of Coronary Plaques Measured With Photon- Counting Computed Tomography

    by Takashi Asahara, Mana Mitani, Natsumi Kimoto, Rina Nishigami, Kazuki Takegami, Yusuke Morimitsu, Noriaki Akagi, Toru Miyoshi, Yuki Kanazawa, Toshihiro Iguchi, et al.

    Objective: Coronary computed tomography (CT) allows the assessment of cardiovascular risk by imaging calcified plaques in coronary arteries. Because photon-counting CT (PC-CT) can analyze the effective atomic number (Z eff) of the subject, it is expected to be applied to the analysis of plaque components. The purpose of this study was to investigate the applicability of plaque analysis based on Z eff images with continuous gradation. Methods: Z eff images were generated from virtual monoenergetic images (VMIs) obtained by PC-CT. Z eff values were derived from the difference between linear attenuation coefficients (μ) at low and high energies using an in-house program. Coronary CT images of 64 plaques in 10 patients were analyzed. The Z eff score, calculated as the sum of Z eff values within the plaque region, was calculated and compared with the conventional Agatston score and mean coronary artery calcium (CAC) score. Results: The systematic uncertainty of Z eff images was estimated to be ±0.08. The Z eff score of actual patient data showed strong positive correlations with the conventional Agatston and mean CAC scores. The Z eff score uses all voxel data in the plaque area, whereas conventional scores consider only data from voxels with a CT value >130. We found that the conventional scores excluded 39% of the plaque area, and the Z eff score permitted the analysis of low- and high-density plaques. Conclusions: Z eff imaging was shown to be applicable to plaque analysis that reflects the entire plaque volume. This study demonstrated its technical feasibility as a compositional analysis method using the Z eff image.