LGLiangtao Gu

Liangtao Gu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Liangtao Gu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Wuwei Ren

    ShanghaiTech University

    2 shared publications
  • Chen Duan

    School of Information Science and Technology, ShanghaiTech University, Shanghai 201210, China

    1 shared publication
  • Guoyan Zheng

    Institute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China

    1 shared publication
  • Hao Chen

    State Key Laboratory of Chemical Biology Molecular Imaging Center Shanghai Institute of Materia Medica Chinese Academy of Sciences Shanghai China

    1 shared publication
  • Jiale Wang

    Institute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China

    1 shared publication
  • Jonathan Dong

    École Polytechnique Fédérale de Lausanne Lausanne Switzerland

    1 shared publication

Latest Publications

  • Open Access

    Multi-parametric NIR-II fluorescence perfusion imaging towards quantitative stroke evaluation

    by Liangtao Gu, Zhao Fang, Chen Duan, Yu Zhang, Xieyang Bian, Xinning Sun, Jiale Wang, Peixi Peng, Yanan Wu, Tinghua Wen, et al.

    Preclinical stroke research is severely hampered by the lack of high-throughput, quantitative perfusion imaging tools capable of bridging the gap between functional hemodynamics and structural injury. The emerging second near-infrared (NIR-II) fluorescence imaging offers superior spatial resolution and tissue penetration, but its utility remains restricted by a lack of standardized analysis protocols and inability to resolve in-depth infarct regions. Here, we introduce FIMPA, an integrated analytical framework for standardized, multi-parametric stroke evaluation based on NIR-II fluorescence perfusion imaging. FIMPA systematically processes the image sequence through motion correction and atlas registration to generate an anatomically aligned library of 125 vascular and hemodynamic parameters. Statistical screening identifies 67 stroke-correlated features, enabling objective, data-driven quantification of perfusion deficits. To resolve spatial infarct boundaries, we developed FIMPA-SI (FIMPA Stroke Index), a deep learning-based index utilizing a ViT-UNETR framework. By leveraging self-supervised pre-training with MRI data, FIMPA-SI suppresses dominant vascular signals to translate multi-parametric dynamics into anatomically precise stroke severity maps. Validated in tMCAO mice, FIMPA-SI achieves high spatial concordance with MRI and significantly outperforms conventional laser speckle contrast imaging and single-parameter metrics. FIMPA provides a robust solution for accelerating preclinical therapeutics and advancing optical neuroimaging.

  • High‐Fidelity Miniature Fluorescence Microscopy Using Zernike‐Based Point‐Spread‐Function Modeling and Hardware‐Assisted Calibration

    by Liangtao Gu, Yan Liu, Xinyi Zhu, Rui Li, Ning Zhou, Jonathan Dong, Wuwei Ren

    Miniature fluorescence microscopy (Miniscope) enables critical observation of neural dynamics in freely behaving animals. However, its simplified optical design inherently limits spatial resolution and introduces significant background fluorescence, constraining image fidelity. To address these challenges, we present MiniZSV, a universal and practical image enhancement pipeline comprising background removal, Zernike‐polynomial‐based point‐spread‐function (PSF) modeling, and spatially‐varying deconvolution. Our pipeline leverages Zernike polynomial to represent an accurate spatially‐varying PSF map based on experimental data acquired by an open‐source Miniscope toolkit, ensuring high signal‐to‐noise ratio (SNR) reconstructions beyond conventional approaches. Applied to in vivo calcium imaging and angiography, MiniZSV uncovers low‐SNR neurons and overlapping vascular structures, significantly improving neuron extraction and hemodynamic analysis beyond the limits of raw Miniscope data. By providing higher‐fidelity imaging data, MiniZSV facilitates more accurate and versatile downstream analyses in neurobiology and advances the potential of Miniscope technology.