AZArtyom E. Zemtsov

Artyom E. Zemtsov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Artyom E. Zemtsov has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Study of the design and fabrication characteristics of silicon-based detectors using two-photon absorption

    by Artyom A. Sharapov, Alexey V. Sidelev, Konstantin I. Tapero, Alexander S. Vatuev, Artyom E. Zemtsov

    This paper describes the fabrication technology and design of the developed monolithic semiconductor position-sensitive detectors. A distinguishing feature of these structures is their small pixel size (approximately 15 × 15 μm). The results of experimental studies of the detectors are presented, including measurements of the electrical characteristics of the fabricated semiconductor structures in the form of bare dies of semiconductor ICs and an analysis of the uniformity of the detectors’ sensing arrays using laser irradiation. The advantages and disadvantages of the developed detectors are compared with those of commercially used position-sensitive detectors. A method based on focused laser irradiation in the two-photon absorption regime was proposed and tested on the developed detectors to investigate the depth of regions sensitive to ionizing radiation. Factors affecting estimates of the sensitivity of semiconductor structures obtained using focused laser irradiation in multiphoton absorption regimes are discussed.

  • Open Access

    Study of the sensitivity of semiconductor pixel structures using focused laser irradiation

    by Artyom A. Sharapov, Alexey V. Sidelev, Konstantin I. Tapero, Artyom E. Zemtsov

    Results of focused laser irradiation of semiconductor structures having relatively small sizes of discrete components on the crystal were presented. Different laser beam depth profiles were obtained in the experiments via different lenses. The focused beam size was varied in a range of 1.4 to 3.6 μm at the beam waist. The test specimens were position-sensitive detectors with small pixel size (~15 μm). We showed that the use of different lenses with constant pulse energy and duration yields different results in sensitivity assessment. Conclusions were made as about the limitations in the application of precision irradiation methods to semiconductor structure.