Aurora Corso
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aurora Corso has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Dassie
Medical Physics Department, Centro di Riferimento Oncologico di Aviano IRCCS, 33081 Aviano, Italy
2 shared publications - Michele Avanzo
Centro di Riferimento Oncologico di Aviano IRCCS
2 shared publications - Christian Micheloni
Università degli Studi di Udine
1 shared publication - Cristian Deana
Medical Physics Department, Centro di Riferimento Oncologico di Aviano IRCCS, 33081 Aviano, Italy
1 shared publication - Cristina Cappelletto
Medical Physics Department, Centro di Riferimento Oncologico di Aviano IRCCS, 33081 Aviano, Italy
1 shared publication - Giuseppe Fanetti
Division of Radiation Oncology, Centro di Riferimento Oncologico di Aviano (CRO) IRCCS, 33081 Aviano, Italy
1 shared publication
Latest Publications
- Open Access
Validation of Synthetic Megavoltage Computed Tomography (MVCT) for Dose Calculation in Radiotherapy Treatment Planning
Background/Objectives: Dental metallic implants cause severe streaking artifacts in kilovoltage CT (kVCT), compromising dose calculation in radiotherapy (RT) treatment planning. The purpose of this study is to assess the dosimetric agreement of synthetic MVCT (sMVCT) images generated from artifact-affected kVCT using a deep learning network with respect to true MVCT (tMVCT) acquired at the treatment machine. Methods: Nineteen head and neck cancer patients with dental metallic implants treated with RT were included. Planning kVCT images were converted to sMVCT using Metal Artifact Reduction through Domain Transformation Network (MAR-DTN), a UNet-inspired deep learning network. The sMVCT images were rigidly registered to true MVCT (tMVCT) acquired on the Hi-Art II Tomotherapy system. Mean Hounsfield Unit (HU) values were compared across seven structures (thyroid, bilateral parotids, brainstem, spinal cord, GTV, PTV70) using pairwise Wilcoxon tests and Two One-Sided Tests (TOST) for statistical equivalence within a pre-specified margin of ±20 HU (corresponding to a 2% deviation in physical density). Dose distributions were recalculated on sMVCT using the AAA algorithm and compared to reference tMVCT-based plans via dose–volume histogram (DVH) metrics, evaluated for equivalence by TOST within a margin of ±2% of the prescribed dose (±142 cGy of 70.95 Gy), and via 3D gamma index, evaluated by one-sided non-inferiority test against the clinically accepted thresholds of 90% (2 mm/2%) and 95% (3 mm/3%). A pre-specified sensitivity analysis was performed by repeating all comparisons on the strictly independent sub-cohort (n = 16) excluding three patients drawn from the MAR-DTN training set. Results: All seven anatomical structures showed statistical equivalence between sMVCT and tMVCT under the ±20 HU margin (TOST p < 0.05; mean HU differences in the range −1.1 to +8.4 HU; all Wilcoxon p > 0.05). All nine DVH metrics achieved formal dosimetric equivalence within ±2% of the prescribed dose (TOST p < 0.05). Mean 3D gamma pass rates were 94.3% (95% CI: 89.3–97.1) for the 2 mm/2% criterion and 97.6% (95% CI: 94.8–99.0) for the 3 mm/3% criterion, both formally non-inferior to the respective clinical thresholds (p < 0.0001). Residual gamma failures were concentrated at the patient surface, consistent with inter-session repositioning uncertainty rather than errors in synthetic image generation. Sensitivity analysis on the n = 16 sub-cohort confirmed all conclusions, with mean HU and DVH differences smaller than in the full cohort for the structures showing the largest mean differences, and comparable for the remaining structures, with all TOST equivalence and gamma non-inferiority tests confirmed in both cohorts. Conclusions: sMVCT images generated via MAR-DTN show dosimetric agreement with physically acquired tMVCT in head and neck patients with dental implants, formally demonstrated by TOST equivalence within ±2% of prescribed dose for all DVH metrics. The combined HU and gamma index framework presented here represents a promising quality assurance approach for AI-based synthetic imaging tools in radiotherapy, pending validation in larger prospective multicentre cohorts.
Open AccessValidation of Synthetic Megavoltage Computed Tomography (MVCT) for Dose Calculation in Radiotherapy Treatment Planning
Background/Objectives: Dental metallic implants cause severe streaking artifacts in kilovoltage CT (kVCT), compromising dose calculation in radiotherapy (RT) treatment planning. The purpose of this study is to assess the dosimetric agreement of synthetic MVCT (sMVCT) images generated from artifact-affected kVCT using a deep learning network with respect to true MVCT (tMVCT) acquired at the treatment machine. Methods: Nineteen head and neck cancer patients with dental metallic implants treated with RT were included. Planning kVCT images were converted to sMVCT using Metal Artifact Reduction through Domain Transformation Network (MAR-DTN), a UNet-inspired deep learning network. The sMVCT images were rigidly registered to true MVCT (tMVCT) acquired on the Hi-Art II Tomotherapy system. Mean Hounsfield Unit (HU) values were compared across seven structures (thyroid, bilateral parotids, brainstem, spinal cord, GTV, PTV70) using pairwise Wilcoxon tests and Two One-Sided Tests (TOST) for statistical equivalence within a pre-specified margin of ±20 HU (corresponding to a 2% deviation in physical density). Dose distributions were recalculated on sMVCT using the AAA algorithm and compared to reference tMVCT-based plans via dose–volume histogram (DVH) metrics, evaluated for equivalence by TOST within a margin of ±2% of the prescribed dose (±142 cGy of 70.95 Gy), and via 3D gamma index, evaluated by one-sided non-inferiority test against the clinically accepted thresholds of 90% (2 mm/2%) and 95% (3 mm/3%). A pre-specified sensitivity analysis was performed by repeating all comparisons on the strictly independent sub-cohort (n = 16) excluding three patients drawn from the MAR-DTN training set. Results: All seven anatomical structures showed statistical equivalence between sMVCT and tMVCT under the ±20 HU margin (TOST p < 0.05; mean HU differences in the range −1.1 to +8.4 HU; all Wilcoxon p > 0.05). All nine DVH metrics achieved formal dosimetric equivalence within ±2% of the prescribed dose (TOST p < 0.05). Mean 3D gamma pass rates were 94.3% (95% CI: 89.3–97.1) for the 2 mm/2% criterion and 97.6% (95% CI: 94.8–99.0) for the 3 mm/3% criterion, both formally non-inferior to the respective clinical thresholds (p < 0.0001). Residual gamma failures were concentrated at the patient surface, consistent with inter-session repositioning uncertainty rather than errors in synthetic image generation. Sensitivity analysis on the n = 16 sub-cohort confirmed all conclusions, with mean HU and DVH differences smaller than in the full cohort for the structures showing the largest mean differences, and comparable for the remaining structures, with all TOST equivalence and gamma non-inferiority tests confirmed in both cohorts. Conclusions: sMVCT images generated via MAR-DTN show dosimetric agreement with physically acquired tMVCT in head and neck patients with dental implants, formally demonstrated by TOST equivalence within ±2% of prescribed dose for all DVH metrics. The combined HU and gamma index framework presented here represents a promising quality assurance approach for AI-based synthetic imaging tools in radiotherapy, pending validation in larger prospective multicentre cohorts.