Fadzlyasraf Shaari
Research Subjects
Fadzlyasraf Shaari has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Asyraff Iqbal Anuar
Alfa Diagnostik Sdn Bhd (Co. No. 1033482-X), No. 13, Jalan Delta U6/18, Taman Perindustrian Sunway Subang, Seksyen U6, Shah Alam 40150, Malaysia
1 shared publication - Muhammad Nursyazwan Zamre
Special Protein Unit, Specialized Diagnostic Centre, Institute for Medical Research, National Institutes of Health, Jalan Pahang, Kuala Lumpur 50588, Malaysia
1 shared publication - Noor Hafizah Hassan
Special Protein Unit, Specialized Diagnostic Centre, Institute for Medical Research, National Institutes of Health, Jalan Pahang, Kuala Lumpur 50588, Malaysia
1 shared publication - Nurul Izzati Hamzan
Special Protein Unit, Specialized Diagnostic Centre, Institute for Medical Research, National Institutes of Health, Jalan Pahang, Kuala Lumpur 50588, Malaysia
1 shared publication - Siti Nurwani Ahmad Ridzuan
Special Protein Unit, Specialized Diagnostic Centre, Institute for Medical Research, National Institutes of Health, Jalan Pahang, Kuala Lumpur 50588, Malaysia
1 shared publication
Latest Publications
- Open Access
- 18 May 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (10) , 1532
Analytical Imprecision and Reference Change Values for Longitudinal Monitoring of NCD-Related Biochemical Analytes
Background: Internal quality control (IQC) data offers continuous insight into analytical performance under routine conditions. This study evaluated IQC practices and long-term analytical imprecision (CVa) across primary healthcare laboratories to derive analyte-specific reference change values (RCVs) for non-communicable disease (NCD) monitoring. Methods: A 22-month retrospective analysis of IQC data was conducted across 29 primary healthcare laboratories using 32 analytical units (Beckman Coulter AU480) in Malaysian primary healthcare. Six analytes were assessed: glucose, creatinine, total cholesterol, triglycerides, HDL cholesterol, and ALT. CVa was estimated using median and 90th percentile (P90) coefficients of variation across two concentration levels. RCVs were calculated at 95% probability (Z = 1.96) by integrating observed CVa with within-subject biological variation (CVi) from EFLM databases. Results: IQC testing was highly standardized (median: 20 measurements/month). Long-term data showed stable, concentration-dependent imprecision. Median CVa was lowest for glucose and lipids (1.7–1.9%) but higher for ALT (3.79%) and creatinine (3.52%) at Level 1. Derived RCV ranged from 14% (glucose) to 55.1% (triglycerides), with CVi being the dominant contributor to RCV magnitude for most analytes. Conclusions: Long-term routine IQC data provide an analytically realistic foundation for deriving RCV in primary healthcare by reflecting real-world performance. Applying these RCV supports evidence-based interpretation of serial results, enhancing NCD monitoring by distinguishing true physiological change from analytical and biological noise.
- 18 May 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (10) , 1532
Open AccessAnalytical Imprecision and Reference Change Values for Longitudinal Monitoring of NCD-Related Biochemical Analytes
Background: Internal quality control (IQC) data offers continuous insight into analytical performance under routine conditions. This study evaluated IQC practices and long-term analytical imprecision (CVa) across primary healthcare laboratories to derive analyte-specific reference change values (RCVs) for non-communicable disease (NCD) monitoring. Methods: A 22-month retrospective analysis of IQC data was conducted across 29 primary healthcare laboratories using 32 analytical units (Beckman Coulter AU480) in Malaysian primary healthcare. Six analytes were assessed: glucose, creatinine, total cholesterol, triglycerides, HDL cholesterol, and ALT. CVa was estimated using median and 90th percentile (P90) coefficients of variation across two concentration levels. RCVs were calculated at 95% probability (Z = 1.96) by integrating observed CVa with within-subject biological variation (CVi) from EFLM databases. Results: IQC testing was highly standardized (median: 20 measurements/month). Long-term data showed stable, concentration-dependent imprecision. Median CVa was lowest for glucose and lipids (1.7–1.9%) but higher for ALT (3.79%) and creatinine (3.52%) at Level 1. Derived RCV ranged from 14% (glucose) to 55.1% (triglycerides), with CVi being the dominant contributor to RCV magnitude for most analytes. Conclusions: Long-term routine IQC data provide an analytically realistic foundation for deriving RCV in primary healthcare by reflecting real-world performance. Applying these RCV supports evidence-based interpretation of serial results, enhancing NCD monitoring by distinguishing true physiological change from analytical and biological noise.