Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marco Cen-Puc has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Heat Treatment on Electrical Insulation of Strain Sensors for Aluminum Cast Parts

    by Marco Cen-Puc, Tim de Rijk, Dirk Lehmhus, Walter Lang

    This work presents the effect of thermal treatment on the electrical insulation of strain sensors on aluminum substrates. The sensors are meant to be embedded into cast aluminum parts, which are heat-treated for strengthening via precipitation hardening. For sensor manufacturing, thick film materials are used for the electrical insulation and its connection tracks, whereas sensing platinum structures are produced by sputtering. The effectiveness of different insulation thicknesses was tested for a treatment regime of 7 h at 535 °C, which matches solution heat treatment conditions as the most demanding part of the precipitation hardening process. The results showed that insulation is partially lost after treatment, and six consecutive insulating layers are required to produce an insulation capable of withstanding an extended heat treatment.

  • Open Access

    Integrated Flexible Polyimide Sensor for Monitoring Compressive Force in Sealings

    by Tim M. de Rijk, M. Cen-Puc, Y. Mirzaei, P. Schneider, U. Giese, W. Lang

    This article is an extension of the IEEE Sensor Conference 2022 paper and presents a study on the fabrication and integration of pressure sensors into rubber sealings. The sensors were used to continuously measure the applied pressure and monitor the sealing’s condition. The sensors are made using a single layer Polyimide-based piezoresistive material with gold interdigital electrodes. The working principle is the material conductivity change due to the rearrangement of conductive carbon nanotubes within the polymer caused by the applied pressure. The sensors were integrated into rubber sealings during their vulcanization process and it was found that higher vulcanization pressures suggest better integration as the air gap between the sensors and sealing is reduced. The sensor’s performance is characterized by measurements of its resistance change due to the pressure response. The study shows that sensors with a 50 μm interdigital electrode distance have a linear sensitivity up to a pressure of 55N, while sensors with a larger (200 μm) interdigital electrode distance have a lower linear region up to almost 10N, but higher sensitivity. The thickness of the piezoresistive layer also affects the sensors sensitivity, with thinner layers showing increased sensitivity but with a limited effective pressure region. The study shows that the relaxation phenomena of the rubber sealing can be measured with the sensor. Overall, the integration of sensors into sealings provides a real-time condition monitoring system that can detect faults and reduce the risk of environmental damage caused by fluid leakage, damage, and corrosion.


  • Strain Microsensors Based on Carbon Nanotube/Polyimide Thin Films

    by Marco Cen-Puc, Tim de Rijk, Andreas Schander, Minerva Vargas Gleason, Walter Lang

    The work shows the process for the fabrication of strain sensors using a 5 µm thick polyimide film loaded with 3 % weight carbon nanotubes as piezoresistive material. The sensors were produced using standard photolithography techniques, which allowed a reliable structuring of meanders with a linewidth of 50 µm and a line aspect ratio of 1:10. The thin film sensors were tested under tensile 1% strain for their characterization. The gauge factor of the produced sensors was k ~ 30. The sensors exhibited a slight drift of their electrical resistance after repeated tensile cycles. It was also noticed that their electrical resistance is influenced by the temperature with a negative dependence. These results help to establish the possibilities of integrating polymer nanocomposites for the development of strain sensors.


  • Online Cure Monitoring of Carbon Nanotube/Polyimide Films

    by Marco Cen-Puc, Minerva G. Vargas Gleason, Andreas Schander, Walter Lang

    The work presents a method for online cure monitoring of polyimide nanocomposite films by measuring their electrical resistance. The polymer is mixed with 3% weight carbon nanotubes, and interdigital gold electrodes are structured on a silicon wafer to measure the electrical resistance. A series of drops in the electrical resistance was observed for each temperature step during the curing process. The first and most significant resistance drop occurred at 120 °C. This sudden change was attributed to the evaporation of the solvent since a weight change in the film was observed. A numerical model which computes the number of connected carbon nanotubes with respect to different solvent content also supports the theory of solvent evaporation. The presented method provides a tool to control the curing process of polymers. Moreover, the material could be also used for the fabrication of film polymer-based thermistors.

