Shiyu Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shiyu Yang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Hanqing Chen
Tianjin University
3 shared publications - Mengyu Li
Tianjin University
3 shared publications - Ruiqi Wang
Tianjin University
3 shared publications - Wei Li
School of Electrical and Information Engineering, Tianjin University, Tianjin, China
3 shared publications - Chao Ma
School of Electrical and Information Engineering, Tianjin University, Tianjin, China
2 shared publications - Xiaoquan Gong2 shared publications
Latest Publications
- Open Access
- 23 July 2026
- Published by Elsevier in SSRN Electronic Journal
A Multi-Signal Fusion Method for Wet Gas Measurement Based on a Modified Swirl Flowmeter
Accurate measurement of gas-liquid two-phase flow is critical for industrial production, yet traditional swirl flowmeters struggle to resolve the wet gas using a single frequency signal. To address this issue, we propose a multi-signal fusion measurement method based on a structurally refined swirl flowmeter. Firstly, single-phase water calibration experiments were conducted to investigate and select the structural parameters of the swirl generator (blade count, blade angle, and tail-cut angle) based on the instrument coefficient and effective measurement range. Secondly, numerical simulations were performed to reveal the physical mechanisms of liquid-phase interference by analyzing the evolution of internal static pressure and velocity fields under varying liquid volume fractions. Finally, extensive wet steam experiments were carried out using a condensation-weighing steam flow standard facility at the Yantai National Metrology Institute, covering gas-phase Froude numbers Frg from 0.71 to 3.33 and dryness fractions X from 0.9 to 1.0. The relationships among the under-reading UR coefficient, differential pressure ratio, dryness X, and gas Froude number Frg were systematically investigated. Consequently, a novel dual-parameter measurement model coupling UR and the differential pressure ratio was established. Experimental validation demonstrates that the proposed model achieves high accuracy: at a 95% confidence level, the relative errors for the dryness fraction and gas mass flow rate are controlled within 3.5% and 3.94%, respectively, with mean absolute percentage errors of 1.29% and 1.86%. This work provides an effective and highly precise approach for wet gas measurement.
- 23 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Multi-Signal Fusion Method for Wet Gas Measurement Based on a Modified Swirl Flowmeter
Accurate measurement of gas-liquid two-phase flow is critical for industrial production, yet traditional swirl flowmeters struggle to resolve the wet gas using a single frequency signal. To address this issue, we propose a multi-signal fusion measurement method based on a structurally refined swirl flowmeter. Firstly, single-phase water calibration experiments were conducted to investigate and select the structural parameters of the swirl generator (blade count, blade angle, and tail-cut angle) based on the instrument coefficient and effective measurement range. Secondly, numerical simulations were performed to reveal the physical mechanisms of liquid-phase interference by analyzing the evolution of internal static pressure and velocity fields under varying liquid volume fractions. Finally, extensive wet steam experiments were carried out using a condensation-weighing steam flow standard facility at the Yantai National Metrology Institute, covering gas-phase Froude numbers Frg from 0.71 to 3.33 and dryness fractions X from 0.9 to 1.0. The relationships among the under-reading UR coefficient, differential pressure ratio, dryness X, and gas Froude number Frg were systematically investigated. Consequently, a novel dual-parameter measurement model coupling UR and the differential pressure ratio was established. Experimental validation demonstrates that the proposed model achieves high accuracy: at a 95% confidence level, the relative errors for the dryness fraction and gas mass flow rate are controlled within 3.5% and 3.94%, respectively, with mean absolute percentage errors of 1.29% and 1.86%. This work provides an effective and highly precise approach for wet gas measurement.
- Open Access
- 9 May 2026
- Published by Elsevier in SSRN Electronic Journal
A Multi-Signal Fusion Method for Wet Gas Measurement Based on a Modified Swirl Flowmeter
Accurate measurement of gas-liquid two-phase flow is critical for industrial production, yet traditional swirl flowmeters struggle to resolve the wet gas using a single frequency signal. To address this issue, we propose a multi-signal fusion measurement method based on an optimized swirl flowmeter. Firstly, single-phase water calibration experiments were conducted to optimize the structural parameters of the swirl generator (blade count, blade angle, and tail-cut angle) based on the instrumentation coefficient and effective measurement range. Secondly, numerical simulations were performed to reveal the physical mechanisms of liquid-phase interference by analyzing the evolution of internal static pressure and velocity fields under varying liquid volume fractions. Finally, extensive wet steam experiments were carried out using a condensation-weighing steam flow standard facility at the Yantai National Metrology Institute. The relationships among the under-reading UR coefficient, differential pressure ratio, dryness X, and gas Froude number Fr_g were systematically investigated. Consequently, a novel dual-parameter measurement model coupling UR and the differential pressure ratio was established. Experimental validation demonstrates that the proposed model achieves high accuracy: at a 95% confidence level, the relative errors for the dryness fraction and gas mass flow rate are controlled within 3.5% and 3.94%, respectively. This work provides an effective and highly precise approach for wet gas measurement.
- 9 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Multi-Signal Fusion Method for Wet Gas Measurement Based on a Modified Swirl Flowmeter
Accurate measurement of gas-liquid two-phase flow is critical for industrial production, yet traditional swirl flowmeters struggle to resolve the wet gas using a single frequency signal. To address this issue, we propose a multi-signal fusion measurement method based on an optimized swirl flowmeter. Firstly, single-phase water calibration experiments were conducted to optimize the structural parameters of the swirl generator (blade count, blade angle, and tail-cut angle) based on the instrumentation coefficient and effective measurement range. Secondly, numerical simulations were performed to reveal the physical mechanisms of liquid-phase interference by analyzing the evolution of internal static pressure and velocity fields under varying liquid volume fractions. Finally, extensive wet steam experiments were carried out using a condensation-weighing steam flow standard facility at the Yantai National Metrology Institute. The relationships among the under-reading UR coefficient, differential pressure ratio, dryness X, and gas Froude number Fr_g were systematically investigated. Consequently, a novel dual-parameter measurement model coupling UR and the differential pressure ratio was established. Experimental validation demonstrates that the proposed model achieves high accuracy: at a 95% confidence level, the relative errors for the dryness fraction and gas mass flow rate are controlled within 3.5% and 3.94%, respectively. This work provides an effective and highly precise approach for wet gas measurement.