Leonie Grander
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Leonie Grander has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Samir Abou-Ayash
Department of Prosthodontics and Biomaterials, University Medical Center Mainz, Mainz, Germany
2 shared publicationsAnnika Kraus
Department of Prosthodontics and Biomaterials, University Medical Center Mainz, Mainz, Germany
1 shared publicationFelicitas Hölken
Department of Prosthodontics and Biomaterials, University Medical Center Mainz, Mainz, Germany
1 shared publicationLisa Steiner
Department of Prosthodontics and Biomaterials, University Medical Center Mainz, Mainz, Germany
1 shared publication- Lisa Steiner
Department of Prosthodontics and Material Science, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany.
1 shared publication - Moataz Bayadse
Department of Prosthodontics and Material Science, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany.
1 shared publication
Latest Publications
- Open Access
- 15 August 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1) , 1455
“Influence of macroretention in polymer-infiltrated ceramic network- and zirconia crowns and different roughness values of titanium bases on adhesive bond strength of hybrid abutment crowns: an in vitro study”
Background: Two-piece hybrid abutment crowns (HACs) are CAD/CAM-fabricated implant restorations adhesively bonded to prefabricated titanium bases (Ti-bases). Since adhesive bond represents a potential weakness, methods to enhance long-term durability are being investigated. The aim of this in vitro study was to evaluate the influence of additional macroretention, specifically a circumferential groove, incorporated into polymer-infiltrated ceramic network (PICN) and zirconia crowns, and two Ti-base sandblasting protocols on adhesive bond strength of HACs. Methods: Ninety Ti-bases, 45 zirconia and 45 PICN crowns were divided into six groups ( N = 15). Prior to conventional cementation (Panavia V5, Kuraray) of zirconia control group (Z1), Ti-bases and internal crown surfaces were sandblasted (Al₂O₃; 50 μm; 1.0 bar) and treated with MDP primer. In PICN control group (H1), Ti-bases were sandblasted identically and pretreated with Adiva M-Prime. Internal surfaces of PICN crowns were etched (5% hydrofluoric acid) and primed with Adiva C-Prime. In Z2 and H2, a circular groove in the internal crown surface was prepared as a macroretention in addition to conventional pretreatment as performed in Z1 and H1. Z3 and H3 were also conditioned conventionally, as in Z1 and H1, but Ti-bases were sandblasted with 250 μm at 2.0 bar. After sandblasting, surface roughness values (RV) of Ti-bases were measured. Following thermocycling, tensile shear test was performed, and failure mode was analysed. Mean values were compared using t-test. Results: RV differed significantly between differently blasted Ti-bases ( p < 0.001). Both crown materials achieved significantly higher mean pull-off forces (Z1: 1085 N ± 79; H1 = 664 N ± 68) in control groups than in groups with macroretention (Z2: 1017 N ± 65; H2 = 438 N ± 48) (Z: p = 0.024, H: p < 0.001), and significantly lower pull-off forces than in groups with rougher Ti-bases (Z3: 1298 N ± 98, H3: 744 N ± 64) (Z: p < 0.001, H: p = 0.0023). Conclusions: Increasing pressure and grit size during corundum blasting of Ti-bases can achieve higher pull-off force for zirconia and PICN crowns. Additional macroretention, at least in the form used here, offers no advantage regarding bond strength.
- 15 August 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1) , 1455
Open Access“Influence of macroretention in polymer-infiltrated ceramic network- and zirconia crowns and different roughness values of titanium bases on adhesive bond strength of hybrid abutment crowns: an in vitro study”
Background: Two-piece hybrid abutment crowns (HACs) are CAD/CAM-fabricated implant restorations adhesively bonded to prefabricated titanium bases (Ti-bases). Since adhesive bond represents a potential weakness, methods to enhance long-term durability are being investigated. The aim of this in vitro study was to evaluate the influence of additional macroretention, specifically a circumferential groove, incorporated into polymer-infiltrated ceramic network (PICN) and zirconia crowns, and two Ti-base sandblasting protocols on adhesive bond strength of HACs. Methods: Ninety Ti-bases, 45 zirconia and 45 PICN crowns were divided into six groups ( N = 15). Prior to conventional cementation (Panavia V5, Kuraray) of zirconia control group (Z1), Ti-bases and internal crown surfaces were sandblasted (Al₂O₃; 50 μm; 1.0 bar) and treated with MDP primer. In PICN control group (H1), Ti-bases were sandblasted identically and pretreated with Adiva M-Prime. Internal surfaces of PICN crowns were etched (5% hydrofluoric acid) and primed with Adiva C-Prime. In Z2 and H2, a circular groove in the internal crown surface was prepared as a macroretention in addition to conventional pretreatment as performed in Z1 and H1. Z3 and H3 were also conditioned conventionally, as in Z1 and H1, but Ti-bases were sandblasted with 250 μm at 2.0 bar. After sandblasting, surface roughness values (RV) of Ti-bases were measured. Following thermocycling, tensile shear test was performed, and failure mode was analysed. Mean values were compared using t-test. Results: RV differed significantly between differently blasted Ti-bases ( p < 0.001). Both crown materials achieved significantly higher mean pull-off forces (Z1: 1085 N ± 79; H1 = 664 N ± 68) in control groups than in groups with macroretention (Z2: 1017 N ± 65; H2 = 438 N ± 48) (Z: p = 0.024, H: p < 0.001), and significantly lower pull-off forces than in groups with rougher Ti-bases (Z3: 1298 N ± 98, H3: 744 N ± 64) (Z: p < 0.001, H: p = 0.0023). Conclusions: Increasing pressure and grit size during corundum blasting of Ti-bases can achieve higher pull-off force for zirconia and PICN crowns. Additional macroretention, at least in the form used here, offers no advantage regarding bond strength.
