Chenyue Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chenyue Wang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Liujiang Zhang
The Institute for Advanced Studies, Wuhan University, Wuhan 430072, People's Republic of China
3 shared publications- Xingyu Gao
Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201204, China
3 shared publications - Zhenhuang Su
Shanghai Synchrotron Radiation Facility (SSRF) Shanghai Advanced Research Institute Chinese Academy of Sciences Shanghai China
3 shared publications Bingchen He
Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201204, People's Republic of China
2 shared publicationsJihao Zhang
Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, People's Republic of China
2 shared publicationsMeirong Fu
Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201204, People's Republic of China
2 shared publications
Latest Publications
- Open Access
- 21 May 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (4) , 1043-1054
GIWAXS using microbeam applied in halide perovskite films for high spectral resolution and mapping capability
Synchrotron-based grazing-incidence wide-angle X-ray scattering (GIWAXS) has become an essential tool for investigating halide perovskite film microstructures. Nevertheless, GIWAXS employing 100 µm X-ray beams inevitably suffers from footprint effects manifesting as diffraction peak broadening and spectral distortions. Herein, we demonstrate that microbeam GIWAXS (µ-GIWAXS) effectively mitigates these footprint effects, achieving enhanced spectral resolution and accuracy. By systematically tuning the grazing incidence angle, we quantitatively illustrated how the footprint length contributes to diffraction peak broadening in µ-GIWAXS. In addition, we optimize µ-GIWAXS data acquisition through beam-direction-perpendicular fly scanning, which improves data quality while preserving resolution and minimizing radiation damage at individual spots. Through extended exposure experiments, the effect of µ-GIWAXS microbeam irradiation on the structural stability of perovskite films was systematically evaluated. Furthermore, µ-GIWAXS enables spatial mapping of perovskite film microstructural characteristics including crystallinity, preferential crystal orientation, PbI 2 concentration and lattice strain – critical information for addressing inhomogeneity challenges in large-area perovskite devices. Given the growing demand in scalable perovskite optoelectronic applications, µ-GIWAXS warrants increased attention due to its dual advantages of superior spectral resolution and spatially resolved analysis capabilities.
- 21 May 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (4) , 1043-1054
Open AccessGIWAXS using microbeam applied in halide perovskite films for high spectral resolution and mapping capability
Synchrotron-based grazing-incidence wide-angle X-ray scattering (GIWAXS) has become an essential tool for investigating halide perovskite film microstructures. Nevertheless, GIWAXS employing 100 µm X-ray beams inevitably suffers from footprint effects manifesting as diffraction peak broadening and spectral distortions. Herein, we demonstrate that microbeam GIWAXS (µ-GIWAXS) effectively mitigates these footprint effects, achieving enhanced spectral resolution and accuracy. By systematically tuning the grazing incidence angle, we quantitatively illustrated how the footprint length contributes to diffraction peak broadening in µ-GIWAXS. In addition, we optimize µ-GIWAXS data acquisition through beam-direction-perpendicular fly scanning, which improves data quality while preserving resolution and minimizing radiation damage at individual spots. Through extended exposure experiments, the effect of µ-GIWAXS microbeam irradiation on the structural stability of perovskite films was systematically evaluated. Furthermore, µ-GIWAXS enables spatial mapping of perovskite film microstructural characteristics including crystallinity, preferential crystal orientation, PbI 2 concentration and lattice strain – critical information for addressing inhomogeneity challenges in large-area perovskite devices. Given the growing demand in scalable perovskite optoelectronic applications, µ-GIWAXS warrants increased attention due to its dual advantages of superior spectral resolution and spatially resolved analysis capabilities.
- Open Access
- 31 March 2026
- Published by Scilight Press Pty Ltd in Advanced Characterization
- Vol. 1 (1) , 12-21
Probing Buried Interfaces and Phase Gradients in MAPbI3 Films via Combined Back- and Surface-Incidence GIXRD
Interfaces between the perovskite absorber and charge-transport layers play a critical role in determining the performance of planar perovskite solar cells (PSCs). However, the lack of non-destructive techniques capable of directly probing the microstructure of buried interfaces beneath perovskite films has significantly hindered a comprehensive understanding of their interfacial properties. Here, we employ flexible substrates to enable synchrotron-based grazing-incidence X-ray diffraction (GIXRD) measurements from the backside of the substrate, allowing direct investigation of buried interfaces. By combining back- and surface-incidence GIXRD, we construct a depth-resolved phase diagram spanning from the film surface to the buried interface in one-step deposited MAPbI3 films. The film surface is dominated by a thin tetragonal perovskite layer, whereas a cubic phase gradually emerges with increasing depth, leading to phase coexistence within the film interior. Closer to the buried interface, the cubic phase progressively dominates, with the tetragonal phase completely disappearing at the interface. Meanwhile, high-resolution synchrotron X-ray diffraction measurements of MAPbI3 powders at variable temperatures reveal that cubic and tetragonal phases can coexist, with their relative fractions strongly dependent on thermal history, despite the thermodynamic preference for the tetragonal phase at room temperature. The observed depth-dependent phase distribution in MAPbI3 films is therefore attributed to an incomplete cubic-to-tetragonal phase transition during cooling after annealing, which becomes increasingly suppressed with depth due to substrate confinement. These findings provide new insights into the structure – performance relationship of one-step deposited MAPbI3-based PSCs and demonstrate that back-incidence GIXRD is a powerful and broadly applicable tool for probing buried interfaces in thin-film systems.
- 31 March 2026
- Published by Scilight Press Pty Ltd in Advanced Characterization
- Vol. 1 (1) , 12-21
Open AccessProbing Buried Interfaces and Phase Gradients in MAPbI3 Films via Combined Back- and Surface-Incidence GIXRD
Interfaces between the perovskite absorber and charge-transport layers play a critical role in determining the performance of planar perovskite solar cells (PSCs). However, the lack of non-destructive techniques capable of directly probing the microstructure of buried interfaces beneath perovskite films has significantly hindered a comprehensive understanding of their interfacial properties. Here, we employ flexible substrates to enable synchrotron-based grazing-incidence X-ray diffraction (GIXRD) measurements from the backside of the substrate, allowing direct investigation of buried interfaces. By combining back- and surface-incidence GIXRD, we construct a depth-resolved phase diagram spanning from the film surface to the buried interface in one-step deposited MAPbI3 films. The film surface is dominated by a thin tetragonal perovskite layer, whereas a cubic phase gradually emerges with increasing depth, leading to phase coexistence within the film interior. Closer to the buried interface, the cubic phase progressively dominates, with the tetragonal phase completely disappearing at the interface. Meanwhile, high-resolution synchrotron X-ray diffraction measurements of MAPbI3 powders at variable temperatures reveal that cubic and tetragonal phases can coexist, with their relative fractions strongly dependent on thermal history, despite the thermodynamic preference for the tetragonal phase at room temperature. The observed depth-dependent phase distribution in MAPbI3 films is therefore attributed to an incomplete cubic-to-tetragonal phase transition during cooling after annealing, which becomes increasingly suppressed with depth due to substrate confinement. These findings provide new insights into the structure – performance relationship of one-step deposited MAPbI3-based PSCs and demonstrate that back-incidence GIXRD is a powerful and broadly applicable tool for probing buried interfaces in thin-film systems.