JTJessi Truett

Jessi Truett

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jessi Truett has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sex and Beam Direction Influence the Superficial Medial Collateral Ligament Radiographic Footprint: Implications for the Femoral Reconstruction Tunnel

    by Mark Callanan, Landon Stallings, Madison Blackwell, Jessi Truett, Achraf Cohen, Mangesh Kulkarni, Adam W. Anz

    Background: Prior studies have described radiographic landmarks for medial knee procedures as single points; however, the radiographic area of the superficial medial collateral ligament (sMCL) femoral origin, sex-specific differences, and the influence of x-ray beam direction have not been well studied. Purpose: To define the entire radiographic area of the sMCL femoral origin, investigate sex-specific differences of the origin, and assess the effects of 2 different C-arm orientations on measurements. Study Design: Controlled laboratory study. Methods: The femoral origin of the sMCL was dissected in 24 cadaveric knees (12 male, 12 female), and 2-mm radiopaque ball bearings were placed at the center and the most anterior, posterior, proximal, and distal points of the footprint. Lateral radiographs of each knee were obtained with a standard C-arm from 2 positions: with the x-ray emitter on the medial side of the knee (mediolateral) and on the lateral side of the knee (lateromedial [LM]). Landmark distances from 2 reference lines and total footprint area were measured using a Digital Imaging and Communications in Medicine viewer. Results: Mean footprint area did not differ significantly between males and females (145.9 vs 140.4 mm 2 ; P = .70); however, the effect of beam orientation on footprint area differed significantly by sex ( P = .03). The female sMCL footprint was positioned approximately 4 mm more posterior ( P = .02) and 4 mm more proximal ( P = .01) than the male footprint. Beam direction also independently influenced landmark measurements ( P < .001), with LM imaging yielding more distal and posterior measurements from the reference lines and tighter grouping of anteroposterior measurements. Conclusion: The radiographic position of the sMCL femoral footprint differed by sex, with a consistent proximal and posterior shift in female specimens. Positioning the x-ray emitter on the lateral side of the knee produced tighter grouping of anteroposterior landmark measurements. Both patient sex and beam direction should be considered when using intraoperative fluoroscopy. Clinical Relevance: Sex- and beam direction–specific radiographic reference values may help guide sMCL femoral tunnel placement during less invasive, fluoroscopically guided MCL reconstruction.

  • Open Access

    Patient‐Reported Outcomes and Factors Influencing Partial‐Thickness Articular‐Sided Rotator Cuff Tear Transtendinous Repairs

    by Roger V. Ostrander, Mark Callanan, James R. Andrews, Adam W. Anz, Steve E. Jordan, Jessi Truett, Ben Sherman

    Purpose: To evaluate patient‐reported outcomes of the transtendinous repair technique for partial‐thickness articular‐sided tendon avulsions (PASTA) using patient‐acceptable symptomatic state (PASS) thresholds. Methods: Chart reviews included patients who underwent a transtendinous arthroscopic rotator cuff repair by a single surgeon for a high‐grade PASTA from January 2007 to December 2020. Inclusion criteria included patients 18 years or older who underwent surgery to repair a partial‐thickness articular‐sided rotator cuff tear. Exclusion criteria included previous ipsilateral arthroscopic shoulder procedures, rheumatoid arthritis, and severe glenohumeral arthritis. Patient‐reported outcome data, including Single Assessment Numeric Evaluation, American Shoulder and Elbow Surgeons (ASES), and visual analog scale, were retrospectively collected, as well as demographic data. These values were compared with a previously reported PASS threshold. Results: Eighty‐four patients with a mean follow‐up of 6.8 (standard deviation [SD] = 3.6) years were included in the study. All patients underwent arthroscopic rotator cuff repair for a high‐grade PASTA tear. The mean ASES index score was 90.11 (SD = 12.79) at follow‐up year (mean = 6.8, SD = 3.6), with 58 out of 84 (69%) patients meeting the PASS threshold. Seventy‐five out of 84 (89%) participants reached the PASS threshold for the Single Assessment Numeric Evaluation assessment, with a mean score of 94.18 (SD = 7.49) at follow‐up year. The mean visual analog scale was 1.24 (SD = 1.9) at follow‐up year. Fifty‐eight of 85 participants (68%) met PASS standards for both the ASES and Single Assessment Numeric Evaluation assessments. Achieving PASS in ASES was not significantly predicted by age, sex, athletic status, number of prior procedures, or lifestyle risk factors. However, participants classified as laborers showed a notable trend toward a lower likelihood of achieving PASS, suggesting that higher physical workload may negatively impact performance outcomes. Similarly, those with systemic disease tended to have reduced probability of achieving PASS. Conclusions: When clinically indicated, partial‐thickness articular‐sided rotator cuff tears can be reliably repaired via a transtendinous technique with demonstrated postoperative Patient Reported Outcomes Measures averages consistent with previously reported literature. Laborers, a Workers’ Compensation claim, and history of gout all showed significantly worse Patient Reported Outcomes Measures after PASTA repairs. Level of Evidence: Level IV, retrospective case series.

