MLMinghui Liang

Minghui Liang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Minghui Liang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Machine Learning and Deep Learning for the Diagnosis of Cervical Degenerative Diseases: Systematic Review and Meta-Analysis

    by Hongwei Duan, Ruiyuan Chen, Minghui Liang, Liqian Wang, Tianyi Wang, Aobo Wang, Ziqian Ma, Yu Xi, Shuo Yuan, Ning Fan, et al.

    Background: Cervical degenerative diseases are a global public health issue, and their incidence is rising worldwide. Although an increasing number of studies on traditional machine learning (TML) and deep learning (DL) have been conducted in the detection and segmentation of cervical degenerative diseases and have reported promising task-specific results, the performance of these models has not yet been systematically analyzed. Objective: This systematic review and meta-analysis aimed to summarize and evaluate existing evidence on TML and DL approaches for diagnosing cervical degenerative diseases, thereby comprehensively guiding future research and clinical applications. Methods: This systematic review was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. A comprehensive literature search was conducted on PubMed, Embase, the Cochrane Library, Web of Science, Scopus, and the Institute of Electrical and Electronics Engineers (IEEE Xplore) from January 2000 to June 2026, supplemented by backward and forward citation searching in Scopus. Studies evaluating TML and DL algorithms for diagnosing cervical degenerative diseases using medical imaging were included. Methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool and the Quality Assessment of Diagnostic Accuracy Studies AI (QUADAS-AI) tool. For the primary diagnostic accuracy meta-analysis, data were synthesized using a bivariate mixed-effects logistic regression model. Sensitivity and specificity were summarized separately using random-effects meta-analysis with the Knapp-Hartung adjustment, and 95% prediction intervals (PIs) were reported. Certainty of evidence was assessed using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) approach. Results: This systematic review included 30 studies, of which 21 involved a total of 25,301 patients included in the meta-analysis. The pooled sensitivity and specificity were 0.92 (95% CI 0.89‐0.96; 95% PI 0.80‐1.00) and 0.88 (95% CI 0.84‐0.91; 95% PI 0.72‐1.00), respectively. The positive likelihood ratio (LR) was 8.36 (95% CI 6.14‐11.36), and the negative LR was 0.07 (95% CI 0.04‐0.11). The area under the summary receiver operating characteristic (SROC) curve was 0.96 (95% CI 0.94‐0.97). Leave-one-out analyses did not materially alter the pooled estimates. High risk of bias was identified in 4 studies using QUADAS-2 and in 17 using QUADAS-AI. The overall certainty of evidence was rated as low according to the GRADE approach. Conclusions: TML and DL models demonstrated satisfactory diagnostic performance for cervical degenerative diseases, although external validation was limited. Unlike previously published reviews in this field, this study provides pooled estimates of the diagnostic performance of TML and DL for cervical degenerative diseases and indicates that, given between-study heterogeneity and low certainty of evidence, AI should currently be used as clinical decision support rather than an independent replacement for physicians.

  • Open Access

    A Deep Learning–Based Multimodal Fusion Model for Predicting Bone Cement Leakage in Percutaneous Kyphoplasty: Development and Validation

    by Tianyi Wang, Yu Xi, Ruiyuan Chen, Xingyu Liu, Dong Liu, Minghui Liang, Tianlang Xie, Baodong Wang, Aobo Wang, Ning Fan, et al.

    Background: There is a lack of intelligent methodologies that effectively integrate multimodal information to predict bone cement leakage (BCL) during percutaneous kyphoplasty (PKP). This study aimed to develop and validate a deep learning (DL)–based multimodal fusion model that incorporates preoperative CT, MRI, and clinical variables to predict BCL subtypes during PKP. Methods: This study included a retrospective internal dataset for model training and validation, a prospective internal dataset, and an external dataset for independent testing. The fusion model incorporated preoperative spinal CT, MRI, and structured clinical baseline data within a two‐stage framework. The first stage consisted of target vertebra localization based on vertebral segmentation. The second stage comprised a classification module implemented using a multibranch 3D ResNet‐50 network. Performance was compared with image‐only models, single‐modality models, and spine surgeons using the area under the receiver operating characteristic curve (AUC), the area under the precision–recall curve, and other metrics. Results: The multimodal DL model achieved AUC values ranging from 0.795 to 0.861 in the internal test set and from 0.767 to 0.848 in the external test set for predicting BCL subtypes. Type III leakage demonstrated the highest predictive performance (internal AUC, 0.861; external AUC, 0.848). Overall, the fusion model achieved the highest AUC values and showed superior accuracy and agreement compared with spine surgeons, particularly for Type I ( κ : internal, 0.439 vs. 0.030–0.075; external, 0.298 vs. 0.019–0.066) and Type IV leakage ( κ : internal, 0.459 vs. 0.133–0.186; external, 0.545 vs. 0.002–0.095). Conclusion: A two‐stage multimodal fusion DL framework enables accurate, reliable, and promisingly generalizable prediction of BCL subtypes in PKP, outperforming spine surgeons and supporting individualized preoperative decision‐making.

