Yang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yang Li has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jun Fu
School of Integrated Circuits, Tsinghua University, Beijing, China
2 shared publications - Tian-Ling Ren
School of Integrated Circuits & Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China
2 shared publications - Bing-Zhou Chen
College of Information and Electrical Engineering, China Agricultural University, Beijing 100083, P. R. China
1 shared publication Ding Li
Tsinghua University
1 shared publicationGuofang Yu
College of Computer Science and Technology, National University of Defense Technology, Changsha, China
1 shared publication- Hai-Ying Zheng
College of Information and Electrical Engineering, China Agricultural University, Beijing 100083, P. R. China
1 shared publication
Latest Publications
- 24 August 2026
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 11 (9) , 8168-8176
A Wearable Open-Domain Bioimpedance Sensor for Noninvasive Assessment of Deep Abdominal Fat Distribution
Abnormal accumulation of visceral adipose tissue (VAT) is a major risk factor for metabolic syndrome and cardiovascular disease. However, existing methods remain limited in their ability to provide noninvasive, dynamic, and quantitative assessment of local fat distribution. In this study, we propose a wearable open-domain bioimpedance sensor for abdominal fat distribution assessment. The system integrates a multichannel bioimpedance acquisition platform with a flexible electrode array featuring a triangular-beam architecture. The measured signals were analyzed using three-dimensional difference open-domain reconstruction, from which a deep-region conductivity feature, σ̅d, was extracted to indirectly characterize deep fat distribution. In an exploratory study involving 10 volunteers, the EIT-derived feature σ̅d exhibited a negative association with the VAT estimates reported by a commercial body-composition analyzer, although the relationship varied between the female and male groups. These preliminary observations support the feasibility of extracting deep-fat-related electrical information from body-surface measurements.
- 24 August 2026
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 11 (9) , 8168-8176
A Wearable Open-Domain Bioimpedance Sensor for Noninvasive Assessment of Deep Abdominal Fat Distribution
Abnormal accumulation of visceral adipose tissue (VAT) is a major risk factor for metabolic syndrome and cardiovascular disease. However, existing methods remain limited in their ability to provide noninvasive, dynamic, and quantitative assessment of local fat distribution. In this study, we propose a wearable open-domain bioimpedance sensor for abdominal fat distribution assessment. The system integrates a multichannel bioimpedance acquisition platform with a flexible electrode array featuring a triangular-beam architecture. The measured signals were analyzed using three-dimensional difference open-domain reconstruction, from which a deep-region conductivity feature, σ̅d, was extracted to indirectly characterize deep fat distribution. In an exploratory study involving 10 volunteers, the EIT-derived feature σ̅d exhibited a negative association with the VAT estimates reported by a commercial body-composition analyzer, although the relationship varied between the female and male groups. These preliminary observations support the feasibility of extracting deep-fat-related electrical information from body-surface measurements.
- 25 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
AlN and LGS Surface Acoustic Wave Resonators for Passive Wireless High-Temperature Sensing
Surface acoustic wave (SAW) resonators demonstrate significant potential in passive wireless high-temperature sensing applications. However, their performance and reliability under extreme temperatures are fundamentally constrained by the thermal stability of the piezoelectric substrate. This paper presents the design, characterization, and sensing device of single-port SAW resonators based on aluminum nitride (AlN) and langasite (LGS) substrates. High-temperature experiments were conducted in air atmosphere from 25°C to 750°C using a muffle furnace, enabling real-time monitoring of the resonant frequency evolution. The AlN-based resonator, benefiting from a high phase velocity, achieved a resonant frequency of 2.1 GHz and exhibited superior temperature sensitivity, making it advantageous for developing compact, highly sensitive wireless sensors. However, it showed irreversible sensing characteristic drift during thermal cycling, limiting its stable operating temperature to below 600°C. In contrast, the LGS-based resonator maintains exceptional stability and repeatability over multiple thermal cycles up to 750°C. Furthermore, we successfully demonstrate a passive wireless sensing system using the LGS resonator, which enables precise temperature detection by monitoring shifts in the resonant frequency.
