RZRunzhi Zhang

Runzhi Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Runzhi Zhang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    5T Non-Contrast One-Stop MRA for Thoracic Aorta and Coronary Arteries: A Prospective Feasibility Study in Healthy Volunteers

    by Yan Xu, Chuangwei Wei, Runzhi Zhang, Jiahuan Dai, Hui Xu, Ke Xue, Nan Zhang, Jiayi Liu, Lei Xu, Zhaoying Wen

    Background/Objectives: This prospective study evaluated the feasibility of a non-contrast 5T one-stop MRA protocol for simultaneous assessment of the thoracic aorta and coronary arteries and examined the effect of heart rate (HR) on image quality. Methods: Thirty-four healthy volunteers underwent 5T MRA and were stratified by median HR into Low-HR (≤70 bpm, n = 17) and High-HR (>70 bpm, n = 17) groups. Subjective image quality was assessed using a 4-point scale, and signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and vessel edge sharpness (VES) were measured in predefined aortic and proximal coronary segments. Results: The protocol was successfully completed in all participants, and all evaluated segments were evaluable. Interobserver and intraobserver agreement was excellent (kappa ≥ 0.90; ICC ≥ 0.85). Subjective aortic scores did not differ between HR groups, whereas several coronary segments had lower scores in the High-HR group. SNR, CNR, and VES were higher in the Low-HR group across all objectively assessed segments. Conclusions: These findings support the technical feasibility of integrated 5T non-contrast MRA in healthy volunteers and suggest that the subjective effect of higher HR is more evident in the coronary arteries than in the thoracic aorta, warranting further validation in patients with cardiovascular disease.

  • Open Access

    Comparison of Non-Contrast Coronary MRA Image Quality at 5T and 3T Based on the SCCT Segmental Model: A Technical Feasibility Study in Healthy Volunteers

    by Chuangwei Wei, Yan Xu, Runzhi Zhang, Wenjing Zhao, Nan Zhang, Jiayi Liu, Lei Xu, Zhaoying Wen

    Background: This study aimed to evaluate the image quality of non-contrast-enhanced whole-heart coronary MR angiography (CMRA) using three different sequences: coronal-plane balanced turbo field echo (BTFE) at 3T, axial-plane modified Dixon (mDixon) at 3T, and axial-plane mDixon at 5T. Methods: Healthy young volunteers were prospectively enrolled from January 2025 to April 2025. Each participant underwent three CMRA scans—3T BTFE, 3T mDixon, and 5T mDixon—using customized MR protocols, all performed within 48 h. Subjective image quality was assessed based on the society of cardiovascular computed tomography 18-segment model using a four-point scale (1 = non-assessable to 4 = excellent). The assessability rate was defined as the percentage of segments receiving a score ≥ 2. Objective evaluation of the main coronary arteries included measurements of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel edge sharpness (VES), and visible vessel length. The Friedman test and one-way repeated measures analysis of variance (ANOVA) were performed to compare parameters obtained from 3T BTFE, 3T mDixon, and 5T mDixon. Results: A total of 20 participants (10 men; mean age, 24 ± 2 years) were included. Both 5T mDixon and 3T BTFE showed more favorable subjective image quality than 3T mDixon, particularly in distal and branch-level coronary segments. All three sequences achieved high vessel assessability. Quantitatively, 5T mDixon provided the highest SNR and CNR, while 3T BTFE showed the highest VES. Visible vessel lengths in LAD and RCA were longer with 5T mDixon and 3T BTFE versus 3T mDixon. However, 5T mDixon required the longest acquisition time (12.55 ± 2.80 min), consistent with its higher spatial resolution. Conclusions: In conclusion, in healthy volunteers, both 5T mDixon and 3T BTFE outperformed 3T mDixon in non-contrast CMRA, particularly in distal and branch-level coronary segments. While 5T mDixon provided the highest SNR and CNR, 3T BTFE achieved the greatest VES. These findings support the technical feasibility of both approaches, but further studies in patients are needed to confirm their clinical applicability