  • Open Access

    Performance of DeepSeek-R1 and ChatGPT-5 in the Generation of North American Spine Society Clinical Guidelines for Adult Vertebral Compression Fractures: Comparative Study

    by Ruiyuan Chen, Yue Pan, Minghui Liang, Aobo Wang, Ziqian Ma, Yu Xi, Ning Fan, Shuo Yuan, Peng Du, Tianyi Wang, et al.

    Background: Vertebral compression fractures (VCFs) impose a substantial clinical and health care burden, and their management relies on timely access to evidence-based guidelines. Large language models (LLMs) may help clinicians rapidly obtain guideline-related information, but their performance on VCF guidelines remains unclear. Objective: This study aimed to evaluate the performance of LLMs, including DeepSeek-R1 and ChatGPT-5, in generating responses consistent with VCF clinical guidelines. Methods: Using the 2024 North American Spine Society VCF clinical guidelines as the reference standard, 34 open-ended and 87 closed-ended questions were submitted to DeepSeek-R1 and ChatGPT-5. Four senior spine surgeons independently rated responses to both closed-ended and open-ended questions using a 5-point Likert scale for accuracy, consistency, self-awareness, and fabrication/falsification. For open-ended questions, comprehensiveness, clarity, and trust and confidence were additionally assessed. Subgroup analyses were performed by question type, recommendation grade, and VCF subtype, with direct comparisons between models. Results: A total of 726 responses were generated for 121 questions. For closed-ended questions, ChatGPT-5 and DeepSeek-R1 showed comparable performance in accuracy ( P =.11), self-awareness ( P =.10), and fabrication/falsification ( P =.10). DeepSeek-R1 demonstrated better consistency than ChatGPT-5 for both closed-ended and open-ended questions ( P <.001 and P =.001, respectively). For open-ended questions, the models differed significantly in comprehensiveness ( P =.03) and trust and confidence ( P =.02), but not in accuracy ( P =.42), self-awareness ( P =.22), fabrication/falsification ( P =.64), or clarity ( P =.48). Closed-ended questions generally outperformed open-ended questions. Responses to grade A-C recommendations outperformed grade I recommendations in accuracy, consistency, and fabrication/falsification (all P ≤.001) but scored lower in self-awareness ( P <.001). No significant differences were observed across VCF subtypes. Conclusions: Under a standardized clinician-oriented prompting condition, ChatGPT-5 and DeepSeek-R1 showed generally high but variable scores across evaluation dimensions, with important deficiencies remaining, particularly in interventional and surgical treatment recommendations and in questions linked to recommendation grade I. Because these findings were obtained in a controlled prompting setting, caution is warranted when extrapolating them to other query styles, clinical scenarios, or LLMs.

  • Open Access

    Performance of DeepSeek V3.2 and ChatGPT 5.1 in Musculoskeletal Triage and Differential Diagnosis of Outpatients With Low Back Pain: Multidimensional Comparative Study

    by Ziqian Ma, Ruiyuan Chen, Aobo Wang, Yu Xi, Minghui Liang, Shuo Yuan, Ning Fan, Jianwei Zang, Tianyi Wang, Lei Zang

