Haowei Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haowei Cao has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jianjun Ding
School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi 710049, People’s Republic of China
1 shared publication - Jinbo Guo
School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi 710049, People’s Republic of China
1 shared publication - Kunpeng Yang
School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi 710049, People’s Republic of China
1 shared publication - Qingze He
School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi 710049, People’s Republic of China
1 shared publication - Yusheng Jin
State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University 1 , Shaanxi 710049
1 shared publication - Zhenyi Wang
School of Computer Science and Technology, Xidian University, Xian, China
1 shared publication
Latest Publications
- 29 April 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (21)
Model-constrained monoscopic phase-measuring deflectometry via multi-factor iterative optimization with a priori surface knowledge
We present a model-constrained monoscopic (single-camera) phase-measuring deflectometry (PMD) framework to mitigate the height–slope ambiguity that fundamentally limits conventional single-view PMD. A priori surface knowledge, such as a nominal plane or sphere, is incorporated into a unified multi-factor iterative optimization that primarily refines the global height and pose parameters while compensating low-order reconstruction bias within a physically parameterized framework. The proposed method enables high-fidelity reconstruction without additional hardware, mechanical motion, or dual-camera calibration. Experiments on concave and planar mirrors validate the approach. For the concave mirror with a nominal radius of 151.5mm, the reconstructed radius deviates by less than 0.12% from the nominal value, with substantially improved form accuracy. Further analysis of the pose parameters demonstrates that accurate correction of tilt magnitude and azimuth is essential for suppressing low-order form errors in monoscopic PMD. In addition, repeated measurements verify the repeatability of the proposed framework. Compared with a binocular PMD baseline under the same fringe parameters, the proposed method achieves lower PV values and a fitted radius closer to the nominal value for the concave mirror while maintaining a compact single-camera configuration. This framework preserves the simplicity and flexibility of monoscopic PMD and provides a practical solution for high-precision, in-situ measurement of specular optical components.
- 29 April 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (21)
Model-constrained monoscopic phase-measuring deflectometry via multi-factor iterative optimization with a priori surface knowledge
We present a model-constrained monoscopic (single-camera) phase-measuring deflectometry (PMD) framework to mitigate the height–slope ambiguity that fundamentally limits conventional single-view PMD. A priori surface knowledge, such as a nominal plane or sphere, is incorporated into a unified multi-factor iterative optimization that primarily refines the global height and pose parameters while compensating low-order reconstruction bias within a physically parameterized framework. The proposed method enables high-fidelity reconstruction without additional hardware, mechanical motion, or dual-camera calibration. Experiments on concave and planar mirrors validate the approach. For the concave mirror with a nominal radius of 151.5mm, the reconstructed radius deviates by less than 0.12% from the nominal value, with substantially improved form accuracy. Further analysis of the pose parameters demonstrates that accurate correction of tilt magnitude and azimuth is essential for suppressing low-order form errors in monoscopic PMD. In addition, repeated measurements verify the repeatability of the proposed framework. Compared with a binocular PMD baseline under the same fringe parameters, the proposed method achieves lower PV values and a fitted radius closer to the nominal value for the concave mirror while maintaining a compact single-camera configuration. This framework preserves the simplicity and flexibility of monoscopic PMD and provides a practical solution for high-precision, in-situ measurement of specular optical components.