LWLingyun Wang

Lingyun Wang

*This is an algorithmically generated author record based on publicly available information.

Lingyun Wang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Wellbore Stability Assessment of the Luzhou Block Shale Gas Reservoir Based on Mogi–Coulomb–Jaeger Failure Assessment Model

    by Zhihui Wang, Xuecheng Dong, Yi Sun, Lingyun Wang, Junrui Li

    During deep shale gas development, complex in situ stress conditions, abnormal formation pressure, and well-developed bedding planes result in complicated wellbore instability mechanisms. Conventional homogeneous rock models are unable to accurately characterize the different failure behaviors between matrix failure and bedding-plane slip. To address this issue, a Mogi–Coulomb and Jaeger-based multi-mechanism failure assessment model was developed for the Longmaxi shale gas reservoir in the Luzhou Block by integrating logging data, core experiments, and field drilling information. The results show that bedding structures significantly control rock strength and wellbore failure modes. The proposed model effectively identifies different failure mechanisms, including matrix shear failure, bedding slip, and tensile failure. Furthermore, the effects of well inclination, azimuth, and bedding angle on collapse pressure were analyzed, and well azimuth was found to have the greatest influence on the safe drilling window. This study reveals the controlling role of matrix–weak-plane strength contrast in shale wellbore instability and provides theoretical support for well trajectory optimization and drilling parameter design in deep shale gas development.

  • Open Access

    Comparability of Archived Aging-Stage and Retest Records from Miniature Temperature–Pressure Sensors: Rank, Concordance, and Response Shape

    by Zhiyuan Zhou, Xuecheng Dong, Liangzhu Yan, Lingyun Wang

    Archived sensor records often lack synchronized reference pressure, making it necessary to distinguish retained device ordering from numerical agreement and response-shape reproduction. Aging-stage and first-retest records from 22 miniature temperature–pressure sensors were evaluated using marginal features, Spearman rank correlation, Lin’s concordance correlation coefficient (CCC), device-level bootstrap intervals, and 56 equally weighted common-temperature bins. A disjoint 16-device same-mode cohort tested recurrence of marginal-feature ordering. The analysis demonstrates the following. The fifth percentile retained device order (0.886) and identity-line agreement (CCC 0.968); standard deviation retained order (0.648) without agreement (CCC 0.032), which the decomposition attributes to systematic displacement (accuracy factor 0.077), whereas the 95th percentile (CCC 0.379) is precision-limited (Pearson r 0.510). Common-temperature alignment reversed the raw-median difference for every device. Relative temperature-slope retention was negligible (rank correlation 0.013), and complete centered-profile correlation was heterogeneous (median 0.356). Lower-tail, upper-tail, and dispersion ordering recurred in the disjoint cohort. The article proposes a multilevel retention signature, an ordinal pattern read across evidence levels, together with candidate retest endpoints. Calibration accuracy, sensor life, sensitivity degradation, retention of metrological characteristics, and causal aging lie beyond this evidence.

  • Open Access

    Real-Time Lexicographic MPC with Online Correction for Intelligent Drill-Bit Rotary Valves in Mud-Pulse Telemetry

    by Xuecheng Dong, Liangzhu Yan, Lingyun Wang, Zhiyuan Zhou, Youyan Jian, Run Li

    Reliable front-end pressure-pulse generation is critical to mud-pulse telemetry because waveform distortion introduced at the rotary valve propagates through the telemetry chain and reduces downstream recoverability. This paper targets accurate and computationally tractable control of an intelligent drill-bit rotary valve under actuator limits, parameter drift, and downhole-like disturbances. A control-oriented electromechanical–hydraulic grey-box model is established, and a real-time lexicographic model predictive control (MPC) framework with candidate pre-screening, move blocking, and online correction/compensation is developed and compared with proportional–integral–derivative (PID) control and conventional MPC. Under a sampling period of Ts=20ms, the proposed controller reduces the step-tracking rise time from 2.18s to 1.76s and the steady-state pressure error from 0.1208MPa to 0.0292MPa relative to conventional MPC. In the pulse-output and mismatch–disturbance scenarios, it further maintains lower steady-state pressure error while reducing the cumulative input variation from 51.0 to 11.5 and from 121.5 to 19.5, respectively. The observed 99th-percentile and worst-case MATLAB workstation execution times remain below one sampling period, while supplementary mismatch–disturbance sensitivity maps indicate a favorable accuracy–timing compromise within the tested numerical envelope. These results support the proposed method as a simulation-validated candidate for low-complexity rotary-valve control and motivate subsequent bench/hardware-in-the-loop (HIL) validation rather than field-qualified deployment claims.


  • Open Access

    Surface-Gradient Design of PDC Cutter Chamfers with a SiC Interlayer, Nanodiamond Topcoat, and Shallow Cobalt Leaching: Effects on Residual Stress, Wear, Impact Spalling, and Bench-Scale Signal Separability

    by Xuecheng Dong, Liangzhu Yan, Lingyun Wang, Zhiyuan Zhou, Youyan Jian, Yahang Zhou

    Deep hard-rock and geothermal drilling expose polycrystalline diamond compact (PDC) cutter chamfers to coupled thermal shock, abrasive wear, and intermittent impact, which accelerates edge spalling and degrades the quality of on-bit monitoring signals. This bench-scale proof-of-concept study evaluates a surface-gradient architecture that combines shallow cobalt leaching in the chamfer region with a thin silicon carbide (SiC) interlayer and a nanocrystalline diamond topcoat. Commercial 13 mm PDC cutters were treated within a surface-gradient design window of tSiC = 0–1.0 μm and LdeCo = 0–200 μm, and were examined by cross-sectional microscopy, XPS/ToF-SIMS, Raman stress mapping, scratch adhesion, apparent fracture toughness, laser-flash thermal transport, thermal-shock cycling, 400 °C pin-on-disc wear, instrumented impact loading, bench granite-drilling signal acquisition, and finite-element correlation. The optimized configuration (tSiC≈0.7μm, tD≈5μm, and LdeCo≈100μm) reduced the 95th-percentile tensile residual stress at the chamfer from about 0.48 to 0.26 GPa, reached a scratch critical load of about 28 N, compared with about 16 N for the topcoat-only condition and about 25 N for the SiC-plus-topcoat condition, cut high-temperature wear volume by about 40%, and shifted the characteristic spalling energy from about 0.8 to 1.3 J. In bench-scale granite drilling, the same design stabilized frictional response and improved simple pre-spall discrimination metrics, raising ROC-AUC from about 0.65 to 0.87. These bench-scale results provide proof-of-concept evidence that surface-gradient design can improve PDC chamfer durability and signal discriminability, while the proposed signal metrics have yet to be validated under field-scale downhole conditions.