Adnan Javed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Adnan Javed has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Abu Bakar Siddique
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
1 shared publication - Alper Uysal
Department of Mechanical Engineering, Yildiz Technical University, Istanbul, Turkey
1 shared publication Aqib Mashood Khan
1 shared publication- Aqib Mashood Khan
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
1 shared publication - Barlas Gökduman
Department of Mechanical Engineering, Yildiz Technical University, Besiktas, Istanbul 34349, Turkiye
1 shared publication - Chunjin Wang
The Hong Kong Polytechnic University
1 shared publication
Latest Publications
- Open Access
Machinability Enhancement of Ti6Al7Nb Biomedical Alloy Through MWCNT-Nanofluid MQL and Vortex Tube-Assisted Side Milling
Ti6Al7Nb biomedical alloy is difficult to machine because its low thermal conductivity and high chemical reactivity promote heat accumulation, high cutting loads, and poor surface quality. This study evaluated the side milling performance of Ti6Al7Nb under dry machining, vortex tube cooling, and MWCNT-assisted nanoparticle minimum quantity lubrication (NMQL) to identify a more sustainable and effective machining strategy. Experiments were conducted using two cutting speeds and three feed rates, and machinability was assessed in terms of cutting temperature, resultant cutting force, surface roughness, Tol wear and tool life, chip morphology, and multi-criteria ranking. Compared with dry machining, vortex tube cooling provided the strongest thermal control, reducing cutting temperature by 25–36% compared with dry conditions, owing to the cold air stream generated by the Ranque–Hilsch effect. MWCNT-NMQL produced the greatest reductions in cutting force and surface roughness, with improvements of 7–28% and 10–20%, respectively, compared with dry conditions, due to improved lubrication, reduced adhesion, possible tribofilm formation, rolling/sliding effects of MWCNTs, and enhanced heat transfer. Chip morphology observations confirmed that both assisted environments improved chip formation compared with dry machining. The overall ranking identified vortex tube cooling at Vc = 30 m/min and f = 0.08 mm/rev as the best overall condition, while NMQL was more favorable for force reduction and surface finish improvement. The findings of this study provide practical guidance for the selection of sustainable and effective cutting strategies in the precision machining of biomedical titanium alloys.
Open AccessMachinability Enhancement of Ti6Al7Nb Biomedical Alloy Through MWCNT-Nanofluid MQL and Vortex Tube-Assisted Side Milling
Ti6Al7Nb biomedical alloy is difficult to machine because its low thermal conductivity and high chemical reactivity promote heat accumulation, high cutting loads, and poor surface quality. This study evaluated the side milling performance of Ti6Al7Nb under dry machining, vortex tube cooling, and MWCNT-assisted nanoparticle minimum quantity lubrication (NMQL) to identify a more sustainable and effective machining strategy. Experiments were conducted using two cutting speeds and three feed rates, and machinability was assessed in terms of cutting temperature, resultant cutting force, surface roughness, Tol wear and tool life, chip morphology, and multi-criteria ranking. Compared with dry machining, vortex tube cooling provided the strongest thermal control, reducing cutting temperature by 25–36% compared with dry conditions, owing to the cold air stream generated by the Ranque–Hilsch effect. MWCNT-NMQL produced the greatest reductions in cutting force and surface roughness, with improvements of 7–28% and 10–20%, respectively, compared with dry conditions, due to improved lubrication, reduced adhesion, possible tribofilm formation, rolling/sliding effects of MWCNTs, and enhanced heat transfer. Chip morphology observations confirmed that both assisted environments improved chip formation compared with dry machining. The overall ranking identified vortex tube cooling at Vc = 30 m/min and f = 0.08 mm/rev as the best overall condition, while NMQL was more favorable for force reduction and surface finish improvement. The findings of this study provide practical guidance for the selection of sustainable and effective cutting strategies in the precision machining of biomedical titanium alloys.
- 10 April 2026
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 144 (3-4) , 2137-2153
Characterization of mixed spray in cryogenic MQL and its influence on milling performance of TC4 titanium alloy
- 10 April 2026
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 144 (3-4) , 2137-2153
Characterization of mixed spray in cryogenic MQL and its influence on milling performance of TC4 titanium alloy
- 13 October 2025
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 141 (1-2) , 31-76
The defect-postprocessing-lifecycle nexus: a critical review of interdependencies in metal additive-subtractive manufacturing
- 13 October 2025
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 141 (1-2) , 31-76
The defect-postprocessing-lifecycle nexus: a critical review of interdependencies in metal additive-subtractive manufacturing