FCFatima Cherdouh
Fatima Cherdouh
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Fatima Cherdouh has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Arne K. Te Nijenhuis
NLR—Royal Netherlands Aerospace Centre, 1059 CM Amsterdam, The Netherlands
1 shared publication - Esli Trejo Peimbert
Liebherr-Aerospace Toulouse SAS, 31016 Toulouse, France
1 shared publication - Guilhem Delpu
Liebherr-Aerospace Toulouse SAS, 31016 Toulouse, France
1 shared publication - Guillaume Galzin
Liebherr-Aerospace Toulouse SAS, 31016 Toulouse, France
1 shared publication - Henk Jan van Gerner
NLR—Royal Netherlands Aerospace Centre, 1059 CM Amsterdam, The Netherlands
1 shared publication - Johannes van Es
NLR—Royal Netherlands Aerospace Centre, 1059 CM Amsterdam, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 26 May 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 133 (1) , 173
Modeling Comparison of a Two-Phase Mechanically Pumped Loop with a Conventional Ethylene Glycol Water Single-Phase Mechanically Pumped Loop for Fuel-Cell Cooling in TheMa4HERA
The fuel-cell (FC) technology currently being considered to reduce aircraft greenhouse gas emissions may require large and heavy cooling systems. The paper introduces the two-phase (2) Mechanically Pumped Loop (MPL) for FC cooling and compares it numerically with the conventional Ethylene Glycol Water (EGW) single-phase (1) cooling system for a MW heat-dissipation load. Considering an operating temperature of 90 °C, the system mass of the 2 MPL with and without an accumulator is found to be, respectively, 33% and 64% lower than the EGW system. Furthermore, the frontal area of the ram air heat exchanger (HX) was found to be 19% smaller, reducing ram air drag. An increase of the operating temperature to 130 °C was found to reduce the cooling system mass by 21% for the 1 MPL, and 22 to 29% for the 2 MPL. The frontal area of the ram air HX was found to be reduced by 44% and 40% for the 1 and 2 MPL, respectively. These results demonstrate the considerable performance gain of the 2 MPL over the 1 MPL for FC cooling, and the benefits of increasing the operating temperature for the cooling system.- 26 May 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 133 (1) , 173
Open AccessModeling Comparison of a Two-Phase Mechanically Pumped Loop with a Conventional Ethylene Glycol Water Single-Phase Mechanically Pumped Loop for Fuel-Cell Cooling in TheMa4HERA
The fuel-cell (FC) technology currently being considered to reduce aircraft greenhouse gas emissions may require large and heavy cooling systems. The paper introduces the two-phase (2) Mechanically Pumped Loop (MPL) for FC cooling and compares it numerically with the conventional Ethylene Glycol Water (EGW) single-phase (1) cooling system for a MW heat-dissipation load. Considering an operating temperature of 90 °C, the system mass of the 2 MPL with and without an accumulator is found to be, respectively, 33% and 64% lower than the EGW system. Furthermore, the frontal area of the ram air heat exchanger (HX) was found to be 19% smaller, reducing ram air drag. An increase of the operating temperature to 130 °C was found to reduce the cooling system mass by 21% for the 1 MPL, and 22 to 29% for the 2 MPL. The frontal area of the ram air HX was found to be reduced by 44% and 40% for the 1 and 2 MPL, respectively. These results demonstrate the considerable performance gain of the 2 MPL over the 1 MPL for FC cooling, and the benefits of increasing the operating temperature for the cooling system.