Eduardo Poblete
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eduardo Poblete has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Marré
Faculty of Medicine Clínica Alemana ‐ Universidad del Desarrollo Santiago Chile
2 shared publications - David Figueroa
Departamento de Traumatología y Ortopedia, Universidad del Desarrollo, Facultad de Medicina Clínica Alemana, Santiago, Chile
2 shared publications - Fernando Martin
Faculty of Medicine Clínica Alemana ‐ Universidad del Desarrollo Santiago Chile
1 shared publication - Francisco Figueroa
Departamento de Traumatología y Ortopedia, Universidad del Desarrollo, Facultad de Medicina Clínica Alemana, Santiago, Chile
1 shared publication - Martín Cañas Prieto
Departamento de Ortopedia y Traumatología, Clínica Alemana de Santiago – Universidad del Desarrollo, Santiago, Chile
1 shared publication - María Loreto Figueroa
Facultad de Medicina Clinica Alemana, Universidad del Desarrollo, Santiago, Chile
1 shared publication
Latest Publications
- Open Access
- 1 July 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (3)
Robotic‐assisted simultaneous bilateral total knee arthroplasty was associated with a more favorable perioperative profile than a historical conventional cohort
Purpose: To compare perioperative, clinical, and functional outcomes between robotic‐assisted and conventional simultaneous bilateral total knee arthroplasty in a historical comparative cohort. Methods: We conducted a retrospective historical comparative cohort study of patients undergoing simultaneous bilateral total knee arthroplasty at a single high‐volume arthroplasty centre between March 2013 and July 2025. Patients were stratified into a historical conventional cohort or a computed tomography‐based robotic‐arm‐assisted cohort. Outcomes included post‐operative haematocrit, blood transfusion, tourniquet ischaemia time, length of stay, post‐operative complications, and Forgotten Joint Score‐12 values. Results: Sixty‐two patients were included: 41 in the robotic‐assisted group and 21 in the conventional group. Baseline preoperative haematocrit was higher in the robotic cohort. Post‐operative haematocrit was higher after robotic‐assisted surgery (31.74 ± 4.81% vs. 26.68 ± 4.41%, p < 0.001), whereas haematocrit drop did not differ significantly ( p = 0.295). The robotic‐assisted group had a lower transfusion requirement (14.6% vs. 76.2%, p < 0.001). After multivariable adjustment, conventional surgery remained associated with increased odds of post‐operative transfusion (adjusted odds ratio 20.78, 95% confidence interval 3.19–135.24). Robotic assistance was also associated with shorter tourniquet ischaemia time and hospital stay. Post‐operative complications occurred only in the conventional cohort, although the difference was not statistically significant. Forgotten Joint Score‐12 values were available for 34 of 62 patients (54.8%) at a median follow‐up of 47.9 months and did not differ significantly between groups (81.06 ± 25.76 vs. 74.83 ± 23.86, p = 0.486). Conclusions: Robotic‐assisted simultaneous bilateral total knee arthroplasty was associated with a more favourable perioperative profile than a historical conventional cohort, particularly regarding transfusion requirement, post‐operative haematocrit, tourniquet ischaemia time, and hospital stay. These findings should be interpreted cautiously because of temporal confounding, incomplete functional follow‐up, and limited sample size. Level of Evidence: Level III.
- 1 July 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (3)
Open AccessRobotic‐assisted simultaneous bilateral total knee arthroplasty was associated with a more favorable perioperative profile than a historical conventional cohort
Purpose: To compare perioperative, clinical, and functional outcomes between robotic‐assisted and conventional simultaneous bilateral total knee arthroplasty in a historical comparative cohort. Methods: We conducted a retrospective historical comparative cohort study of patients undergoing simultaneous bilateral total knee arthroplasty at a single high‐volume arthroplasty centre between March 2013 and July 2025. Patients were stratified into a historical conventional cohort or a computed tomography‐based robotic‐arm‐assisted cohort. Outcomes included post‐operative haematocrit, blood transfusion, tourniquet ischaemia time, length of stay, post‐operative complications, and Forgotten Joint Score‐12 values. Results: Sixty‐two patients were included: 41 in the robotic‐assisted group and 21 in the conventional group. Baseline preoperative haematocrit was higher in the robotic cohort. Post‐operative haematocrit was higher after robotic‐assisted surgery (31.74 ± 4.81% vs. 26.68 ± 4.41%, p < 0.001), whereas haematocrit drop did not differ significantly ( p = 0.295). The robotic‐assisted group had a lower transfusion requirement (14.6% vs. 76.2%, p < 0.001). After multivariable adjustment, conventional surgery remained associated with increased odds of post‐operative transfusion (adjusted odds ratio 20.78, 95% confidence interval 3.19–135.24). Robotic assistance was also associated with shorter tourniquet ischaemia time and hospital stay. Post‐operative complications occurred only in the conventional cohort, although the difference was not statistically significant. Forgotten Joint Score‐12 values were available for 34 of 62 patients (54.8%) at a median follow‐up of 47.9 months and did not differ significantly between groups (81.06 ± 25.76 vs. 74.83 ± 23.86, p = 0.486). Conclusions: Robotic‐assisted simultaneous bilateral total knee arthroplasty was associated with a more favourable perioperative profile than a historical conventional cohort, particularly regarding transfusion requirement, post‐operative haematocrit, tourniquet ischaemia time, and hospital stay. These findings should be interpreted cautiously because of temporal confounding, incomplete functional follow‐up, and limited sample size. Level of Evidence: Level III.
