Chrysoula Moustou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Chrysoula Moustou has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Antonios A. Argyris
National and Kapodistrian University of Athens
1 shared publication - Athanassios D. Protogerou
National and Kapodistrian University of Athens
1 shared publication - Christina Konstantaki
Department of Clinical Therapeutics, School of Medicine, National and Kapodistrian University of Athens, Greece
1 shared publication - Evaggelia K. Aissopou
Cardiovascular Prevention and Research Unit, Clinic/Laboratory of Pathophysiology, School of Medicine, National and Kapodistrian University of Athens, 115 27 Athens, Greece
1 shared publication - Georgios Zervas
Angiology and Endothelial Pathophysiology Unit, Department of Clinical Therapeutics, School of Medicine, Alexandra Hospital, National and Kapodistrian University of Athens, 115 28 Athens, Greece
1 shared publication - Irini Chatziralli
2nd Department of Ophthalmology, Panepistemiako Geniko Nosokomeio Attikon, National and Kapodistrian University of Athens, 12462 Athens, Greece
1 shared publication
Latest Publications
- Open Access
Quantitative Comparison of a Handheld and a Table-Top Fundus Camera for Retinal Microvascular Assessment
Objectives: The aim of this study was to compare a widely applied table-top digital non-mydriatic camera (Topcon TRC-NW-8) with a handheld digital non-mydriatic camera (Optomed Aurora IQ) regarding the quantitative assessment of the retinal microcirculation using established biomarkers: central retinal arteriolar equivalent (CRAE), central retinal venular equivalent (CRVE) and arterio-venous ratio (AVR). Methods: The present cross-sectional study included 26 randomly selected participants (51 eyes) who underwent retinal imaging of both eyes with the two devices and were analyzed using a static retinal vessel analyzer. Results: The mean differences in CRAE, CRVE and AVR between the two devices (Topcon/Aurora) were 24.96 ± 11.7, 22.7 ± 11.7 and 0.026 ± 0.045, respectively. Strong correlations were observed between devices (r = 0.84 for CRAE, 0.75 for CRVE and 0.83 for AVR; all p < 0.001), with high agreement as indicated by ICC values (0.91, 0.85, and 0.90, respectively). Bland–Altman plots indicated evidence of systemic bias (95% within 2 SD) with no proportional bias, as the differences were consistently distributed across the range of average values. Regression-based equations were derived to approximate the transformation of measurements between devices. Conclusions: The handheld fundus camera demonstrates strong correlation and good relative agreement with the table-top device; however, a consistent device-dependent bias limits the direct interchangeability of absolute measurements. The derived transformation equations may facilitate approximate cross-device comparison, although external validation is required. These findings support the complementary use of handheld devices and highlight the need for calibration strategies when integrating measurements across platforms.
Open AccessQuantitative Comparison of a Handheld and a Table-Top Fundus Camera for Retinal Microvascular Assessment
Objectives: The aim of this study was to compare a widely applied table-top digital non-mydriatic camera (Topcon TRC-NW-8) with a handheld digital non-mydriatic camera (Optomed Aurora IQ) regarding the quantitative assessment of the retinal microcirculation using established biomarkers: central retinal arteriolar equivalent (CRAE), central retinal venular equivalent (CRVE) and arterio-venous ratio (AVR). Methods: The present cross-sectional study included 26 randomly selected participants (51 eyes) who underwent retinal imaging of both eyes with the two devices and were analyzed using a static retinal vessel analyzer. Results: The mean differences in CRAE, CRVE and AVR between the two devices (Topcon/Aurora) were 24.96 ± 11.7, 22.7 ± 11.7 and 0.026 ± 0.045, respectively. Strong correlations were observed between devices (r = 0.84 for CRAE, 0.75 for CRVE and 0.83 for AVR; all p < 0.001), with high agreement as indicated by ICC values (0.91, 0.85, and 0.90, respectively). Bland–Altman plots indicated evidence of systemic bias (95% within 2 SD) with no proportional bias, as the differences were consistently distributed across the range of average values. Regression-based equations were derived to approximate the transformation of measurements between devices. Conclusions: The handheld fundus camera demonstrates strong correlation and good relative agreement with the table-top device; however, a consistent device-dependent bias limits the direct interchangeability of absolute measurements. The derived transformation equations may facilitate approximate cross-device comparison, although external validation is required. These findings support the complementary use of handheld devices and highlight the need for calibration strategies when integrating measurements across platforms.