Peterson L. Squair
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peterson L. Squair has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Bruno Melo Mendes
Centro de Desenvolvimento da Tecnologia Nuclear – CDTN/CNEN, Belo Horizonte, Brazil
1 shared publication - Carolina S. Lamounier
Nuclear Technology Development Center (CDTN), National Nuclear Energy Commission (CNEN), Belo Horizonte, Brazil
1 shared publication - Isabela N. S. Ferreira
Nuclear Technology Development Center (CDTN), National Nuclear Energy Commission (CNEN), Belo Horizonte, Brazil
1 shared publication - Júlia B. Severo
Nuclear Technology Development Center (CDTN), Belo Horizonte, 31270-901, Brazil
1 shared publication - Laura Cardoso Takahashi
Nuclear Technology Development Center (CDTN), National Nuclear Energy Commission (CNEN), Belo Horizonte, Brazil
1 shared publication - M. S. Nogueira
Centro de Desenvolvimento da Tecnologia Nuclear – CDTN/CNEN, Belo Horizonte, Brazil
1 shared publication
Latest Publications
- Open Access
- 4 August 2026
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 335 (8) , 5767-5780
Radiometric investigation of indoor environments: assessment of radon and gamma radiation exposure in residences of a tropical metropolitan city in Brazil
This study evaluated indoor exposure to radon-222 and gamma radiation in Belo Horizonte, Brazil, aiming to characterize natural radiation levels in residential environments. Radon concentrations showed spatial variability and a pronounced seasonal variation, highlighting the influence of climatic and ventilation conditions on radon accumulation, with some residences exceeding recommended reference levels. The integrated assessment of radon and external gamma radiation indicated annual exposure values comparable to global natural radiation levels. The findings highlight the influence of local environmental conditions and the importance of systematic monitoring to support radiological protection strategies in Brazil.
- 4 August 2026
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 335 (8) , 5767-5780
Open AccessRadiometric investigation of indoor environments: assessment of radon and gamma radiation exposure in residences of a tropical metropolitan city in Brazil
This study evaluated indoor exposure to radon-222 and gamma radiation in Belo Horizonte, Brazil, aiming to characterize natural radiation levels in residential environments. Radon concentrations showed spatial variability and a pronounced seasonal variation, highlighting the influence of climatic and ventilation conditions on radon accumulation, with some residences exceeding recommended reference levels. The integrated assessment of radon and external gamma radiation indicated annual exposure values comparable to global natural radiation levels. The findings highlight the influence of local environmental conditions and the importance of systematic monitoring to support radiological protection strategies in Brazil.
- Open Access
- 6 April 2026
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 235 (4) , 1413-1419
Measurement of spectra in mammography using different phantoms
Evaluation of the performance of mammographic equipment requires the imaging and interpretation of test objects or phantoms and risk assessment. This study evaluated, using a spectrometry technique, the linear attenuation coefficients determined from transmitted intensity for commercially available tissue-equivalent phantoms for mammography, namely the Computerized Imaging Reference Systems (CIRS) phantom with different glandularity–adipose contents and PMMA. The measurements were performed using X-ray beams produced by Mo/Mo, Mo/Rh, and W/Rh target/filter combinations. The results are presented for the characteristic X-ray photopeaks (Mo Kα 1 at 17.48 keV and Mo Kα 2 at 19.61 keV). Spectrometry measurements were carried out using an Amptek XR-100T Cadmium Telluride (CdTe) detector, and the spectra were corrected using MCNP6 simulations. This work demonstrates the adequacy of the results obtained for Mo Kα 1 at 17.48 keV when compared with publications that applied different methods of analysis. In addition, it presents the evaluation of the attenuation coefficient for Mo Kα 2 at 19.61 keV for the CIRS phantom and its comparison with PMMA results.
- 6 April 2026
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 235 (4) , 1413-1419
Open AccessMeasurement of spectra in mammography using different phantoms
Evaluation of the performance of mammographic equipment requires the imaging and interpretation of test objects or phantoms and risk assessment. This study evaluated, using a spectrometry technique, the linear attenuation coefficients determined from transmitted intensity for commercially available tissue-equivalent phantoms for mammography, namely the Computerized Imaging Reference Systems (CIRS) phantom with different glandularity–adipose contents and PMMA. The measurements were performed using X-ray beams produced by Mo/Mo, Mo/Rh, and W/Rh target/filter combinations. The results are presented for the characteristic X-ray photopeaks (Mo Kα 1 at 17.48 keV and Mo Kα 2 at 19.61 keV). Spectrometry measurements were carried out using an Amptek XR-100T Cadmium Telluride (CdTe) detector, and the spectra were corrected using MCNP6 simulations. This work demonstrates the adequacy of the results obtained for Mo Kα 1 at 17.48 keV when compared with publications that applied different methods of analysis. In addition, it presents the evaluation of the attenuation coefficient for Mo Kα 2 at 19.61 keV for the CIRS phantom and its comparison with PMMA results.