- Open Access
- 1 December 2025
- Published by Georg Thieme Verlag KG in Revista Chilena de Ortopedia y Traumatología
- Vol. 66 (03) , e113-e118
Viscosuplementación con ácido hialurónico en gonartrosis: seguimiento clínico a 9,8 años
Resumen: La eficacia de la viscosuplementación con ácido hialurónico (VAH) en el manejo conservador de la gonartrosis es controvertida. Una serie de casos publicada por nuestro equipo demostró que permitiría una sobrevida libre de artroplastia total de rodilla (ATR) mayor al 80% a 3,6 años. Evaluar los resultados funcionales y la sobrevida libre de prótesis de una cohorte de pacientes con gonartrosis de moderada a severa, manejados con VAH, incorporando el efecto de reinfiltraciones. Conducimos un estudio retrospectivo con pacientes con edad ≥ 60 años con gonartrosis de moderada a severa, ≥ 1 infiltración con AH de alto peso molecular y seguimiento mínimo de 8 años. Se analizaron datos demográficos, clínicos y la necesidad de ATR, y se realizaron pruebas estadísticas pruebas estadísticas de Kaplan-Meier y el Test Exacto de Fisher (p < 0,05). La muestra estuvo compuesta de 85 pacientes (100 rodillas) con edad promedio de 72 años y seguimiento medio de 9,8 ± 0,42 (rango: 8,7–10,50) años. Hubo una tasa de 77% de rodillas infiltradas libres de prótesis, y 52% tuvieron ≥ 2 infiltraciones. La reinyección se asoció significativamente a mayor sobrevida libre de ATR (p = 0,005). Los puntajes medios en la escala Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) para dolor, rigidez y capacidad funcional fueron de 7,1, 2,5 y 20,7, respectivamente. Un total de 19 pacientes (22,4%) requirieron ATR a 4,5 ± 3,1 años de la primera infiltración. No se observaron diferencias en términos de sexo (p = 0,49) ni de edad (p = 0,46) de los pacientes que requirieron ATR. La VAH mostró efectividad sostenida a largo plazo en pacientes ≥ 60 años con gonartrosis de moderada a severa. La reinyección se asoció a mejores resultados y los puntajes WOMAC confirmaron los beneficios funcionales. La VAH es una alternativa conservadora eficaz. IV.
- 1 December 2025
- Published by Georg Thieme Verlag KG in Revista Chilena de Ortopedia y Traumatología
- Vol. 66 (03) , e113-e118
Open AccessViscosuplementación con ácido hialurónico en gonartrosis: seguimiento clínico a 9,8 años
Resumen: La eficacia de la viscosuplementación con ácido hialurónico (VAH) en el manejo conservador de la gonartrosis es controvertida. Una serie de casos publicada por nuestro equipo demostró que permitiría una sobrevida libre de artroplastia total de rodilla (ATR) mayor al 80% a 3,6 años. Evaluar los resultados funcionales y la sobrevida libre de prótesis de una cohorte de pacientes con gonartrosis de moderada a severa, manejados con VAH, incorporando el efecto de reinfiltraciones. Conducimos un estudio retrospectivo con pacientes con edad ≥ 60 años con gonartrosis de moderada a severa, ≥ 1 infiltración con AH de alto peso molecular y seguimiento mínimo de 8 años. Se analizaron datos demográficos, clínicos y la necesidad de ATR, y se realizaron pruebas estadísticas pruebas estadísticas de Kaplan-Meier y el Test Exacto de Fisher (p < 0,05). La muestra estuvo compuesta de 85 pacientes (100 rodillas) con edad promedio de 72 años y seguimiento medio de 9,8 ± 0,42 (rango: 8,7–10,50) años. Hubo una tasa de 77% de rodillas infiltradas libres de prótesis, y 52% tuvieron ≥ 2 infiltraciones. La reinyección se asoció significativamente a mayor sobrevida libre de ATR (p = 0,005). Los puntajes medios en la escala Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) para dolor, rigidez y capacidad funcional fueron de 7,1, 2,5 y 20,7, respectivamente. Un total de 19 pacientes (22,4%) requirieron ATR a 4,5 ± 3,1 años de la primera infiltración. No se observaron diferencias en términos de sexo (p = 0,49) ni de edad (p = 0,46) de los pacientes que requirieron ATR. La VAH mostró efectividad sostenida a largo plazo en pacientes ≥ 60 años con gonartrosis de moderada a severa. La reinyección se asoció a mejores resultados y los puntajes WOMAC confirmaron los beneficios funcionales. La VAH es una alternativa conservadora eficaz. IV.