Nisha Kumari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nisha Kumari has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- G. Lloyds Raja
National Institute of Technology Patna
1 shared publication - Pulakraj Aryan
Department of Electrical Engineering, Manipal University Jaipur, Jaipur, Rajasthan, India
1 shared publication - Vivek Kumar
Department of Electrical Engineering, Indian Institute of Technology Roorkee, Uttarakhand, India
1 shared publication - Yogesh Vijay Hote
Indian Institute of Technology Roorkee
1 shared publication
Latest Publications
- Open Access
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 71475-71493
Performance and Robustness Analysis of Optimal T2FID+PD Controller for Frequency Regulation in a Triple-Area Deregulated Power System
An enhanced type-2 fuzzy integral–derivative plus proportional-derivative (T2FID+PD) controller is suggested for mitigating frequency deviations in a triple-area hybrid power system (HPS). Optimal controller settings are computed using the African vulture optimizer (AVO). The thermal PS & distributed renewable generation (DRG) are interconnected in Area-1. This DRG unit comprises wind-turbine & solar-photovoltaic generation. The thermal & gas and thermal & nuclear facilities are interconnected in Area-2 and Area-3, respectively. The nonlinearities, including generation rate constraints (GRC), boiler dynamics (BD), and governor dead band (GDB), are also modeled. Moreover, the performance evaluation of an AVO-based tuned T2FID+PD control is compared with its contemporaries. Also, the effect of integrating electric vehicles is studied. Additionally, the developed controller's robustness to parameter variations in power systems is ascertained. Finally, the impact of deregulation is studied by simulating nominal, unilateral, and contract violation scenarios. Amid deregulation, the impact of communication latency and changes in distribution participation are analyzed. The AVO-tuned T2FID+PD controller shows enhanced frequency regulation capabilities than its contemporaries as demonstrated through simulation studies on IEEE 39 Bus system. The suggested controller lowers settling time of frequency variation by 92.20%, 92.09%, and 92.19%; overshoot by 97.00%, 7.94%, and 96.08%; and undershoot by 89.68%, 93.37%, and 89.17% compared to several well-known studies in the literature.
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 71475-71493
Open AccessPerformance and Robustness Analysis of Optimal T2FID+PD Controller for Frequency Regulation in a Triple-Area Deregulated Power System
An enhanced type-2 fuzzy integral–derivative plus proportional-derivative (T2FID+PD) controller is suggested for mitigating frequency deviations in a triple-area hybrid power system (HPS). Optimal controller settings are computed using the African vulture optimizer (AVO). The thermal PS & distributed renewable generation (DRG) are interconnected in Area-1. This DRG unit comprises wind-turbine & solar-photovoltaic generation. The thermal & gas and thermal & nuclear facilities are interconnected in Area-2 and Area-3, respectively. The nonlinearities, including generation rate constraints (GRC), boiler dynamics (BD), and governor dead band (GDB), are also modeled. Moreover, the performance evaluation of an AVO-based tuned T2FID+PD control is compared with its contemporaries. Also, the effect of integrating electric vehicles is studied. Additionally, the developed controller's robustness to parameter variations in power systems is ascertained. Finally, the impact of deregulation is studied by simulating nominal, unilateral, and contract violation scenarios. Amid deregulation, the impact of communication latency and changes in distribution participation are analyzed. The AVO-tuned T2FID+PD controller shows enhanced frequency regulation capabilities than its contemporaries as demonstrated through simulation studies on IEEE 39 Bus system. The suggested controller lowers settling time of frequency variation by 92.20%, 92.09%, and 92.19%; overshoot by 97.00%, 7.94%, and 96.08%; and undershoot by 89.68%, 93.37%, and 89.17% compared to several well-known studies in the literature.