Muhammad Asim Mond
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Muhammad Asim Mond has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Wenwen Mei
School of Electrical Engineering Southeast University Nanjing China
1 shared publicationXiao-Ping Zhang
1 shared publicationZhou Li
School of Electrical Engineering Southeast University Nanjing China
1 shared publication- Zhou Li
School of Electrical Engineering, Southeast University, Nanjing 210096, China
1 shared publication Ziang Wei
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Recovery Control Strategies and Overcurrent Suppression for Bipolar Hybrid Cascaded MTDC Systems Under DC Faults
Bipolar hybrid cascaded multi‐terminal high‐voltage direct current (MTDC) systems feature the power density of LCCs, combined with the flexible control capabilities of the MMCs, which are suitable for long‐distance bulk power transmission and can integrate renewable energy sources on a large scale, including the Baihetan‐Jiangsu hybrid cascaded MTDC project proposed in China. The co‐existence of these converter technologies, however, leads to complicated DC fault behaviour that is very challenging to manage and recover from after faults. This paper will provide a detailed discussion of DC faults in the bipolar hybrid cascaded MTDC systems, the faults in the line‐commutated converter (LCC) section, the hybrid LCC‐MMC interface, and the modular multilevel converter (MMC) section. The electrical characteristics of DC faults are determined with the help of electromagnetic transient simulations, which consider the voltage collapse, fault current propagation, and converter stress. After being determined to have common electrical signatures and dynamic behaviours, a new classification scheme is proposed, which classifies faults that share common characteristics, dynamic responses, and system‐level responses. The control actions needed to alleviate the effects of DC faults, such as firing‐angle control of LCCs, blocking and deblocking MMCs, and coordinated AC and DC circuit breaker operation, are also another focus of this paper. It pays special attention to the effective DC fault current suppression, voltage stabilisation, and minimisation of stress on LCC and MMC converters. Moreover, the recovery strategy is worked out, and three recovery cases are investigated for each of the major categories of faults. In these cases, different control sequences, converter re‐energisation schemes, and breaker operation to stabilise the system and resume normal operation were involved. The effectiveness of the proposed fault classification, control actions, and recovery strategies is confirmed on the background of a PSCAD/EMTDC model of the Baihetan‐Jiangsu hybrid cascaded MTDC system.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Open AccessRecovery Control Strategies and Overcurrent Suppression for Bipolar Hybrid Cascaded MTDC Systems Under DC Faults
Bipolar hybrid cascaded multi‐terminal high‐voltage direct current (MTDC) systems feature the power density of LCCs, combined with the flexible control capabilities of the MMCs, which are suitable for long‐distance bulk power transmission and can integrate renewable energy sources on a large scale, including the Baihetan‐Jiangsu hybrid cascaded MTDC project proposed in China. The co‐existence of these converter technologies, however, leads to complicated DC fault behaviour that is very challenging to manage and recover from after faults. This paper will provide a detailed discussion of DC faults in the bipolar hybrid cascaded MTDC systems, the faults in the line‐commutated converter (LCC) section, the hybrid LCC‐MMC interface, and the modular multilevel converter (MMC) section. The electrical characteristics of DC faults are determined with the help of electromagnetic transient simulations, which consider the voltage collapse, fault current propagation, and converter stress. After being determined to have common electrical signatures and dynamic behaviours, a new classification scheme is proposed, which classifies faults that share common characteristics, dynamic responses, and system‐level responses. The control actions needed to alleviate the effects of DC faults, such as firing‐angle control of LCCs, blocking and deblocking MMCs, and coordinated AC and DC circuit breaker operation, are also another focus of this paper. It pays special attention to the effective DC fault current suppression, voltage stabilisation, and minimisation of stress on LCC and MMC converters. Moreover, the recovery strategy is worked out, and three recovery cases are investigated for each of the major categories of faults. In these cases, different control sequences, converter re‐energisation schemes, and breaker operation to stabilise the system and resume normal operation were involved. The effectiveness of the proposed fault classification, control actions, and recovery strategies is confirmed on the background of a PSCAD/EMTDC model of the Baihetan‐Jiangsu hybrid cascaded MTDC system.