Simge Tezel Yozgat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Simge Tezel Yozgat has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Aslı Karakılıç
Department of Physiology, Balıkesir University Faculty of Medicine, Balıkesir, Türkiye
2 shared publications - Cagla Bahar Bulbul
Department of Obstetrics and Gynecology, Balikesir Ataturk City and Research Hospital, Altieylul, Gaziosmanpasa, 209. Sk. No:26, 10100 Balikesir, Türkiye
2 shared publications - Cem Terece
Department of Obstetrics and Gynecology, Balikesir Ataturk City Hospital, Balikesir 10100, Turkey
2 shared publications - Emrah Özcan
Balikesir Universitesi
2 shared publications - Berrin Göktuğ Kadıoğlu
University of Health Sciences, Türkiye
1 shared publication Burak Şafak
1 shared publication
Latest Publications
- 30 September 2026
- Published by Dokuz Eyul Universitesi Saglik Bilimleri Enstitusu in Journal of Basic and Clinical Health Sciences
- Vol. 10 (3) , 350-359
Disgust Sensitivity Correlates With Empathy And Serum Vitamin D Levels in Early Pregnancy
Background and Purpose:In recent years, there has been increasing evidence demonstrating the effects on behavior of vitaminD as a “neurosteroid”. Pregnancy is a vulnerable period for vitaminD deficiency. Some structural changes occur in the social brain regions and also disgust sensitivity increases in this period. The aim of this study was to evaluate the relationship between serum vitaminD levels on both empathy and disgust sensitivity in early pregnancy.Methods:33 pregnant women whose serum vitaminD levels were previously checked during the first 20 weeks were included in the study. Disgust sensitivity and empathy scores were obtained via self-report scales. The 2D/4D digit ratio was also measured.Results:The core and total disgust sensitivity scores of the low vitaminD group were significantly higher (p=0.033 and p=0.002, respectively). Serum vitaminD levels were negatively correlated with core and total disgust sensitivity scores(p=0.014,r=-0.423 and p=0.002,r=-0.518,respectively). Total and emotional empathy scores were positively correlated with disgust sensitivity scores (p=0.038,r=0.363 and p=0.001,r=0.440,respectively). 2D/4D digit ratio was not correlated to any of the parameters.Conclusion:The routine measurement of vitaminD in early pregnancy and ensuring optimum levels with vitaminD supplementation in pregnant women with low levels may be beneficial in preventing excessive disgust sensitivity.
- 30 September 2026
- Published by Dokuz Eyul Universitesi Saglik Bilimleri Enstitusu in Journal of Basic and Clinical Health Sciences
- Vol. 10 (3) , 350-359
Disgust Sensitivity Correlates With Empathy And Serum Vitamin D Levels in Early Pregnancy
Background and Purpose:In recent years, there has been increasing evidence demonstrating the effects on behavior of vitaminD as a “neurosteroid”. Pregnancy is a vulnerable period for vitaminD deficiency. Some structural changes occur in the social brain regions and also disgust sensitivity increases in this period. The aim of this study was to evaluate the relationship between serum vitaminD levels on both empathy and disgust sensitivity in early pregnancy.Methods:33 pregnant women whose serum vitaminD levels were previously checked during the first 20 weeks were included in the study. Disgust sensitivity and empathy scores were obtained via self-report scales. The 2D/4D digit ratio was also measured.Results:The core and total disgust sensitivity scores of the low vitaminD group were significantly higher (p=0.033 and p=0.002, respectively). Serum vitaminD levels were negatively correlated with core and total disgust sensitivity scores(p=0.014,r=-0.423 and p=0.002,r=-0.518,respectively). Total and emotional empathy scores were positively correlated with disgust sensitivity scores (p=0.038,r=0.363 and p=0.001,r=0.440,respectively). 2D/4D digit ratio was not correlated to any of the parameters.Conclusion:The routine measurement of vitaminD in early pregnancy and ensuring optimum levels with vitaminD supplementation in pregnant women with low levels may be beneficial in preventing excessive disgust sensitivity.
