YLYi Li

Yi Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yi Li has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Magneto-Hyperdynamic Energetic Liquid Metals

    by Yi Li, Yifei Li, Yongyu Lu, Yinxiang Meng, Naiyu Guan, Jingran Wang, Jixin Chu, Zhongzheng Pei, Ying Chang, Chi Zhang, et al.

    Liquid metals (LMs) are fluidic and conductive, but their high thermal diffusivity and chemical passivity have long excluded them from energetic potentials. Here we report a magneto-hyperdynamic composite (MH-ELM) that breaks this barrier. Fabricated by simple stirring of a Ga-In alloy with in-situ generated Ga₂O₃, boron and NdFeB particles, the MH-ELM exploits cooperative material system: a percolating oxide network that enables efficient induction heating, a previously unrecognized B-Ga₂O₃ exothermic reaction that serves as an internal chemical amplifier, and the frequency-controlled skin effect that tunes reaction initiation and propagation. Under an alternating magnetic field, the MH-ELM combusts violently and expands to over two times its original volume, reaching 1275 °C within 1 s. This output exceeds the highest recorded temperature for liquid-metal systems by one order of magnitude and accelerates heating rates by five-fold. Our work overturns the dogma that LMs are inherently inert, and establishes a design principle: metastable, soft composites can store chemical energy and release it violently on remote command. This concept may find use in rapid actuation, field repair and deployable systems, and more broadly suggests that deliberate metastability offers a route to extreme performance in otherwise passive materials.

  • Open Access

    A freestanding submicron electrocorticography electrode array

    by Chuchao Wang, Zehan Liu, Wuhao Zhang, Ran Yang, Yi Li, Zhengfei Wang, Dianwu Chu, Xing Zhou, Weiqiang Hong, Shengzhao Wang, et al.

    Electrocorticography electrode arrays (EEAs) are key brain-computer interfaces. To be freestanding, which lays the foundation of fabrication and implantation, EEAs need to maintain sufficient rigidity. However, to form seamless and damage-free contact on the cerebral cortex, EEAs should be super-flexible, raising a seemingly unsolvable dilemma. Here, inspired by dragonfly wings, we present a freestanding submicron EEA (fs-EEA) that combines rigidity and flexibility, which are typically mutually exclusive characteristics. A wing vein-like frame is introduced to enable the freestanding capability, while the wing membrane-like functional region of fs-EEA is reduced to 850-nm-thickness that boosts its softness. This fs-EEA ensures excellent cortical conformality and biocompatibility on male epileptic rat models, improves electrocorticographic amplitude and signal-to-noise ratio. Our vein-membrane hybrid structure strategy thus resolves the inherent contradiction of EEAs, and has the potential to support advances in brain science and related fields.

  • A cyclo-acoustofluidic-separator for solution exchange with minimized concentration dilution

    by Chao Pan, Yufeng Wu, Xin He, Jingran Wang, Zeshi Yang, Yi Li, Mengxi Wu, Junshan Liu

    Acoustofluidic technology shows tremendous application potential in solution exchange due to its miniaturization, biocompatibility, and label-free property. However, the introduction of large volumes of sheath fluid causes severe sample dilution, imposing limitations in certain applications, such as continuous plasma exchange. To address the dilution issue caused by sheath fluid in acoustofluidic technology, this paper proposes a cyclo-acoustofluidic-separator, inspired by the structure of a cyclotron, to achieve iso-concentration solution exchange via multi-stage acoustic separation. The system combines acoustofluidic manipulation and passive hydrodynamic mechanism in a series of whirled microfluidic channel around standing surface acoustic wave fields, achieving particle transfer to the new medium with concentrations equivalent to 90.7% of the initial sample solution. Furthermore, the system achieves a particle sample throughput of 10 μl/min. It is expected to be able to process 1.5–2.5 ml blood volume within approximately 2–3 h, meeting the demands for plasma exchange of mice. Our system offers a novel solution to the dilution challenge of the acoustofluidic technology; thus, it is promising to provide more stable and reliable technical support for precise plasma exchange studies in small animal models and the potential development of specialized plasma exchange instruments for infants.

  • Nanocrack Encoded Electronic Skin for Vectorial Strain Sensing

    by Xinran Yan, Yuhang Yang, Xuan Li, Chuchao Wang, Pan Li, Jixin Chu, Weiyi Liu, Yifei Li, Jiaxuan Zhang, Junwei Wang, et al.

    Human skin perceives both the magnitude and direction of mechanical stimuli, an essential capability for dexterous interaction yet fully unrealized in humanoid robotics. Here we introduce a metallic nanocrack‐based electronic skin (Crack‐eSkin), a strain vector perceptron that encodes the complete strain vector through the algorithmic geometry of nanocracks in the 50 nm thick gold film. When mechanically stretched, orthogonal cracks open differentially depending on orientation, producing distinct signals that simultaneously encode both strain magnitude and direction as a two‐dimensional resistive fingerprint. This mechanism transforms mechanical stretch into an ultra‐sensitive (gauge factor: 3609) material‐level response that preserves both parameters at their source. Feeding encoded signal sequences into the developed geometry‐aware multitask temporal network (RMT‐Net) enables the joint prediction of strain magnitude and loading angle, achieving R 2 values of 0.982 for strain and 0.985 for angle. Installed onto an artificial face model, the Crack‐eSkin can quantitatively resolve sequential strain vectors of 2.60% at 87.4°, 1.84% at 7.7°, and 3.20% at 45.2° that human subjects could only describe qualitatively, paving the way for next‐generation robotic systems with human‐like or superior mechanosensation.

