VRVeronica Ruozzi

Veronica Ruozzi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Veronica Ruozzi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Catheter monitoring in intelligent endovascular navigation systems: interactive simulations and mixed reality for enhanced navigational awareness

    by Veronica Ruozzi, Giovanni Battista Regazzo, Maria Chiara Palumbo, Wim-Alexander Beckers, Mouloud Ourak, Xiu Zhang, Francesca Perico, Alessandro Caimi, Emmanuel Vander Poorten, Emiliano Votta

    Purpose: The aim is to develop and test a framework that integrates real-time catheter shape reconstruction, interactive simulations, and mixed reality visualization to enable accurate monitoring of catheter vessel interactions during endovascular navigation. Methods: A finite element model (FEM) of the venous pathway from the right femoral vein to the inferior vena cava was generated from computed tomography data and implemented into an interactive simulation. Catheter motion was imposed as boundary condition, and catheter vessel contact was modeled with a Lagrange multiplier formulation to compute vessel deformation. The framework was integrated and tested in vitro using a sensorized catheter with fiber Bragg grating and electromagnetic sensors to provide real-time 3D shape and location as it was advanced by a catheter driver through a silicone replica of the vascular anatomy. Upon registration, real-time sensor read-outs fed the simulation, and the updated catheter and vessel geometries were streamed to Hololens $$2^{\textrm{TM}}$$ 2 TM (HL2). The performance of the simulation and the accuracy of FEM-computed vessel wall displacement were validated vs. experimental ground truth obtained via stereo frames triangulation. Results: Complexity and extent of catheter vessel interaction affected FEM performance by increasing the computational cost. The simulated time exceeded the real temporal extent of the physical phenomenon by 12% during the initial navigation phase and by 45% when the catheter reached the most tortuous portion of the vessel. The HL2 rendering remained stable between 35 and 40 frames per second. Across these two phases, the median relative displacement error between FEM-computed vessel wall displacements and the ground truth remained below 1 mm and 2.33 mm, respectively. Conclusion: The study demonstrates the feasibility of integrating interactive biomechanical simulation with real-time sensor data to enable continuous monitoring of catheter vessel interactions, with mixed reality visualization serving as a user interface to support a more engaged and better-informed operator throughout the navigation.

  • Open Access

    Physics-Driven Sonification for Improving Multisensory Needle Guidance in Percutaneous Epicardial Access

    by Veronica Ruozzi, Sasan Matinfar, Pasquale Vergara, Alessandro Albanesi, Serena Dell'AVersana, Stefano Carugo, Gianluigi Buccoliero, Nassir Navab, Alberto Redaelli, Emiliano Votta

    Percutaneous epicardial access (PEA), performed on a beating heart under fluoroscopy, enables arrhythmia treatment. However, advancing a needle toward the thin, moving pericardium remains highly challenging and risky. To address this challenge, we present a novel physics-driven sonification method for Extended Reality (XR)-based multisensory navigation to enhance user perception regarding critically sensitive needle landing phase in PEA. Dynamic cardiac anatomy from 4DCTA was reconstructed and registered to a real-world coordinate system. Real-time needle tracking provided data of the needle tip relative to moving cardiac structures, driving the audio-visual feedback module. The visual display presents navigational cues and dynamic cardiac structures, whereas the auditory display encodes physiological cardiac states into a rigorous mapping through a multilayered physical membrane. To prove this novel concept, a phantom study was conducted with twelve cardiologists performing needle insertions under visual-only and multisensory feedback. Results show that the proposed multisensory method improved the navigation safety (χ2 = 11.30, p < 0.01), reducing myocardial contact (3.64% vs. 7.27%) and increasing correct access (90.91% vs. 52.73%). Needle placement accuracy improved, with closer membrane proximity (Cliff’s δ = 0.19) and reduced variability (Fligner p < 0.05). Execution time remained comparable, but time–accuracy correlations differed significantly between modalities (Fisher’s p < 0.01). NASA-TLX showed lower cognitive load with multisensory guidance (t = −4.02, p < 0.01). In conclusion, the multisensory system is associated with improved spatiotemporal awareness and suggests potential benefits for surgical navigation, while indicating reduced cognitive load. These findings demonstrate the feasibility of physics-driven sonification for supporting user-centered interaction and motivate further validation in realistic and clinical environments.