- 4 August 2026
- Published by Elsevier in Physiology & Behavior
- Vol. 316
Affective and cognitive empathy in pregnant women and nulligravid controls: a multidimensional neuroendocrine evaluation
- 4 August 2026
- Published by Elsevier in Physiology & Behavior
- Vol. 316
Affective and cognitive empathy in pregnant women and nulligravid controls: a multidimensional neuroendocrine evaluation
- Open Access
- 22 July 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (14) , 5746
Braided Polyester Sutures with Different Manufacturing Characteristics in Cervical Cerclage: A Pilot Study Comparing Obstetric Outcomes and Operative Characteristics
Background and Objectives: The effect of suture material on clinical outcomes in cervical cerclage remains debated. This pilot study compared two braided polyester suture materials with different manufacturing characteristics (Mersilene® and Uniester®) in terms of obstetric outcomes and operative characteristics. Methods: Twenty-two pregnant women who underwent McDonald cerclage at a single center between January 2024 and December 2025 were retrospectively analyzed. Cases were divided into Mersilene® (n = 11) and Uniester® (n = 11) groups and compared regarding demographic characteristics, maternal complications, gestational age at delivery, neonatal outcomes, and operative time. Risk factors for preterm birth were assessed using multivariable logistic and linear regression analyses. Results: No significant differences were observed between groups in demographic, maternal, or neonatal outcomes. Median gestational age at delivery was 34.8 vs. 35.1 weeks (p = 1.00). Operative time was shorter in the Uniester® group, although the difference did not reach statistical significance (21.1 vs. 24.4 min; mean difference 3.3 min, 95% CI: −1.5 to 8.1; p = 0.17). Multivariable analysis identified multiple pregnancy as the only independent predictor of preterm birth (OR = 12.5, 95% CI: 1.292–120.96, p = 0.029). Conclusions: The findings of this pilot study indicate that no statistically significant differences in obstetric or neonatal outcomes were observed between the two suture materials; given the limited sample size, this should not be interpreted as evidence of equivalence. The primary determinants of pregnancy prognosis were biological parameters, primarily multiple pregnancy, rather than suture material; preoperative cervical length showed only a non-significant trend toward association. The reportedly favorable handling characteristics and the non-significantly shorter operative time associated with Uniester® may suggest a potential, though unconfirmed, technical advantage in terms of operative efficiency, particularly in time-sensitive or high-risk procedural contexts. Larger prospective multicenter studies are warranted to confirm these findings and to further evaluate whether differences in suture structure translate into clinically meaningful benefits.
- 22 July 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (14) , 5746
Open AccessBraided Polyester Sutures with Different Manufacturing Characteristics in Cervical Cerclage: A Pilot Study Comparing Obstetric Outcomes and Operative Characteristics
Background and Objectives: The effect of suture material on clinical outcomes in cervical cerclage remains debated. This pilot study compared two braided polyester suture materials with different manufacturing characteristics (Mersilene® and Uniester®) in terms of obstetric outcomes and operative characteristics. Methods: Twenty-two pregnant women who underwent McDonald cerclage at a single center between January 2024 and December 2025 were retrospectively analyzed. Cases were divided into Mersilene® (n = 11) and Uniester® (n = 11) groups and compared regarding demographic characteristics, maternal complications, gestational age at delivery, neonatal outcomes, and operative time. Risk factors for preterm birth were assessed using multivariable logistic and linear regression analyses. Results: No significant differences were observed between groups in demographic, maternal, or neonatal outcomes. Median gestational age at delivery was 34.8 vs. 35.1 weeks (p = 1.00). Operative time was shorter in the Uniester® group, although the difference did not reach statistical significance (21.1 vs. 24.4 min; mean difference 3.3 min, 95% CI: −1.5 to 8.1; p = 0.17). Multivariable analysis identified multiple pregnancy as the only independent predictor of preterm birth (OR = 12.5, 95% CI: 1.292–120.96, p = 0.029). Conclusions: The findings of this pilot study indicate that no statistically significant differences in obstetric or neonatal outcomes were observed between the two suture materials; given the limited sample size, this should not be interpreted as evidence of equivalence. The primary determinants of pregnancy prognosis were biological parameters, primarily multiple pregnancy, rather than suture material; preoperative cervical length showed only a non-significant trend toward association. The reportedly favorable handling characteristics and the non-significantly shorter operative time associated with Uniester® may suggest a potential, though unconfirmed, technical advantage in terms of operative efficiency, particularly in time-sensitive or high-risk procedural contexts. Larger prospective multicenter studies are warranted to confirm these findings and to further evaluate whether differences in suture structure translate into clinically meaningful benefits.
