Florian Gross
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Florian Gross has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Raphael Seiler
Department of Congenital Heart Disease—Pediatric Cardiology, Deutsches Herzzentrum der Charité, Augustenburger Platz 1, 13353 Berlin, Germany
2 shared publications - Alexander Ivanovich Bobenko
Institut für Mathematik, Technische Universität Berlin, Berlin, Germany
1 shared publication Alexandra Hinke
Charité - Universitätsmedizin Berlin, corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin , Charitéplatz 1, Berlin 10117
1 shared publication- Alexandra Hinke
Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
1 shared publication Felix Berger
Department of Congenital Heart Disease—Pediatric Cardiology, Deutsches Herzzentrum der Charité , Augustenburger Platz 1, Berlin 13353
1 shared publication- Felix Berger
Department of Congenital Heart Disease—Pediatric Cardiology, Deutsches Herzzentrum der Charité, Augustenburger Platz 1, 13353 Berlin, Germany
1 shared publication
Latest Publications
- Open Access
- 6 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (9) , 3540
First Clinical Results of Novel Haemodynamic Simulation Software for Patient-Specific Qp:Qs Quantification in Patients with Atrial Septal Defect Using Routine 2D Echocardiographic Data
Background/Objectives: Accurate quantification of left-to-right shunt volume is central to clinical decision-making in patients with atrial septal defect (ASD). Conventional echocardiographic Qp:Qs estimation is widely used but limited by operator dependency, Doppler alignment sensitivity, and the quadratic amplification of diameter measurement errors in flow calculations. These factors contribute to clinically relevant variability, particularly in paediatric populations with small vessel dimensions. Simulation-based haemodynamic modelling offers an alternative approach by integrating structural and functional cardiac parameters within a patient-specific computational framework, independent of direct Doppler flow measurements. Methods: This retrospective single-centre study evaluated agreement between conventional Doppler-derived and software-based Qp:Qs quantification using a three-dimensional haemodynamic simulation model. Transthoracic echocardiographic datasets from patients with isolated secundum ASD undergoing defect closure between 2018 and 2024 were analysed. Conventional Qp:Qs was calculated using pulmonary and aortic valve diameter and velocity–time integral measurements, while software-derived Qp:Qs was computed from patient-specific haemodynamic modelling based on cardiac chamber geometry and physiological parameters. Mean values were compared using Student’s t-test. Agreement was assessed using Bland–Altman analysis. A predefined ± 20% deviation threshold was considered clinically acceptable according to the study protocol. Results: A total of 98 echocardiographic examinations from 94 patients were included. Mean Qp:Qs was 1.83 ± 0.45 by echocardiography and 1.73 ± 0.47 by simulation modelling, with no statistically significant difference between methods (p Using the predefined ± 20% deviation criterion, 53.1% of examinations fell within the acceptable range. Larger ASD diameter was associated with increased inter-method deviation. Conclusions: This study provides an initial feasibility evaluation of a novel haemodynamic simulation approach enabling patient-specific three-dimensional modelling of cardiac structures and shunt physiology based on routine echocardiographic data. Simulation-derived Qp:Qs estimates demonstrated no systematic difference in comparison with conventional Doppler-based quantification and were feasible within routine clinical workflows. Ongoing prospective validation against invasive haemodynamic reference standards will further define analytical accuracy and potential clinical applicability.
- 6 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (9) , 3540
Open AccessFirst Clinical Results of Novel Haemodynamic Simulation Software for Patient-Specific Qp:Qs Quantification in Patients with Atrial Septal Defect Using Routine 2D Echocardiographic Data
Background/Objectives: Accurate quantification of left-to-right shunt volume is central to clinical decision-making in patients with atrial septal defect (ASD). Conventional echocardiographic Qp:Qs estimation is widely used but limited by operator dependency, Doppler alignment sensitivity, and the quadratic amplification of diameter measurement errors in flow calculations. These factors contribute to clinically relevant variability, particularly in paediatric populations with small vessel dimensions. Simulation-based haemodynamic modelling offers an alternative approach by integrating structural and functional cardiac parameters within a patient-specific computational framework, independent of direct Doppler flow measurements. Methods: This retrospective single-centre study evaluated agreement between conventional Doppler-derived and software-based Qp:Qs quantification using a three-dimensional haemodynamic simulation model. Transthoracic echocardiographic datasets from patients with isolated secundum ASD undergoing defect closure between 2018 and 2024 were analysed. Conventional Qp:Qs was calculated using pulmonary and aortic valve diameter and velocity–time integral measurements, while software-derived Qp:Qs was computed from patient-specific haemodynamic modelling based on cardiac chamber geometry and physiological parameters. Mean values were compared using Student’s t-test. Agreement was assessed using Bland–Altman analysis. A predefined ± 20% deviation threshold was considered clinically acceptable according to the study protocol. Results: A total of 98 echocardiographic examinations from 94 patients were included. Mean Qp:Qs was 1.83 ± 0.45 by echocardiography and 1.73 ± 0.47 by simulation modelling, with no statistically significant difference between methods (p Using the predefined ± 20% deviation criterion, 53.1% of examinations fell within the acceptable range. Larger ASD diameter was associated with increased inter-method deviation. Conclusions: This study provides an initial feasibility evaluation of a novel haemodynamic simulation approach enabling patient-specific three-dimensional modelling of cardiac structures and shunt physiology based on routine echocardiographic data. Simulation-derived Qp:Qs estimates demonstrated no systematic difference in comparison with conventional Doppler-based quantification and were feasible within routine clinical workflows. Ongoing prospective validation against invasive haemodynamic reference standards will further define analytical accuracy and potential clinical applicability.
