Filippo Bittoni
Filippo Bittoni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Filippo Bittoni has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Michele Battistoni
Department of Engineering, Università degli Studi di Perugia, 06125 Perugia, Italy
2 shared publications - Andrea Di Mascio
University of L'Aquila
1 shared publication Carlo Nazareno Grimaldi
1 shared publication- Federico Ricci
Federal-Mogul Powertrain Italy, Via Della Scienza 6/8, 41012 Carpi, Italy
1 shared publication - Francesca Dell’AGnello
BioCardioLab, Bioengineering Unit, Fondazione Monasterio, 54100 Massa, Italy
1 shared publication - Francesco Duronio
Dipartimento di Ingegneria Industriale e Dell’Informazione e di Economia, Università Degli Studi Dell’Aquila, Piazzale Ernesto Pontieri, Monteluco di Roio, 67100 L’Aquila, Italy
1 shared publication
Latest Publications
- Open Access
Comparison of Rigid-Wall Computational Fluid Dynamics and Flexible-Wall Fluid-Structure Interaction in Descending Thoracic Aorta Aneurysm
Currently, Computational Solid Mechanics (CSM) and Computational Fluid Dynamics (CFD) simulations are not enough to correctly estimate the different physical characteristics found in the human cardiovascular system. As an alternative to individual simulations, Fluid Structure Interaction (FSI) simulations can yield more accurate physical quantities. In this study a comparison between rigid-wall CFD of a thoracic aorta affected by an aneurysm and the FSI of the Descending Thoracic Aortic Aneurysm (DTAA) itself was performed. The 18-year-old patient-specific geometry of the aorta and its branches was based on the National Institutes of Health public database. A patient-specific pulsatile blood flow waveform and a pressure three-element Windkessel model were set for boundary conditions. Parameters such as wall pressure, velocity distribution, Wall Shear Stress (WSS), Time-averaged Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI), wall displacement and Von Mises Stress (VMS) were investigated. The research shown that blood flow in the aorta is strongly affected by the onset of the aneurysm, which causes recirculation and uneven flow within the aneurysmal bulge. The results highlight that rigid-wall CFD, which cannot capture wall deformation and aneurysm compliance, leads to an overestimation of velocity, WSS, and TAWSS by 15, 21, and respectively, compared to FSI during the systolic peak; furthermore, a key novelty is represented by the slight underestimation of pressure during the systolic peak, an aspect not previously detailed in the DTAA literature.Open AccessComparison of Rigid-Wall Computational Fluid Dynamics and Flexible-Wall Fluid-Structure Interaction in Descending Thoracic Aorta Aneurysm
Currently, Computational Solid Mechanics (CSM) and Computational Fluid Dynamics (CFD) simulations are not enough to correctly estimate the different physical characteristics found in the human cardiovascular system. As an alternative to individual simulations, Fluid Structure Interaction (FSI) simulations can yield more accurate physical quantities. In this study a comparison between rigid-wall CFD of a thoracic aorta affected by an aneurysm and the FSI of the Descending Thoracic Aortic Aneurysm (DTAA) itself was performed. The 18-year-old patient-specific geometry of the aorta and its branches was based on the National Institutes of Health public database. A patient-specific pulsatile blood flow waveform and a pressure three-element Windkessel model were set for boundary conditions. Parameters such as wall pressure, velocity distribution, Wall Shear Stress (WSS), Time-averaged Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI), wall displacement and Von Mises Stress (VMS) were investigated. The research shown that blood flow in the aorta is strongly affected by the onset of the aneurysm, which causes recirculation and uneven flow within the aneurysmal bulge. The results highlight that rigid-wall CFD, which cannot capture wall deformation and aneurysm compliance, leads to an overestimation of velocity, WSS, and TAWSS by 15, 21, and respectively, compared to FSI during the systolic peak; furthermore, a key novelty is represented by the slight underestimation of pressure during the systolic peak, an aspect not previously detailed in the DTAA literature. - Open Access
- 19 May 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 242
Experimental study on ultra-lean hydrogen combustion using a dedicated cold spark plug ignition system
- 19 May 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 242
Open AccessExperimental study on ultra-lean hydrogen combustion using a dedicated cold spark plug ignition system