- 31 May 2026
- Published by Dokuz Eyul Universitesi Saglik Bilimleri Enstitusu in Journal of Basic and Clinical Health Sciences
- Vol. 10 (2) , 276-285
Superiority of MLR Over NLR and PLR In Predicting Advanced Stage Disease In Treatment-Naive Serous Ovarian Cancer
Purpose: The prognostic value of systemic inflammatory markers in ovarian cancer is contradictory. This study aimed to compare the performance of monocyte-lymphocyte ratio (MLR) in predicting advanced stage disease and peritoneal metastasis with neutrophil-lymphocyte (NLR) and platelet-lymphocyte ratio (PLR) in treatment-naive serous ovarian cancer.Material and methods: NLR, PLR, and MLR were calculated from preoperative blood samples of 63 treatment-naive ovarian cancer patients (58 serous, 92.1%) who underwent primary debulking surgery. FIGO 2021 staging criteria were used. Mann-Whitney U and Kruskal-Wallis tests (with Bonferroni correction) were used for intergroup comparisons; multivariate logistic regression analysis was applied to determine independent predictors. The discriminative performance of MLR was evaluated using ROC analysis.Results: 92.1% of the cohort had serous histology, and 61.9% had advanced-stage disease (FIGO stages III-IV). In multivariate analysis (adjusted for age and menopause), only MLR was found to be independently associated with advanced-stage disease (adjusted OR: 4.25; 95% CI: 1.24-14.49; p=0.021). NLR and PLR showed no significance. MLR was also associated with peritoneal metastasis (p=0.017) and intestinal infiltration (p=0.019). In ROC analysis, the AUC was 0.706 (95% CI: 0.567-0.845; p=0.006). The optimal cut-off value was determined as 0.30 (sensitivity 48.7%, specificity 91.7%); an alternative cut-off value of 0.17 (sensitivity 82.1%, specificity 50.0%) was evaluated for high sensitivity. Conclusion: In treatment-naive serous ovarian cancer, MLR demonstrated superior performance compared to NLR and PLR in predicting advanced disease and peritoneal metastasis (adjusted OR: 4.25; AUC: 0.706). This finding supports the clinical significance of the monocyte-macrophage axis in serous ovarian cancer with predominantly transcoelomic spread. The prognostic value and optimal cut-off values of MLR should be confirmed by prospective multicenter studies.
- 31 May 2026
- Published by Dokuz Eyul Universitesi Saglik Bilimleri Enstitusu in Journal of Basic and Clinical Health Sciences
- Vol. 10 (2) , 276-285
Superiority of MLR Over NLR and PLR In Predicting Advanced Stage Disease In Treatment-Naive Serous Ovarian Cancer
Purpose: The prognostic value of systemic inflammatory markers in ovarian cancer is contradictory. This study aimed to compare the performance of monocyte-lymphocyte ratio (MLR) in predicting advanced stage disease and peritoneal metastasis with neutrophil-lymphocyte (NLR) and platelet-lymphocyte ratio (PLR) in treatment-naive serous ovarian cancer.Material and methods: NLR, PLR, and MLR were calculated from preoperative blood samples of 63 treatment-naive ovarian cancer patients (58 serous, 92.1%) who underwent primary debulking surgery. FIGO 2021 staging criteria were used. Mann-Whitney U and Kruskal-Wallis tests (with Bonferroni correction) were used for intergroup comparisons; multivariate logistic regression analysis was applied to determine independent predictors. The discriminative performance of MLR was evaluated using ROC analysis.Results: 92.1% of the cohort had serous histology, and 61.9% had advanced-stage disease (FIGO stages III-IV). In multivariate analysis (adjusted for age and menopause), only MLR was found to be independently associated with advanced-stage disease (adjusted OR: 4.25; 95% CI: 1.24-14.49; p=0.021). NLR and PLR showed no significance. MLR was also associated with peritoneal metastasis (p=0.017) and intestinal infiltration (p=0.019). In ROC analysis, the AUC was 0.706 (95% CI: 0.567-0.845; p=0.006). The optimal cut-off value was determined as 0.30 (sensitivity 48.7%, specificity 91.7%); an alternative cut-off value of 0.17 (sensitivity 82.1%, specificity 50.0%) was evaluated for high sensitivity. Conclusion: In treatment-naive serous ovarian cancer, MLR demonstrated superior performance compared to NLR and PLR in predicting advanced disease and peritoneal metastasis (adjusted OR: 4.25; AUC: 0.706). This finding supports the clinical significance of the monocyte-macrophage axis in serous ovarian cancer with predominantly transcoelomic spread. The prognostic value and optimal cut-off values of MLR should be confirmed by prospective multicenter studies.
