Ali Ibrahim Shkhair
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ali Ibrahim Shkhair has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Susan Varghese
Department of Chemistry, School of Physical and Mathematical Sciences, University of Kerala, Kariavattom Campus, Thiruvananthapuram-695581, Kerala, India
40 shared publicationsGreeshma Rajeevan
Department of Chemistry, School of Physical and Mathematical Sciences, University of Kerala, Kariavattom Campus, Thiruvananthapuram-695581, Kerala, India
35 shared publications- Sony George
Department of Chemistry, School of Physical and Mathematical Sciences, University of Kerala, Kariavattom Campus, Thiruvananthapuram-695581, Kerala, India
34 shared publications Anju S. Madanan
Department of Chemistry, School of Physical and Mathematical Sciences, University of Kerala, Kariavattom Campus, Thiruvananthapuram-695581, Kerala, India
31 shared publicationsGeneva Indongo
Department of Chemistry, School of Physical and Mathematical Sciences, University of Kerala, Kariavattom Campus, Thiruvananthapuram-695581, Kerala, India
30 shared publicationsMerin K. Abraham
Department of Chemistry, School of Physical and Mathematical Sciences, University of Kerala, Kariavattom Campus, Thiruvananthapuram-695581, Kerala, India
30 shared publications
Latest Publications
- 5 May 2026
- Published by Springer Nature in Journal of Fluorescence
- Vol. 36 (5) , 3523-3536
Development of a Europium Molybdate Complex Luminescent Platform as a “Turn-off” Sensing Detection of Bilirubin: A Liver Function Biomarker
High-sensitivity luminescence nanoprobes for biomolecule identification are important in clinical diagnostics and biological analysis. Since bilirubin is a key indicator of liver function, early and accurate detection is essential for diagnosing and monitoring liver disease. In this study, we developed a red-light-emitting Europium (Eu) molybdate complex using a single-step, room-temperature technique, exhibiting unique photostability. When the bilirubin is added, a decrease in the luminescence of the synthesized Eu-molybdate complex is observed in a linear range of 9.96 to 58.8 µM. The detection limit and quantification limit were calculated to be 0.211 µM and 0.76 µM, respectively. The nanoprobe we developed exhibits exceptional selectivity and sensitivity to bilirubin, even in the presence of other biomolecules and ions. Furthermore, bilirubin can be measured in both blood and urine using this method. Graphical Abstract The alternative text for this image may have been generated using AI.
- 5 May 2026
- Published by Springer Nature in Journal of Fluorescence
- Vol. 36 (5) , 3523-3536
Development of a Europium Molybdate Complex Luminescent Platform as a “Turn-off” Sensing Detection of Bilirubin: A Liver Function Biomarker
High-sensitivity luminescence nanoprobes for biomolecule identification are important in clinical diagnostics and biological analysis. Since bilirubin is a key indicator of liver function, early and accurate detection is essential for diagnosing and monitoring liver disease. In this study, we developed a red-light-emitting Europium (Eu) molybdate complex using a single-step, room-temperature technique, exhibiting unique photostability. When the bilirubin is added, a decrease in the luminescence of the synthesized Eu-molybdate complex is observed in a linear range of 9.96 to 58.8 µM. The detection limit and quantification limit were calculated to be 0.211 µM and 0.76 µM, respectively. The nanoprobe we developed exhibits exceptional selectivity and sensitivity to bilirubin, even in the presence of other biomolecules and ions. Furthermore, bilirubin can be measured in both blood and urine using this method. Graphical Abstract The alternative text for this image may have been generated using AI.