- 25 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
AlN and LGS Surface Acoustic Wave Resonators for Passive Wireless High-Temperature Sensing
Surface acoustic wave (SAW) resonators demonstrate significant potential in passive wireless high-temperature sensing applications. However, their performance and reliability under extreme temperatures are fundamentally constrained by the thermal stability of the piezoelectric substrate. This paper presents the design, characterization, and sensing device of single-port SAW resonators based on aluminum nitride (AlN) and langasite (LGS) substrates. High-temperature experiments were conducted in air atmosphere from 25°C to 750°C using a muffle furnace, enabling real-time monitoring of the resonant frequency evolution. The AlN-based resonator, benefiting from a high phase velocity, achieved a resonant frequency of 2.1 GHz and exhibited superior temperature sensitivity, making it advantageous for developing compact, highly sensitive wireless sensors. However, it showed irreversible sensing characteristic drift during thermal cycling, limiting its stable operating temperature to below 600°C. In contrast, the LGS-based resonator maintains exceptional stability and repeatability over multiple thermal cycles up to 750°C. Furthermore, we successfully demonstrate a passive wireless sensing system using the LGS resonator, which enables precise temperature detection by monitoring shifts in the resonant frequency.
- 25 May 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Circuits, Systems and Computers
An Electrical Impedance Tomography Method under Noise
The inverse problem solution in electrical impedance tomography (EIT) is sensitive to measurement noise. Due to modeling errors and contact impedance, EIT measurement data are often contaminated by noise, which affects the accuracy of image reconstruction. This study introduces a novel denoising method combining discrete wavelet transform (DWT) with a denoising autoencoder (DAE) to effectively address measurement noise. The DWT–DAE method was systematically evaluated on various EIT electrode pairs data, including simulated data with different SNR levels (20–60[ ]dB), water tank measurement data and KIT4 public dataset. Results show that the DWT–DAE method significantly reduces noise in EIT measurement data, improving the SNR from approximately 20–30[ ]dB to over 55[ ]dB, thereby enhancing the quality of reconstructed images. To validate the practical efficacy of our approach, we applied it to the challenging case of intact maize ears. The DWT–DAE method was used to denoise the EIT measurements, followed by image reconstruction using the Convex–Concave Procedure-based Block Sparse Bayesian Learning Algorithm (CCPBSBL). Results indicate that this integrated methodology substantially enhances the accuracy of reconstructed conductivity distributions in maize ears, demonstrating its practical value for agricultural applications.
- 25 May 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Circuits, Systems and Computers
An Electrical Impedance Tomography Method under Noise
The inverse problem solution in electrical impedance tomography (EIT) is sensitive to measurement noise. Due to modeling errors and contact impedance, EIT measurement data are often contaminated by noise, which affects the accuracy of image reconstruction. This study introduces a novel denoising method combining discrete wavelet transform (DWT) with a denoising autoencoder (DAE) to effectively address measurement noise. The DWT–DAE method was systematically evaluated on various EIT electrode pairs data, including simulated data with different SNR levels (20–60[ ]dB), water tank measurement data and KIT4 public dataset. Results show that the DWT–DAE method significantly reduces noise in EIT measurement data, improving the SNR from approximately 20–30[ ]dB to over 55[ ]dB, thereby enhancing the quality of reconstructed images. To validate the practical efficacy of our approach, we applied it to the challenging case of intact maize ears. The DWT–DAE method was used to denoise the EIT measurements, followed by image reconstruction using the Convex–Concave Procedure-based Block Sparse Bayesian Learning Algorithm (CCPBSBL). Results indicate that this integrated methodology substantially enhances the accuracy of reconstructed conductivity distributions in maize ears, demonstrating its practical value for agricultural applications.