- Open Access
- 1 January 2026
- Published by Walter de Gruyter GmbH in Case Reports in Perinatal Medicine
- Vol. 15 (1)
Late-onset spontaneous chorioamniotic membrane separation mimicking amniotic band sequence with rapid progression to preterm premature rupture of membranes
Objectives: Spontaneous chorioamniotic membrane separation (CMS) diagnosed in the third trimester is rare, and its short-term clinical course remains poorly characterized. We report a case of late-onset CMS with rapid progression to preterm premature rupture of membranes (PPROM). Case presentation: A 23-year-old woman with a prior cesarean delivery was referred at 35 weeks for suspected fetal macrosomia. At 36+4 weeks, ultrasonography revealed freely mobile, multilayered membranes adjacent to the fetal extremities and umbilical cord, raising concern for amniotic band sequence. Detailed anatomical assessment and color Doppler evaluation demonstrated intact extremities and preserved distal perfusion, supporting a diagnosis of CMS. The patient was admitted for surveillance, and PPROM occurred within hours of diagnosis. Cesarean delivery resulted in a live male infant weighing 4,170 g (Apgar scores 8/9). Intraoperative findings confirmed near-complete amnion–chorion separation. Conclusions: Late-onset spontaneous CMS may mimic amniotic band sequence and can progress rapidly to membrane rupture. Careful sonographic differentiation is essential. Given the potential for rapid clinical deterioration, close surveillance may be warranted, particularly in late gestation.
- 1 January 2026
- Published by Walter de Gruyter GmbH in Case Reports in Perinatal Medicine
- Vol. 15 (1)
Open AccessLate-onset spontaneous chorioamniotic membrane separation mimicking amniotic band sequence with rapid progression to preterm premature rupture of membranes
Objectives: Spontaneous chorioamniotic membrane separation (CMS) diagnosed in the third trimester is rare, and its short-term clinical course remains poorly characterized. We report a case of late-onset CMS with rapid progression to preterm premature rupture of membranes (PPROM). Case presentation: A 23-year-old woman with a prior cesarean delivery was referred at 35 weeks for suspected fetal macrosomia. At 36+4 weeks, ultrasonography revealed freely mobile, multilayered membranes adjacent to the fetal extremities and umbilical cord, raising concern for amniotic band sequence. Detailed anatomical assessment and color Doppler evaluation demonstrated intact extremities and preserved distal perfusion, supporting a diagnosis of CMS. The patient was admitted for surveillance, and PPROM occurred within hours of diagnosis. Cesarean delivery resulted in a live male infant weighing 4,170 g (Apgar scores 8/9). Intraoperative findings confirmed near-complete amnion–chorion separation. Conclusions: Late-onset spontaneous CMS may mimic amniotic band sequence and can progress rapidly to membrane rupture. Careful sonographic differentiation is essential. Given the potential for rapid clinical deterioration, close surveillance may be warranted, particularly in late gestation.