  • Carbon Nanotubes/Polymer Films for Microsensors Applications

    by Marco Cen-Puc, Tim de Rijk, Minerva Vargas Gleason, Walter Lang

    This work presents a simple fabrication method for piezoresistive polymer films with two polymers commonly used in microelectronics: polyimide, and polydimethylsiloxane. The films were produced by direct mixing of carbon nanotubes in the polymer for spin coating on a silicon wafer. The proposed method produces a homogeneous material, which requires less processing time and complexity compared to the conventional solvent/ultrasonic method. The produced films exhibited piezoresistive response under strain tests and thermoresistive properties, indicating their potential use for further fabrication of piezoresistive and thermoresistive microsensors.


  • Open Access

    An Assessment of Surface Treatments for Adhesion of Polyimide Thin Films

    by Marco Cen-Puc, Andreas Schander, Minerva G. Vargas Gleason, Walter Lang

    Polyimide films are currently of great interest for the development of flexible electronics and sensors. In order to ensure a proper integration with other materials and PI itself, some sort of surface modification is required. In this work, microwave oxygen plasma, reactive ion etching oxygen plasma, combination of KOH and HCl solutions, and polyethylenimine solution were used as surface treatments of PI films. Treatments were compared to find the best method to promote the adhesion between two polyimide films. The first selection of the treatment conditions for each method was based on changes in the contact angle with deionized water. Afterward, further qualitative (scratch test) and a quantitative adhesion assessment (peel test) were performed. Both scratch test and peel strength indicated that oxygen plasma treatment using reactive ion etching equipment is the most promising approach for promoting the adhesion between polyimide films.


  • Cyclic Thermoresistivity of Freestanding and Polymer Embedded Carbon Nanotube Yarns

    by Abraham Balam, Marco Cen-Puc, Omar Rodríguez-Uicab, Jandro L. Abot, Francis Avilés

    Carbon nanotube yarns (CNTYs) are hierarchical fibers with outstanding electrical properties, and understating the temperature‐dependence of their electrical resistance (thermoresistivity) is essential for sensing applications and development of self‐sensing polymer composites. The cyclic thermoresistive response of individual CNTYs and the effect of embedding the yarn into a polymer are experimentally investigated herein. The effect of confining the CNTY by a thermosetting polymer is addressed by studying the thermoresistive response of CNTY/vinyl ester single‐fiber composites. Heating–cooling cycles ranging from 25 (room temperature [RT]) to 100 °C and 25 to −30 °C are applied to individual CNTYs and to CNTYs embedded into a vinyl ester polymer, while their electrical resistance is simultaneously recorded. Both the CNTY and its single‐fiber composite show a negative dependence of electrical resistance with temperature. For both temperature ranges (above and below RT), the average temperature coefficient of resistance found for individual CNTYs is ≈−9.5 × 10−4 K−1, and its magnitude decreases about ≈30% when the yarn is embedded into the vinyl ester polymer. The hysteresis rendered by the different heating and cooling pathways is small for individual CNTYs, and largely increases when the CNTY is embedded into the polymer.


  • Using RFID to Monitor the Curing of Aramid Fiber Reinforced Polymers

    by Marius Veigt, Marco Cen, Elisabeth Hardi, Walter Lang, Michael Freitag


  • Influence of polymer matrix on the sensing capabilities of carbon nanotube polymeric thermistors

    by A Balam, M Cen-Puc, A May-Pat, J L Abot, F Avilés

    The thermoresistive response of multiwall carbon nanotube (MWCNT)/polymer composites is investigated, focusing on the role of the polymer matrix. This is achieved by experimentally investigating the cyclic thermoresistive response of MWCNT composites with three types of thermo-mechanically dissimilar matrices, viz. a thermosetting (vinyl ester) resin, an engineering thermoplastic (polysulfone), and a commodity thermoplastic (polypropylene). Thermoresistive characterization covered cyclic heating and cooling below (25 °C to −30 °C) and above (25 °C to 100 °C) room temperature. A strong influence of the polymer matrix was found, including different linearity in the response, thermoresistive sensitivity, and hysteresis, depending on the thermo-mechanical properties of the polymer. Polypropylene nanocomposites showed the highest sensitivity and overall lower hysteretic parameters, ascribed to its high coefficient of thermal expansion, low elastic modulus and low glass transition temperature. Polypropylene and polysulfone nanocomposites showed high fidelity in their implementation as thermistors, with readings close to those of a commercial thermistor.