- Open Access
- 18 December 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 4 (1)
From simple measurement to a complex form: right ventricular volumetry using 2D-echocardiography—a retrospective cohort study
Aims: Assessment of right ventricular volume is crucial for monitoring patients with congenital heart defects. However, due to the right ventricle’s complex geometry, 2D echocardiography is challenging and MRI is commonly used to evaluate right ventricular volume. However, MRI has several limitations: it lacks bedside imaging, is time-consuming, and often requires sedation in patients with congenital heart defects. Therefore, we aimed to develop a reliable and simple method for calculating right ventricular volume using 2D echocardiography. Methods and results: Standard apical 4-chamber and parasternal short-axis views were obtained using 2D echocardiography in 40 congenital heart defects patients. Right ventricular volumes were calculated using an ellipsoidal shell model, a truncated cone model and a novel approach based on a cone model: VRV=23(ASAX+18πdTV2)A4CHdTV. The results were compared with right ventricular volumes obtained via MRI. The proposed cone-based model demonstrated excellent correlation to right ventricular volumes obtained by MRI (systolic: ICC = 0.98 (95% CI 0.95–0.99)/diastolic: ICC = 0.96 (95% CI 0.92–0.98)). The mean difference from MRI-measured systolic volume was 0.1 mL (SD ± 13.3) and from diastolic volume 5.2 mL (SD ± 28.2). Based on the root mean square error (RMSE) our cone model (RMSE 13.2 mL/28.4 mL systolic/diastolic) demonstrates significantly better predictive accuracy than the traditional ellipsoidal shell model (RMSE 20.8 mL/52.6 mL systolic/diastolic) and the truncated cone model (RMSE 25.1 mL/42.3 mL systolic/diastolic). Conclusion: Our method shows excellent alignment with MRI data. It offers an accurate and rapid method for bedside assessment of right ventricular volume with 2D echocardiography, enhancing prompt and precise clinical decision-making.
- 18 December 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 4 (1)
Open AccessFrom simple measurement to a complex form: right ventricular volumetry using 2D-echocardiography—a retrospective cohort study
Aims: Assessment of right ventricular volume is crucial for monitoring patients with congenital heart defects. However, due to the right ventricle’s complex geometry, 2D echocardiography is challenging and MRI is commonly used to evaluate right ventricular volume. However, MRI has several limitations: it lacks bedside imaging, is time-consuming, and often requires sedation in patients with congenital heart defects. Therefore, we aimed to develop a reliable and simple method for calculating right ventricular volume using 2D echocardiography. Methods and results: Standard apical 4-chamber and parasternal short-axis views were obtained using 2D echocardiography in 40 congenital heart defects patients. Right ventricular volumes were calculated using an ellipsoidal shell model, a truncated cone model and a novel approach based on a cone model: VRV=23(ASAX+18πdTV2)A4CHdTV. The results were compared with right ventricular volumes obtained via MRI. The proposed cone-based model demonstrated excellent correlation to right ventricular volumes obtained by MRI (systolic: ICC = 0.98 (95% CI 0.95–0.99)/diastolic: ICC = 0.96 (95% CI 0.92–0.98)). The mean difference from MRI-measured systolic volume was 0.1 mL (SD ± 13.3) and from diastolic volume 5.2 mL (SD ± 28.2). Based on the root mean square error (RMSE) our cone model (RMSE 13.2 mL/28.4 mL systolic/diastolic) demonstrates significantly better predictive accuracy than the traditional ellipsoidal shell model (RMSE 20.8 mL/52.6 mL systolic/diastolic) and the truncated cone model (RMSE 25.1 mL/42.3 mL systolic/diastolic). Conclusion: Our method shows excellent alignment with MRI data. It offers an accurate and rapid method for bedside assessment of right ventricular volume with 2D echocardiography, enhancing prompt and precise clinical decision-making.