Ulysses Tachibana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ulysses Tachibana has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Bernardo Kaplan Moscovici
Department of Ophthalmology and Visual Sciences, Universidade Federal de São Paulo, São Paulo, Brazil; Postgraduate Program in Translational Medicine, Department of Medicine, Escola Paulista de Medicina, Federal University of São Paulo, São Paulo, Brazil; Department of Ophthalmology, Laser Vision Hospital, Santos, São Paulo, Brazil
1 shared publication - Caio Henrique Peres Oliani
Hospital Visão Laser
1 shared publication - Camyla Lemos Budib
Department of Ophthalmology, Hospital Visão Laser, Santos, SP, Brazil
1 shared publication - Guilherme Novoa Colombo-Barboza
Department of Ophthalmology, Hospital Visão Laser, Santos, Brazil
1 shared publication - Guilherme de Oliveira Ferreira
Universidade de Brasilia, Brasilia, DF, Brazil
1 shared publication - José Álvaro Pereira Gomes
Department of Ophthalmology and Visual Science, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil
1 shared publication
Latest Publications
- 1 January 2026
- Published by GN1 Sistemas e Publicacoes Ltd. in Arquivos Brasileiros de Oftalmologia
- Vol. 89 (3) , 01-09
Reliability of a Scheimpflug-based tomographer compared with a Placido-based topographer and specular microscopy in healthy eyes
To evaluate the reliability and comparability of a Scheimpflug-based tomographer relative to a Placido-based topographer and specular microscopy in healthy eyes. This cross-sectional study included 40 patients (80 eyes). Each eye underwent randomized imaging with a Scheimpflug-based tomographer, a Placido-based topographer, and Tomey EM-4000 specular microscopy. Three acquisitions per device were obtained. For interdevice comparisons, the best-quality scan per eye/device was selected, whereas all three scans were used for intradevice repeatability analyses. Unreliable scans were repeated (up to five attempts) and excluded if acceptable quality was not achieved, resulting in variable denominators. Between-device comparisons were performed using generalized estimating equations with participant-level clustering and robust standard errors and were supplemented by Bland-Altman analysis. The effective sample size varied by parameter (independent summaries: 59-67 eyes; paired comparisons: 48-51 eyes). In paired-eye analyses, the Scheimpflug-based tomographer measured slightly higher keratometry values than the Placido-based topographer (K1: 43.95 vs. 43.78 D, p=0.003; K2: 44.91 vs 44.73 D, p=0.002), more negative Q-values (p=0.001), smaller photopic pupil diameter (p<0.001), and shorter kappa distance (p<0.001). Mean absolute differences were 0.32 D for K1 and 0.30 D for K2, with high dispersion for angular metrics (kappa angle coefficient of variation: 195%). The Scheimpflug-based tomographer provides reproducible corneal measurements in healthy eyes. However, systematic differences relative to the Placido-based topographer-particularly for keratometry, asphericity, and pupil and kappa metrics-suggest limited interchangeability. Consistent device use is recommended when these parameters inform clinical decision-making.
- 1 January 2026
- Published by GN1 Sistemas e Publicacoes Ltd. in Arquivos Brasileiros de Oftalmologia
- Vol. 89 (3) , 01-09
Reliability of a Scheimpflug-based tomographer compared with a Placido-based topographer and specular microscopy in healthy eyes
To evaluate the reliability and comparability of a Scheimpflug-based tomographer relative to a Placido-based topographer and specular microscopy in healthy eyes. This cross-sectional study included 40 patients (80 eyes). Each eye underwent randomized imaging with a Scheimpflug-based tomographer, a Placido-based topographer, and Tomey EM-4000 specular microscopy. Three acquisitions per device were obtained. For interdevice comparisons, the best-quality scan per eye/device was selected, whereas all three scans were used for intradevice repeatability analyses. Unreliable scans were repeated (up to five attempts) and excluded if acceptable quality was not achieved, resulting in variable denominators. Between-device comparisons were performed using generalized estimating equations with participant-level clustering and robust standard errors and were supplemented by Bland-Altman analysis. The effective sample size varied by parameter (independent summaries: 59-67 eyes; paired comparisons: 48-51 eyes). In paired-eye analyses, the Scheimpflug-based tomographer measured slightly higher keratometry values than the Placido-based topographer (K1: 43.95 vs. 43.78 D, p=0.003; K2: 44.91 vs 44.73 D, p=0.002), more negative Q-values (p=0.001), smaller photopic pupil diameter (p<0.001), and shorter kappa distance (p<0.001). Mean absolute differences were 0.32 D for K1 and 0.30 D for K2, with high dispersion for angular metrics (kappa angle coefficient of variation: 195%). The Scheimpflug-based tomographer provides reproducible corneal measurements in healthy eyes. However, systematic differences relative to the Placido-based topographer-particularly for keratometry, asphericity, and pupil and kappa metrics-suggest limited interchangeability. Consistent device use is recommended when these parameters inform clinical decision-making.