  • A Retensionable Inlay/Onlay Hybrid Double-Bundle Medial Collateral Ligament Reconstruction Produces Superior Restoration of the Uninjured State When Compared to a Single-Bundle Inlay Reconstruction

    by Adam W. Anz, Garrett Waller, Jeremy Carroll, Gabe Colbrunn, Aiden Cole Magoolaghan, Jessi Truett, Achraf Cohen, Mangesh Kulkarni, Mark C. Callanan

    Background: Traditional superficial medial collateral ligament (sMCL) reconstruction techniques have not consistently restored native laxity. Purpose/Hypothesis: The purpose of this study was to develop a retensionable inlay/onlay hybrid medial collateral ligament (MCL) reconstruction through comparison to a biomechanically and clinically validated reconstruction. It was hypothesized that increasing the distal footprint on the tibia through a double-bundle construct and a retensionable construct would better restore native laxity. Study Design: Controlled laboratory study. Methods: A total of 27 cadaveric knees were tested on a 6 degrees of freedom robot system. Knees were tested with valgus and external rotation (ER). Each knee was tested in a native state and an injured state after sectioning of the sMCL. One of 3 reconstructions using an anterior tibialis allograft was then performed: (1) single-bundle inlay reconstruction, (2) double-bundle inlay/onlay hybrid reconstruction with tibial fixation at both the proximal and distal (PD) tibial insertions of the sMCL footprint, or (3) double-bundle inlay/onlay hybrid reconstruction with tibial fixation at the anterior and posterior (AP) aspects of the distal sMCL tibial insertion. The constructs used retensionable variable-loop devices, allowing for retensioning after knee cycling. The constructs were tested after cycling and retensioning. Results: Sectioning of the sMCL resulted in significantly increased laxity compared to the native state for both valgus and ER laxity testing ( P < .001). After flexion cycling and subsequent retensioning, both AP and PD double-bundle reconstructions demonstrated significantly higher restoration of stability compared to cycled single-bundle reconstructions ( P < .001). Both double-bundle reconstructions were significantly closer to the native state than the single-bundle reconstruction for valgus rotation ( P < .001) and ER ( P < .05). For valgus testing, there was no difference between retensioned double-bundle constructs and the native state, with a pooled valgus difference of 0.56° (95% CI, 0.05°-1.06°; P = .032). For ER testing, no differences were found between the retensioned AP double-bundle and the native state ( P = .836), suggesting more complete restoration was achieved by AP double-bundle restoration. Conclusion: A retensionable inlay/onlay hybrid double-bundle MCL reconstruction with a larger femoral footprint and 2 distal anterior-posterior tibial footprints produced superior restoration of the uninjured state when compared to a traditional single-bundle inlay reconstruction. For double-bundle reconstructions, an anterior-posterior tibial fixation achieved mean values closer to the native state than proximal-distal fixation. Clinical Relevance: A double-bundle retensionable inlay/onlay hybrid reconstruction is an effective alternative to a single-bundle inlay reconstruction technique. The double-bundle reconstruction may better withstand early unrestricted range of motion during postoperative phases.

  • Open Access

    Consensus on the Treatment of Midshaft Clavicular Fractures in Collegiate Football Players: A Delphi Approach of Sports Medicine Teams

    by Adam Anz, Colin Nevins, Katie O’NEal, Micki Collins, Kevin Farmer, Jessi Truett, James R. Andrews, Michael Goodlett

    Background: Optimal management of clavicular fractures in football players remains unclear. Purpose: To utilize the Delphi process to (1) identify factors used in decision-making for clavicular fractures in collegiate football players, (2) investigate the current use of bone stimulators, teriparatide, and specialized padding as adjuncts to treatment, and (3) determine areas of consensus for treatment. Study Design: Consensus statement. Methods: A total of 83 orthopaedic surgeons, nonsurgical sports medicine physicians, and athletic trainers from the Southeastern Conference were surveyed utilizing a 3-round Delphi process. The first 2 rounds identified the most important factors that influenced treatment. These factors were combined to create 48 clinical scenarios. In the third round, panelists were presented with 8 treatment options for each scenario. Treatment options were scored as “preferred treatment,”“acceptable treatment,”“not acceptable/contraindicated,” or “unsure/no opinion.” The threshold for consensus was set at 75%. Additional questions investigated panelists’ methods for measuring displacement and shortening as well as their use of bone stimulators, teriparatide, and specialized pads. Results: All 3 rounds were completed by 43 panelists (24 orthopaedic surgeons, 4 nonoperative sports medicine physicians, and 5 athletic trainers). The top 4 factors that influenced treatment in descending order were (mean score: 1, most important; 7, least important) amount of displacement (1.16), fracture location (3.60), player input (4.07), and return-to-play timeline (4.16). Bone stimulators and specialized pads were commonly used, but teriparatide was used less frequently. Consensus analysis in round 3 only analyzed results from orthopaedic surgeons because of low response rates from nonoperative sports medicine physicians (15.4%) and athletic trainers (22.7%) compared with orthopaedic surgeons (68.6%). Panelists were more likely to reach consensus on nonoperative treatment for nondisplaced fractures without shortening early in the year and were more likely to avoid nonoperative treatment for displaced fractures with shortening. Conclusion: The current study group considers multiple clinical factors in determining optimal treatment for collegiate football players with clavicular fractures, incorporates adjuncts to traditional management, and identified a limited set of scenarios that achieved consensus.