- 28 December 2025
- Published by Springer Nature in Plasmonics
- Vol. 21 (2) , 1659-1669
A Hydrazone-based Fluorescent turn-off Sensor for Highly Selective and Sensitive Detection of Iron (III) in Aqueous Media
- 28 December 2025
- Published by Springer Nature in Plasmonics
- Vol. 21 (2) , 1659-1669
A Hydrazone-based Fluorescent turn-off Sensor for Highly Selective and Sensitive Detection of Iron (III) in Aqueous Media
- Open Access
- 3 November 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (22) , 5111-5112
Correction: Quantum dot-to-dye-based fluorescent ratiometric immunoassay for GFAP: a biomarker for ischaemic stroke and glioblastoma multiforme
Correction for ‘Quantum dot-to-dye-based fluorescent ratiometric immunoassay for GFAP: a biomarker for ischaemic stroke and glioblastoma multiforme’ by Susan Varghese et al. , Analyst , 2025, 150 , 329–341, https://doi.org/10.1039/D4AN01292E.
- 3 November 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (22) , 5111-5112
Open AccessCorrection: Quantum dot-to-dye-based fluorescent ratiometric immunoassay for GFAP: a biomarker for ischaemic stroke and glioblastoma multiforme
Correction for ‘Quantum dot-to-dye-based fluorescent ratiometric immunoassay for GFAP: a biomarker for ischaemic stroke and glioblastoma multiforme’ by Susan Varghese et al. , Analyst , 2025, 150 , 329–341, https://doi.org/10.1039/D4AN01292E.
- 7 April 2025
- Published by Springer Nature in Journal of Fluorescence
- Vol. 35 (10) , 9971-9982
Erlotinib-Conjugated O-Phenylenediamine Derived Fluorescent Carbon Nanodots (OPD@CD) Platform for Targeting Breast Cancer (MCF-7) Cells
Breast cancer continues to be a complicated and pervasive health issue that impacts women worldwide. Fluorescent nanoparticles, in particular, provide significant potential for imaging and drug delivery in cancer cells. We describe the utilization of o-phenylenediamine carbon nanodots (OPD@CD) as fluorescent agents for in vitro imaging and drug delivery of breast cancer cells. The surface of OPD@CD was modified with the tyrosine kinase inhibition anticancer drug - erlotinib. The drug specifically targets human breast cancer cell lines (MCF-7) that overexpress the epidermal growth factor receptor (EGFR). The confocal luminescence microscopic photographs exhibit sufficient luminescence staining in MCF-7 cells.
- 7 April 2025
- Published by Springer Nature in Journal of Fluorescence
- Vol. 35 (10) , 9971-9982
Erlotinib-Conjugated O-Phenylenediamine Derived Fluorescent Carbon Nanodots (OPD@CD) Platform for Targeting Breast Cancer (MCF-7) Cells
Breast cancer continues to be a complicated and pervasive health issue that impacts women worldwide. Fluorescent nanoparticles, in particular, provide significant potential for imaging and drug delivery in cancer cells. We describe the utilization of o-phenylenediamine carbon nanodots (OPD@CD) as fluorescent agents for in vitro imaging and drug delivery of breast cancer cells. The surface of OPD@CD was modified with the tyrosine kinase inhibition anticancer drug - erlotinib. The drug specifically targets human breast cancer cell lines (MCF-7) that overexpress the epidermal growth factor receptor (EGFR). The confocal luminescence microscopic photographs exhibit sufficient luminescence staining in MCF-7 cells.
- 5 February 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (8) , 1850-1859
Near infrared-emitting carbon dots for the detection of glial fibrillary acidic protein (GFAP): a non-enzymatic approach for the early identification of stroke and glioblastoma
Immunoassay techniques are widely recognized for their sensitivity and selectivity in biomarker detection; however, their high cost, time-consuming protocols and limited stability often pose significant limitations. In this study, we address these challenges by developing an antibody-free fluorescent platform for the detection of glial fibrillary acidic protein (GFAP), a biomarker released from astrocytes, which plays a critical role in neurological diseases such as ischemic stroke and glioblastoma (GBM). Glutamic acid (GA), a neurotransmitter prevalent in the brain, was selected to quench a near-infrared (NIR) emitting carbon dot-based probe, exploiting the potential interaction between GA and GFAP. The probe demonstrated a turn-on response towards GFAP in the presence of various co-existing biomolecules and ions with a detection limit of 1.8 pg mL−1. A real sample assay conducted in human serum further validated the performance of the probe, achieving a recovery rate of 85% to 97%, underscoring the potential of the probe as a reliable and cost-effective tool for GFAP detection in clinical settings.
