Yin Hlaing Min
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yin Hlaing Min has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Arkar Htet
Lincoln University College, Malaysia
2 shared publications Sui Reng Liana
Lincoln University College, Malayisa
2 shared publications- Theingi Aung
Lincoln University College, Malayisa
2 shared publications Om Prakash Giri
Pokhara University, Nepal
1 shared publication- Zakir Hossen Shaikh
Department of Finance and Accounting, College of Business Administration, Kingdom University, Riffa P.O. Box 40434, Bahrain
1 shared publication
Latest Publications
- 30 June 2026
- Published by IGI Global Scientific Publishing
- p. 277-312
Developing a Façade Risk Evaluation Framework (F-REF) Based on Failure Mode and Effects Analysis (FMEA)
This chapter develops a Façade Risk Evaluation Framework (F-REF) grounded in Failure Mode and Effects Analysis (FMEA) for the systematic identification, comparison, and prioritization of façade risks across design, construction, and operation. The framework extends conventional FMEA through façade-specific severity, occurrence, and detection rubrics for unitized curtain walls and ventilated rainscreen systems; a façade-weighted priority index used alongside the traditional Risk Priority Number; dependency-based treatment of coupled failures; and full-matrix application across three façade scenarios with sensitivity testing under alternative weighting schemes. The chapter also positions F-REF against Fault Tree Analysis, Event Tree Analysis, Bow-Tie analysis, and qualitative checklist methods. Although further expert calibration is needed, the framework provides a more rigorous and actionable basis for façade risk screening, inspection planning, and lifecycle decision support.
- 30 June 2026
- Published by IGI Global Scientific Publishing
- p. 277-312
Developing a Façade Risk Evaluation Framework (F-REF) Based on Failure Mode and Effects Analysis (FMEA)
This chapter develops a Façade Risk Evaluation Framework (F-REF) grounded in Failure Mode and Effects Analysis (FMEA) for the systematic identification, comparison, and prioritization of façade risks across design, construction, and operation. The framework extends conventional FMEA through façade-specific severity, occurrence, and detection rubrics for unitized curtain walls and ventilated rainscreen systems; a façade-weighted priority index used alongside the traditional Risk Priority Number; dependency-based treatment of coupled failures; and full-matrix application across three façade scenarios with sensitivity testing under alternative weighting schemes. The chapter also positions F-REF against Fault Tree Analysis, Event Tree Analysis, Bow-Tie analysis, and qualitative checklist methods. Although further expert calibration is needed, the framework provides a more rigorous and actionable basis for façade risk screening, inspection planning, and lifecycle decision support.
- 30 June 2026
- Published by IGI Global Scientific Publishing
- p. 129-160
Lifecycle Assessment of Aluminium Composite Panel Façades in Tropical and Temperate Climates
This chapter develops a durability-informed lifecycle assessment perspective for aluminium composite panel (ACP) façades in tropical and temperate climates. It argues that ACP sustainability cannot be judged by initial embodied carbon alone, because climatic exposure influences coating degradation, corrosion risk, sealant ageing, moisture ingress, maintenance frequency, service life, and end-of-life recovery. Tropical climates tend to intensify humidity-, rainfall-, UV-, and corrosion-related deterioration, while temperate climates present challenges associated with thermal movement, freeze-thaw exposure, sealant fatigue, and seasonal moisture management. The chapter integrates lifecycle assessment, façade durability science, and green building certification implications to show that ACP façade sustainability is a dynamic whole-life performance outcome. It concludes that more reliable assessment requires climate-sensitive durability assumptions, preventive maintenance planning, realistic recycling pathways, and transparent environmental documentation.
- 30 June 2026
- Published by IGI Global Scientific Publishing
- p. 129-160
Lifecycle Assessment of Aluminium Composite Panel Façades in Tropical and Temperate Climates
This chapter develops a durability-informed lifecycle assessment perspective for aluminium composite panel (ACP) façades in tropical and temperate climates. It argues that ACP sustainability cannot be judged by initial embodied carbon alone, because climatic exposure influences coating degradation, corrosion risk, sealant ageing, moisture ingress, maintenance frequency, service life, and end-of-life recovery. Tropical climates tend to intensify humidity-, rainfall-, UV-, and corrosion-related deterioration, while temperate climates present challenges associated with thermal movement, freeze-thaw exposure, sealant fatigue, and seasonal moisture management. The chapter integrates lifecycle assessment, façade durability science, and green building certification implications to show that ACP façade sustainability is a dynamic whole-life performance outcome. It concludes that more reliable assessment requires climate-sensitive durability assumptions, preventive maintenance planning, realistic recycling pathways, and transparent environmental documentation.