- Open Access
- 4 May 2026
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 12 (1)
Effect of cold atmospheric pressure plasma on wettability of implant prosthetic materials: an in-vitro study
Purpose: Surface wettability is a key factor in bonding of dental materials. The aim of the present study was to investigate the influence of different exposure times of cold atmospheric pressure plasma at constant power on the surface wettability of various dental materials employed in implantology, using the “Piezo-Brush ® ” PZ3 cold atmospheric pressure plasma device. Methods: Seventy-five standardized specimens made of titanium alloy, zirconia, lithium disilicate and polymer-infiltrated hybrid ceramic network were manufactured and polished. Specimens of each material were divided into 5 groups (each n = 15). Four groups were cold atmospheric pressure plasma treated for 5, 10, 20, 30 s and compared to the untreated control group. Surface wettability was assessed by measuring the contact angle of distilled water using a goniometer. Statistical analysis was performed using one-way ANOVA. Results: The mean contact angle was significantly reduced by 60–80% after 5 s of cold atmospheric pressure plasma treatment for all investigated materials ( p < 0.001). Prolonged cold atmospheric pressure plasma exposure resulted in further reduction in mean contact angle values for titanium at each additional treatment duration ( p < 0.001), whereas for lithium disilicate a reduction was observed only up to 10 s. For zirconia and polymer-infiltrated hybrid ceramic network, no further reduction in contact angle was observed beyond 5 s of cold atmospheric pressure plasma treatment. Conclusion: Cold atmospheric pressure plasma treatment significantly increases surface wettability after short exposure times. Within the limitations of this study, these findings may indicate a potential improvement in adhesion behavior. However, under the plasma parameters applied, extending treatment beyond 5 s for zirconia and polymer-infiltrated hybrid ceramic network or beyond 10 s for titanium and lithium disilicate did not result in further reduction of contact angle. The clinical relevance of these findings requires further investigation. Graphical
- 4 May 2026
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 12 (1)
Open AccessEffect of cold atmospheric pressure plasma on wettability of implant prosthetic materials: an in-vitro study
Purpose: Surface wettability is a key factor in bonding of dental materials. The aim of the present study was to investigate the influence of different exposure times of cold atmospheric pressure plasma at constant power on the surface wettability of various dental materials employed in implantology, using the “Piezo-Brush ® ” PZ3 cold atmospheric pressure plasma device. Methods: Seventy-five standardized specimens made of titanium alloy, zirconia, lithium disilicate and polymer-infiltrated hybrid ceramic network were manufactured and polished. Specimens of each material were divided into 5 groups (each n = 15). Four groups were cold atmospheric pressure plasma treated for 5, 10, 20, 30 s and compared to the untreated control group. Surface wettability was assessed by measuring the contact angle of distilled water using a goniometer. Statistical analysis was performed using one-way ANOVA. Results: The mean contact angle was significantly reduced by 60–80% after 5 s of cold atmospheric pressure plasma treatment for all investigated materials ( p < 0.001). Prolonged cold atmospheric pressure plasma exposure resulted in further reduction in mean contact angle values for titanium at each additional treatment duration ( p < 0.001), whereas for lithium disilicate a reduction was observed only up to 10 s. For zirconia and polymer-infiltrated hybrid ceramic network, no further reduction in contact angle was observed beyond 5 s of cold atmospheric pressure plasma treatment. Conclusion: Cold atmospheric pressure plasma treatment significantly increases surface wettability after short exposure times. Within the limitations of this study, these findings may indicate a potential improvement in adhesion behavior. However, under the plasma parameters applied, extending treatment beyond 5 s for zirconia and polymer-infiltrated hybrid ceramic network or beyond 10 s for titanium and lithium disilicate did not result in further reduction of contact angle. The clinical relevance of these findings requires further investigation. Graphical