  • A pressure-tolerant, miniature ocean-sensing tag with acoustic telemetry for real-time CTD monitoring

    by Shao-Hao Lu, Jun Lu, Yi Li, Minsu Park, Jaeyoung Yoo, Aljon Salalila, Zhiqun Daniel Deng, Xueju Sophie Wang

    Real-time ocean monitoring enables instantaneous oceanographic analysis and supports maritime operations. However, conventional sensors require metallic housings to withstand high hydrostatic pressure, increasing their weight and power demand. Soft electronics offer a promising alternative, but their functionality and commonly used electromagnetic communication are ineffective underwater. Here, we present a pressure-tolerant, miniaturized ocean-sensing tag that seamlessly integrates soft conductivity, temperature, and depth (CTD) sensors with acoustic transducers for in situ monitoring and underwater data transmission. Measuring 17 mm by 20 mm by 7.5 mm and weighing 4.90 g, the tag maintains reliable performance under hydrostatic pressures of up to 15 MPa, corresponding to a depth of approximately 1,500 m, and achieves underwater transmission ranges of up to 492.7 m. Field testing in the Salish Sea demonstrates wireless, real-time CTD monitoring with measurement accuracy comparable to commercial sensors and reliable acoustic telemetry (87.34% detection efficiency and 100% accuracy over evaluated transmission distances). This ocean sensing platform enables energy-efficient deployment on diverse platforms and significantly advances next-generation ocean observation and deep-sea exploration.

  • Open Access

    Nano-thick freestanding and reusable epidermal electronics via edge-supporting strategy

    by Zehan Liu, Shengzhao Wang, Yina He, Chuchao Wang, Qihong Wu, Ran Yang, Xihan Wang, Weifeng Zhang, Weiqiang Hong, Yuan Gao, et al.

    Nano-thick epidermal electronics have extraordinary lightweight and conformability characteristics, thus enable high-quality signal acquisition and imperceptible wearing experience. However, reducing the device thickness to nanoscale makes the rigidity extremely low thus the device curls spontaneously, imposing unprecedented challenges to the device fabrication, handling and recycling. To resolve the dilemma of epidermal electronics, we propose an edge-supporting strategy that maintains the benefits of nano thickness, meanwhile obtains practicality and reusability via reinforced edge scaffold. The nano-thick (~500 nm thick) core area of the device provides perfect conformal, firm, and burdenless contact with human skin. On the other hand, the edge scaffold (~5 μm thick) plays an important role in protecting internal fragile film from external forces and providing rigid support during handling and recycling. In addition, the edge scaffold enables spontaneous release of nano-thick electronics from the substrate in water, getting rid of the use of sacrificial layers and etchants. We demonstrate the use of the edge-supporting strategy to develop a physiological electrode with low impedance less than 3.6 kΩ at 1 kHz, a resistance-type temperature sensor with fast response time less than 0.5 ms and a nanoengineering-based pressure sensor with high sensitivity of 62.9 kPa−1. Our work provides an effective method to handle and release nano-thick electronics without using external stamps, thereby enabling truly practical applications of ultrathin flexible electronics in the fields of wearable technology, healthcare and so on.

  • Open Access

    Four-dimensional reconfigurable vascular tunneling machine of spatially programmed liquid crystal elastomers

    by Yi Li, Yuan Gao, Yifei Li, Naiyu Guan, Zizheng Wang, Yongyu Lu, Weiqiang Hong, Chuchao Wang, Zeshi Yang, Ran Yang, et al.

    Thrombosis in tortuous vessels causes blockages and pathological conditions. Current thrombolytics are inefficient, and mechanical thrombectomies lack adaptability, hindering thrombus clearance in complex geometries. Here, we propose a 4D reconfigurable vascular tunneling machine (VTM) capable of synchronous rotation and elongation, mimicking teredo locomotion. The VTM operates via the reversible nematic-to-isotropic phase transition of liquid crystal elastomers, triggered by the reorientation of liquid crystal mesogens during a coupled contraction-torsion motion. Functionalized with magnetic liquid metals, the VTM achieves remote reconfiguration within 20 s via induction heating, with a temperature rise of only 1.1 °C and uniform heat dissipation. This rapid and safe thermal response facilitates the adaptive locomotion of the VTM within a cerebral artery model. Comprehensive biocompatibility evaluation confirms that the VTM exhibits no cytotoxicity and good hemocompatibility, and the VTM achieves the disruption of thrombus simulants across a stiffness range of 1 kPa to 1 MPa and sample retrieval up to 7.13 mm³. These demonstrations establish the VTM as a promising proof-of-concept platform, highlighting the potential for future development toward thrombus interventions and for operation as an adaptive soft robot in constrained environments.