Yanan Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yanan Zhang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Shijie Wang
Institute of Applied Mathematics
2 shared publications - Shikang Meng
Institute of Applied Mathematics, Hebei Academy of Sciences
2 shared publications - Yu Cheng
Information Security Authentication Technology Innovation Center of Hebei Province, Hebei Academy of Sciences, Institute of Applied Mathematics, Shijiazhuang, China
2 shared publications - Zhiqiang Wang
Institute of Applied Mathematics, Hebei Academy of Sciences
2 shared publications - Yaheng Ren
Institute of Applied Mathematics, Hebei Academy of Sciences, Shijiazhuang 050081, China
1 shared publication - Yaheng Ren
Institute of Applied Mathematics, Hebei Academy of Sciences
1 shared publication
Latest Publications
- Open Access
- 6 May 2026
- Published by Elsevier in SSRN Electronic Journal
Automatic High-Precision Calibration of Camera Intrinsic Parameters Based on Adaptive Exposure and Multi-Pose Collaboration
Camera calibration is the fundamental core link in the field of machine vision, and the calibration accuracy directly determines the upper limit of subsequent visual tasks. This paper proposes an automated high-precision internal parameter calibration method for cameras that combines adaptive exposure adjustment and multi pose collaboration to address the problems of traditional camera calibration processes being cumbersome, easily affected by environmental light fluctuations and the randomness of calibration plate pose adjustments, and poor stability of calibration results due to insufficient corner point extraction accuracy. This method first constructs a brightness evaluation standard based on the average grayscale value of the calibration image area, and designs an adaptive exposure adjustment algorithm with grayscale feedback compensation to stabilize the grayscale value of the calibration image in the optimal range; Secondly, the strategy of integrating Harris corner detection and grayscale centroid method is adopted to achieve high-precision extraction of calibration board corner points from pixel level coarse positioning to sub-pixel level refinement; Finally, combined with high-precision pose control of the robotic arm, a standardized calibration pose set is designed to achieve automatic acquisition of multi pose images of the calibration board. The experimental results show that the reprojection error of the proposed method is as low as 0.06 pixels, and the camera intrinsic parameter coefficient of variation is less than 6%. Compared with traditional calibration methods, this method has significant advantages in stability, robustness, and universality, and can provide reliable camera parameter support for industrial measurement, 3D reconstruction, and other fields.
- 6 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAutomatic High-Precision Calibration of Camera Intrinsic Parameters Based on Adaptive Exposure and Multi-Pose Collaboration
Camera calibration is the fundamental core link in the field of machine vision, and the calibration accuracy directly determines the upper limit of subsequent visual tasks. This paper proposes an automated high-precision internal parameter calibration method for cameras that combines adaptive exposure adjustment and multi pose collaboration to address the problems of traditional camera calibration processes being cumbersome, easily affected by environmental light fluctuations and the randomness of calibration plate pose adjustments, and poor stability of calibration results due to insufficient corner point extraction accuracy. This method first constructs a brightness evaluation standard based on the average grayscale value of the calibration image area, and designs an adaptive exposure adjustment algorithm with grayscale feedback compensation to stabilize the grayscale value of the calibration image in the optimal range; Secondly, the strategy of integrating Harris corner detection and grayscale centroid method is adopted to achieve high-precision extraction of calibration board corner points from pixel level coarse positioning to sub-pixel level refinement; Finally, combined with high-precision pose control of the robotic arm, a standardized calibration pose set is designed to achieve automatic acquisition of multi pose images of the calibration board. The experimental results show that the reprojection error of the proposed method is as low as 0.06 pixels, and the camera intrinsic parameter coefficient of variation is less than 6%. Compared with traditional calibration methods, this method has significant advantages in stability, robustness, and universality, and can provide reliable camera parameter support for industrial measurement, 3D reconstruction, and other fields.