    Background: Outpatients presenting with low back pain (LBP) often require efficient preconsultation triage and early differential diagnostic support. Large language models may assist these text-based tasks, but their performance under different clinical information conditions remains unclear. Objective: This study aimed to compare the performance of ChatGPT (5.1; OpenAI) and DeepSeek (V3.2; DeepSeek AI) in musculoskeletal disorders (MSDs) triage and the differential diagnosis of outpatients with LBP using real-world outpatient records under 2 simulated information conditions. Methods: This retrospective comparative study was conducted at a tertiary academic teaching hospital in Beijing. A total of 160 cases were included using a balanced design across 8 diagnostic categories (20 per category); 6 MSDs and 2 non-MSDs. Evaluation was performed in 2 phases: Phase 1 (chief complaint) and Phase 2 (structured questionnaire with 7 domains or 33 items), both executed in a zero-shot setting using standardized prompts. Outcomes included (1) triage accuracy, (2) preliminary diagnosis accuracy, and (3) differential diagnosis agreement. In Phase 2, 3 senior orthopedic evaluators additionally rated model rationales across 5 domains using a 5-point Likert scale. Results: For triage accuracy across all 160 cases, DeepSeek V3.2 improved from 84.4% to 90.6% (risk difference [RD] 6.2%, 95% CI –0.7% to 13.3%), and ChatGPT 5.1 improved from 75.6% to 93.1% (RD 17.5%, 95% CI 10.2%-24.9%). For preliminary diagnosis accuracy across the 120 musculoskeletal cases, DeepSeek V3.2 improved from 48.3% to 76.7% (RD 28.3%, 95% CI 16.8%-38.8%), whereas ChatGPT 5.1 improved from 35.0% to 87.5% (RD 52.5%, 95% CI 42.8%-60.6%). The mean number of correct differential diagnoses increased from 1.27 (SD 0.71) to 2.02 (SD 0.74) for DeepSeek V3.2 and from 1.34 (SD 0.70) to 2.03 (SD 0.77) for ChatGPT 5.1. In Phase 2, rationale ratings were generally good for both models, with ChatGPT 5.1 scoring higher in understanding and reasoning. Recognition of multiple myeloma (MM) remained limited, improving only from 45% to 55% (DeepSeek V3.2) and 55% to 60% (ChatGPT 5.1). Structured input reduced safety-risk errors in both models, but residual errors remained, especially for MM and metastatic spinal tumor. Conclusions: Both ChatGPT 5.1 and DeepSeek V3.2 demonstrated potential in text-based triage and differential diagnosis of MSDs for LBP, with structured clinical information generally improving performance, particularly for preliminary diagnosis accuracy and differential diagnosis agreement. However, their suboptimal sensitivity for red-flag conditions such as MM highlights significant safety concerns, indicating that they should not be used as stand-alone triage tools without clinician oversight. ChatGPT 5.1 showed stronger reasoning with structured inputs based on rationale ratings, whereas DeepSeek V3.2 showed better performance under chief-complaint-only input, with significantly higher Phase 1 preliminary diagnostic accuracy and numerically higher Phase 1 triage accuracy. These findings underscore the need for further model refinement, rigorous prospective validation, and integration with clinician oversight before clinical implementation.


  • Open Access

    Deep Learning-Assisted Lumbar Degeneration Evaluation Using Plain Radiographs: Development and Validation of a Novel Dual-Mechanism Architecture

    by Ziqian Ma, Aobo Wang, Xingyu Liu, Ruiyuan Chen, Tianyi Wang, Yu Xi, Minghui Liang, Ning Fan, Shuo Yuan, Peng Du, et al.

    Objective: To develop and externally validate a dual-mechanism deep learning (DL) model that integrates vertebral segmentation and lesion detection for automated evaluation of lumbar degeneration and structured report generation on plain radiographs.Methods: In this retrospective study, 5,964 patients who underwent standing anteroposterior and lateral lumbar radiographs at a single institution and 600 patients from a public dataset (BUU-Spine) were included. Vertebral corners from T11–L5 (and S1 on lateral views) and 7 degenerative findings (scoliosis, straightened/preserved lordosis, spondylolisthesis, disc space narrowing, osteophytes, vertebral compression, and abdominal aortic calcification) were annotated by 3 spine surgeons. Two independently trained, parallel networks were developed, including a ResNet-based segmentation network and a YOLOv8-based detection network. A rule-based integration strategy reconciled both outputs and generated structured diagnostic reports. Segmentation accuracy, quantitative measurement agreement, diagnostic performance, and clinical acceptability of reports were evaluated.Results: Intra- and interobserver landmark distances within 3 mm reached 96% and >95%, respectively. On the internal test set, the percentage of correct keypoints within 3 mm was 95.7%–98.6%, with intraclass correlation coefficients of 0.84–0.89 and Pearson correlation coefficient (r) of 0.90–0.94 for key radiographic parameters. The segmentation- and detection-based models achieved precision of 92.2%–96.9% and 91.7%–95.5%, and recall of 91.6%–94.8% and 93.3%–95.2%, respectively. Under the dual-positive condition, the integrated model yielded the highest precision (93.8%–97.3%), whereas the any-positive condition achieved the highest recall (94.1%–97.6%). Of 596 automatically generated structured reports, 557 (93.4%) were deemed clinically acceptable.Conclusion: The proposed dual-mechanism DL framework enables accurate, multilesion assessment of lumbar degeneration and generation of clinically acceptable structured reports from plain radiographs, supporting workflow optimization in lumbar spine imaging.