- 5 February 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (8) , 1850-1859
Near infrared-emitting carbon dots for the detection of glial fibrillary acidic protein (GFAP): a non-enzymatic approach for the early identification of stroke and glioblastoma
Immunoassay techniques are widely recognized for their sensitivity and selectivity in biomarker detection; however, their high cost, time-consuming protocols and limited stability often pose significant limitations. In this study, we address these challenges by developing an antibody-free fluorescent platform for the detection of glial fibrillary acidic protein (GFAP), a biomarker released from astrocytes, which plays a critical role in neurological diseases such as ischemic stroke and glioblastoma (GBM). Glutamic acid (GA), a neurotransmitter prevalent in the brain, was selected to quench a near-infrared (NIR) emitting carbon dot-based probe, exploiting the potential interaction between GA and GFAP. The probe demonstrated a turn-on response towards GFAP in the presence of various co-existing biomolecules and ions with a detection limit of 1.8 pg mL−1. A real sample assay conducted in human serum further validated the performance of the probe, achieving a recovery rate of 85% to 97%, underscoring the potential of the probe as a reliable and cost-effective tool for GFAP detection in clinical settings.
- 27 December 2024
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 8 (1) , 835-843
Bovine Serum Albumin-Capped Fluorescent Copper Nanocluster Incorporated with 2D-Molybdenum Disulfide Nanosheets as a FRET-Based Immune Probe for the “Turn-On” Detection of cTnT
Cardiovascular disease is the primary cause of mortality worldwide, as stated by the World Health Organization. We utilized the red fluorescence emitted by copper nanoclusters (CuNCs) to detect cardiac Troponin T (cTnT). We designed a fluorescent probe to detect cTnT using an on-off-on technique. The cTnT antibody was coupled on the surface of a bovine serum albumin-capped CuNC (Ab-BSA©CuNC) MoS2 nanosheet, efficiently quenching the luminescence of Ab-BSA©CuNCs due to their high affinity and binding interaction by establishing an Ab-BSA©CuNC/MoS2 platform. The luminescence of Ab-BSA©CuNCs was restored due to the antigen-antibody interaction. With a detection limit of 9.4 pg/mL, a linear relationship between the luminescence intensity concentrations of cTnT was observed in the 0.161-1.57 ng/mL ranges. Additionally, the efficacy of the developed technique to measure cTnT in blood serum samples was evaluated, and it exhibited a good recovery percentage.
- 27 December 2024
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 8 (1) , 835-843
Bovine Serum Albumin-Capped Fluorescent Copper Nanocluster Incorporated with 2D-Molybdenum Disulfide Nanosheets as a FRET-Based Immune Probe for the “Turn-On” Detection of cTnT
Cardiovascular disease is the primary cause of mortality worldwide, as stated by the World Health Organization. We utilized the red fluorescence emitted by copper nanoclusters (CuNCs) to detect cardiac Troponin T (cTnT). We designed a fluorescent probe to detect cTnT using an on-off-on technique. The cTnT antibody was coupled on the surface of a bovine serum albumin-capped CuNC (Ab-BSA©CuNC) MoS2 nanosheet, efficiently quenching the luminescence of Ab-BSA©CuNCs due to their high affinity and binding interaction by establishing an Ab-BSA©CuNC/MoS2 platform. The luminescence of Ab-BSA©CuNCs was restored due to the antigen-antibody interaction. With a detection limit of 9.4 pg/mL, a linear relationship between the luminescence intensity concentrations of cTnT was observed in the 0.161-1.57 ng/mL ranges. Additionally, the efficacy of the developed technique to measure cTnT in blood serum samples was evaluated, and it exhibited a good recovery percentage.
