Meng Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Meng Lu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Xiao Liu
Hunan University
3 shared publications - Chenxi Xia
College of Electrical and Information Engineering, Hunan University, Changsha, China
1 shared publication Dongpei Lu
NR Electric Company Ltd
1 shared publication- Lin Zhang
Hunan University
1 shared publication - Pingting Lin
Hunan University
1 shared publication - Shoudao Huang
Hunan University
1 shared publication
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 8201205
Investigation of the Dynamic Characteristics of the Multi-Port Dual-Flux-Modulation Magnetic-Geared Machine With Damper Cage
This paper presents a Multi-port Dual Flux Modulation Magnetic Geared Machine (MDFM-MGM) incorporating damper cage in the outer rotor for electric mining trucks (EMTs). A theoretical comparison between different topology of damper bars in the outer rotor is studied. The numerical models of the MDFM-MGM are established by 2-D finite-element method (FEM). The spatial-temporal spectrum of the air-gap flux density is analyzed, and characterized the influence of damper cage on the improvement of dynamic characteristics including current profile, torque, and speed under different conditions such as start-up and the abrupt change of load. The experimental platform of the proposed machine is established. The stability of the MDFM-MGM with damper cage under changes of operating conditions was verified through experiments. The topology equipped with the damper cage achieves a 43% reduction in transient response time compared to the configuration without the damper cage. Moreover, the stall torque which may cause loss of synchronism for the MDFM-MGM is also tested. Owing to the parallel energy convergence function of the MDFM-MGM, the locked-rotor torque of the outer rotor reaches 272 Nm, representing a 36.4% increase compared to that achieved under single-port driving.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 8201205
Investigation of the Dynamic Characteristics of the Multi-Port Dual-Flux-Modulation Magnetic-Geared Machine With Damper Cage
This paper presents a Multi-port Dual Flux Modulation Magnetic Geared Machine (MDFM-MGM) incorporating damper cage in the outer rotor for electric mining trucks (EMTs). A theoretical comparison between different topology of damper bars in the outer rotor is studied. The numerical models of the MDFM-MGM are established by 2-D finite-element method (FEM). The spatial-temporal spectrum of the air-gap flux density is analyzed, and characterized the influence of damper cage on the improvement of dynamic characteristics including current profile, torque, and speed under different conditions such as start-up and the abrupt change of load. The experimental platform of the proposed machine is established. The stability of the MDFM-MGM with damper cage under changes of operating conditions was verified through experiments. The topology equipped with the damper cage achieves a 43% reduction in transient response time compared to the configuration without the damper cage. Moreover, the stall torque which may cause loss of synchronism for the MDFM-MGM is also tested. Owing to the parallel energy convergence function of the MDFM-MGM, the locked-rotor torque of the outer rotor reaches 272 Nm, representing a 36.4% increase compared to that achieved under single-port driving.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 8201306
Optimal Design of a High-Efficiency Permanent Magnet-Assisted Synchronous Reluctance Motor Considering Anti-Demagnetization Performance
To address the issues of low efficiency and susceptibility to demagnetization in ferrite permanent magnets for Permanent Magnet Assisted Synchronous Reluctance Motors(PMaSynRMs), an optimal design method that comprehensively considers anti-demagnetization performance is proposed. Based on anti-demagnetization analysis, design variables are determined under the constraint of a 5% maximum fault-current demagnetization rate. Moreover, a self-iterative Expected Improvement (EI) criterion-based Kriging model is proposed, which automatically concludes the adding points process and improves prediction accuracy of the surrogate model. Subsequently, multi-objective optimization focused on improving efficiency and torque is performed using a multi-objective particle swarm optimization (MOPSO) algorithm. The optimized motor achieves an efficiency of 94.9%, representing a 2.9% improvement over the initial design, while the maximum demagnetization rate of the ferrite under fault conditions is controlled within 4.91%. Experiments confirm an efficiency of 94.8% under rated operating conditions, a wide high-efficiency operating region, and satisfactory anti-demagnetization performance.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 8201306
Optimal Design of a High-Efficiency Permanent Magnet-Assisted Synchronous Reluctance Motor Considering Anti-Demagnetization Performance
To address the issues of low efficiency and susceptibility to demagnetization in ferrite permanent magnets for Permanent Magnet Assisted Synchronous Reluctance Motors(PMaSynRMs), an optimal design method that comprehensively considers anti-demagnetization performance is proposed. Based on anti-demagnetization analysis, design variables are determined under the constraint of a 5% maximum fault-current demagnetization rate. Moreover, a self-iterative Expected Improvement (EI) criterion-based Kriging model is proposed, which automatically concludes the adding points process and improves prediction accuracy of the surrogate model. Subsequently, multi-objective optimization focused on improving efficiency and torque is performed using a multi-objective particle swarm optimization (MOPSO) algorithm. The optimized motor achieves an efficiency of 94.9%, representing a 2.9% improvement over the initial design, while the maximum demagnetization rate of the ferrite under fault conditions is controlled within 4.91%. Experiments confirm an efficiency of 94.8% under rated operating conditions, a wide high-efficiency operating region, and satisfactory anti-demagnetization performance.
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1-10
Sensorless Control of PMSM Based on Improved Finite Position Set Phase-Locked Loop with Low Computational Load
Conventional fixed-gain PI phase-locked loops (PLLs) used in sensorless drive control of permanent magnet synchronous motors (PMSMs) often suffer from slow dynamic response and poor parameter robustness. An improved finite position set PLL (FPS-PLL) which may achieve high dynamic response with low computational burden is proposed in this paper. By calculating the initial iteration value through the Taylor expansion of the arctangent function, the range of initial iteration errors is narrowed, thereby reducing the number of iterations required. The rotor position is then efficiently estimated by Newton iteration. Position estimation accuracy achieves 4.96e-8 rad after just only one iteration. The proposed method provides superior dynamic performance and low computational load without parameter tuning of PLL. The performance of the proposed FPS-PLL have been experimentally investigated and compared with that of the Binary-FPS-PLL and classical PI-PLL using a 1.5 kW interior PMSM (IPMSM). The results of experiment demonstrate the effectiveness of the proposed FPS-PLL under various operating conditions.
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1-10
Sensorless Control of PMSM Based on Improved Finite Position Set Phase-Locked Loop with Low Computational Load
Conventional fixed-gain PI phase-locked loops (PLLs) used in sensorless drive control of permanent magnet synchronous motors (PMSMs) often suffer from slow dynamic response and poor parameter robustness. An improved finite position set PLL (FPS-PLL) which may achieve high dynamic response with low computational burden is proposed in this paper. By calculating the initial iteration value through the Taylor expansion of the arctangent function, the range of initial iteration errors is narrowed, thereby reducing the number of iterations required. The rotor position is then efficiently estimated by Newton iteration. Position estimation accuracy achieves 4.96e-8 rad after just only one iteration. The proposed method provides superior dynamic performance and low computational load without parameter tuning of PLL. The performance of the proposed FPS-PLL have been experimentally investigated and compared with that of the Binary-FPS-PLL and classical PI-PLL using a 1.5 kW interior PMSM (IPMSM). The results of experiment demonstrate the effectiveness of the proposed FPS-PLL under various operating conditions.