Lijuan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lijuan Wang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Hulin Zhao
Senior Department of Neurosurgery, Chinese PLA General Hospital, Beijing, China
1 shared publication - Jianning Zhang
Senior Department of Neurosurgery, Chinese PLA General Hospital, Beijing 100853, China
1 shared publication - Jiayu Liu
Senior Department of Neurosurgery, Chinese PLA General Hospital, Beijing 100853, China
1 shared publication - Xiangyang Bao
Department of Neurosurgery, the Fifth Medical Centre, Chinese PLA General Hospital, Beijing, China
1 shared publication - Xudong Shi
Medical School of Chinese PLA, Beijing, China; Department of Neurosurgery, The First Medical Center of the Chinese PLA General Hospital, Beijing, China
1 shared publication - Yuanyuan Dang
Department of Neurosurgery, Chinese PLA General Hospital, Beijing 100853, China
1 shared publication
Latest Publications
- Open Access
- 1 May 2026
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 69 (3) , 459-471
The Feasibility, Accuracy and Safety of Robot-Assisted Ventriculoperitoneal Shunt
Objective : Ventriculoperitoneal shunt (VPS) treats hydrocephalus effectively, but manual ventricular catheter placement has a high misplacement rate. This study assesses the feasibility, accuracy, and safety of robot-assisted VPS.Methods : A retrospective analysis was performed on the clinical data of 87 patients from 2022 to 2024, with 42 receiving robot-assisted VPS and 45 receiving conventional manual VPS. Logistic regression analysis was performed to identify risk factors affecting placement accuracy.Results : The robot-assisted cohort showed smaller bilateral frontal horn diameters and a lower Evans index (p<0.05). It achieved higher placement accuracy, required fewer puncture attempts, and had a lower postoperative complication rate (p0.05). Logistic regression analysis confirmed robot-assistance as a key factor for accurate catheter placement (odds ratio, 6.52; p<0.001).Conclusion : Robot-assisted VPS achieves precise placement, reduces puncture attempts and complications, and does not increase time costs, confirming its clinical feasibility, accuracy, and safety.
- 1 May 2026
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 69 (3) , 459-471
Open AccessThe Feasibility, Accuracy and Safety of Robot-Assisted Ventriculoperitoneal Shunt
Objective : Ventriculoperitoneal shunt (VPS) treats hydrocephalus effectively, but manual ventricular catheter placement has a high misplacement rate. This study assesses the feasibility, accuracy, and safety of robot-assisted VPS.Methods : A retrospective analysis was performed on the clinical data of 87 patients from 2022 to 2024, with 42 receiving robot-assisted VPS and 45 receiving conventional manual VPS. Logistic regression analysis was performed to identify risk factors affecting placement accuracy.Results : The robot-assisted cohort showed smaller bilateral frontal horn diameters and a lower Evans index (p<0.05). It achieved higher placement accuracy, required fewer puncture attempts, and had a lower postoperative complication rate (p0.05). Logistic regression analysis confirmed robot-assistance as a key factor for accurate catheter placement (odds ratio, 6.52; p<0.001).Conclusion : Robot-assisted VPS achieves precise placement, reduces puncture attempts and complications, and does not increase time costs, confirming its clinical feasibility, accuracy, and safety.