- 27 December 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (5) , 1125-1136
Tungsten disulphide nanosheet modulated fluorescent gold nanocluster immunoprobe for the detection of tau peptide: Alzheimer's disease biomarker
An immunoprobe is designed with red fluorescent AuNCs and WS2 NS for tau peptide detection, an Alzheimer's disease biomarker by strong antigen–antibody interaction, with high sensitivity in human serum samples.
- 27 December 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (5) , 1125-1136
Tungsten disulphide nanosheet modulated fluorescent gold nanocluster immunoprobe for the detection of tau peptide: Alzheimer's disease biomarker
An immunoprobe is designed with red fluorescent AuNCs and WS2 NS for tau peptide detection, an Alzheimer's disease biomarker by strong antigen–antibody interaction, with high sensitivity in human serum samples.
- 10 December 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 329, 125572
Red emitting fluorescence sensor based on Eu-tungstate complex for the detection of bilirubin in biological fluid
- 10 December 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 329, 125572
Red emitting fluorescence sensor based on Eu-tungstate complex for the detection of bilirubin in biological fluid
- 4 December 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (2) , 329-341
Quantum dot-to-dye-based fluorescent ratiometric immunoassay for GFAP: a biomarker for ischaemic stroke and glioblastoma multiforme
Ischaemic stroke and glioma, as leading causes of mortality and long-term disability, pose critical challenges to healthcare systems, necessitating innovative approaches to enable early and cost-effective diagnosis for timely intervention. Glial fibrillary acidic protein (GFAP), an astrocyte-produced protein, is highly responsive to both ischaemic stroke and glioblastoma multiforme, with its levels correlating to the extent of brain damage. In this study, we present the development of an immunoassay probe for the ratiometric fluorescent detection of glial fibrillary acidic protein (GFAP), employing a monoclonal GFAP antibody-conjugated silicon quantum dots (Ab@SiQDs) and rhodamine B dye (RhB)-based immunoprobe. The developed probe exhibited a fluorescence emission shift from 580 nm to 530 nm in response to GFAP, demonstrating a linear detection range from 31.15 pg mL−1 to 243 pg mL−1, with a limit of detection of 0.7 pg mL−1. Additionally, the immunoprobe showed high selectivity for GFAP, effectively discriminating it from other potential interfering biomolecules and ions. The probe was also capable of detecting GFAP in spiked serum samples, achieving a recovery rate ranging from 83% to 111%. Notably, a cost-effective paper strip assay was developed, offering significant potential for the visual detection of GFAP under ultraviolet illumination.
- 4 December 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (2) , 329-341
Quantum dot-to-dye-based fluorescent ratiometric immunoassay for GFAP: a biomarker for ischaemic stroke and glioblastoma multiforme
Ischaemic stroke and glioma, as leading causes of mortality and long-term disability, pose critical challenges to healthcare systems, necessitating innovative approaches to enable early and cost-effective diagnosis for timely intervention. Glial fibrillary acidic protein (GFAP), an astrocyte-produced protein, is highly responsive to both ischaemic stroke and glioblastoma multiforme, with its levels correlating to the extent of brain damage. In this study, we present the development of an immunoassay probe for the ratiometric fluorescent detection of glial fibrillary acidic protein (GFAP), employing a monoclonal GFAP antibody-conjugated silicon quantum dots (Ab@SiQDs) and rhodamine B dye (RhB)-based immunoprobe. The developed probe exhibited a fluorescence emission shift from 580 nm to 530 nm in response to GFAP, demonstrating a linear detection range from 31.15 pg mL−1 to 243 pg mL−1, with a limit of detection of 0.7 pg mL−1. Additionally, the immunoprobe showed high selectivity for GFAP, effectively discriminating it from other potential interfering biomolecules and ions. The probe was also capable of detecting GFAP in spiked serum samples, achieving a recovery rate ranging from 83% to 111%. Notably, a cost-effective paper strip assay was developed, offering significant potential for the visual detection of GFAP under ultraviolet illumination.