Han Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Han Zhang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Dakun Lai
School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
1 shared publication - Hongyou Zuo
Glasgow College, University of Electronic Science and Technology of China, Chengdu 611731, China
1 shared publication - Jiahui Cheng
University of Electronic Science and Technology of China, Chengdu, China
1 shared publication - Yukun Ren
Glasgow College, University of Electronic Science and Technology of China, Chengdu 611731, China
1 shared publication
Latest Publications
- Open Access
- 21 December 2025
- Published by Association for Computing Machinery (ACM)
- p. 149-153
Lightweight Fused Siamese CNN for Multi-Modal Cardiac Anomaly Detection from ECG and PCG Spectrograms
Electrocardiogram (ECG) and phonocardiogram (PCG) are critical for the early prevention and diagnosis of cardiovascular diseases (CVDs). With the rapid advancement of deep learning techniques, automated CVD detection from these signals has attracted considerable research attention. However, existing methods are predominantly based on unimodal data, failing to leverage the complementary electrophysiological and mechanical information. Furthermore, current multi-modal fusion strategies, often employing separate encoders, suffer from parameter redundancy, high computational complexity, and ineffective cross-modal feature alignment in the latent space. It is therefore crucial to develop an efficient multi-modal learning method for accurate and deployable CVD screening. In this study, we propose a novel Lightweight Fused Siamese Convolutional Neural Network (LFS-CNN) for cardiac anomaly detection from synchronized ECG and PCG signals. Our model employs a weight-shared siamese backbone to process time-frequency representations of both modalities, facilitating the learning of modality-invariant features while dramatically reducing parameters. An R-peak anchored data augmentation strategy is also designed to ensure physiological consistency. Experimental results on the PhysioNet/CinC Challenge 2016 dataset demonstrate that the performance of our proposed LFS-CNN is superior to those of unimodal methods and conventional fusion alternatives. Our fused model achieves an F1-score of 97.02%, an accuracy of 95.83%, and a sensitivity of 97.13%, while significantly enhancing the specificity of the PCG model from 62.50% to 92.50%, validating its effectiveness and strong potential for deployment in wearable cardiac monitoring systems.
- 21 December 2025
- Published by Association for Computing Machinery (ACM)
- p. 149-153
Open AccessLightweight Fused Siamese CNN for Multi-Modal Cardiac Anomaly Detection from ECG and PCG Spectrograms
Electrocardiogram (ECG) and phonocardiogram (PCG) are critical for the early prevention and diagnosis of cardiovascular diseases (CVDs). With the rapid advancement of deep learning techniques, automated CVD detection from these signals has attracted considerable research attention. However, existing methods are predominantly based on unimodal data, failing to leverage the complementary electrophysiological and mechanical information. Furthermore, current multi-modal fusion strategies, often employing separate encoders, suffer from parameter redundancy, high computational complexity, and ineffective cross-modal feature alignment in the latent space. It is therefore crucial to develop an efficient multi-modal learning method for accurate and deployable CVD screening. In this study, we propose a novel Lightweight Fused Siamese Convolutional Neural Network (LFS-CNN) for cardiac anomaly detection from synchronized ECG and PCG signals. Our model employs a weight-shared siamese backbone to process time-frequency representations of both modalities, facilitating the learning of modality-invariant features while dramatically reducing parameters. An R-peak anchored data augmentation strategy is also designed to ensure physiological consistency. Experimental results on the PhysioNet/CinC Challenge 2016 dataset demonstrate that the performance of our proposed LFS-CNN is superior to those of unimodal methods and conventional fusion alternatives. Our fused model achieves an F1-score of 97.02%, an accuracy of 95.83%, and a sensitivity of 97.13%, while significantly enhancing the specificity of the PCG model from 62.50% to 92.50%, validating its effectiveness and strong potential for deployment in wearable cardiac monitoring systems.