Talya Salant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Talya Salant has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Adam Rodman
Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts
1 shared publication Anthony Zhong
1 shared publication- Betsy Lowe
Patient and Family Advisory Council, Beth Israel Deaconess Medical Center, Boston, Massachusetts
1 shared publication - Chase Walton
Department of Biochemistry and Molecular Biology, Medical University of South Carolina, Charleston, South Carolina
1 shared publication - Eric J. Thomas
Internal Medicine, University of Texas John P and Katherine G McGovern Medical School, Houston, Texas, USA
1 shared publication - Fabienne C. Bourgeois
Division of General Pediatrics, Children's Hospital Boston, Boston, MA 02115, USA
1 shared publication
Latest Publications
- Open Access
Development and Preliminary Evaluation of the Patient–Artificial Intelligence Rating Instrument
Importance: Patients increasingly use artificial intelligence (AI) for health-related conversations, but evaluation measures largely reflect clinician judgment. Objective: To develop and preliminarily evaluate a patient instrument assessing the quality of patient–AI health conversations. Design: Cross-sectional survey conducted June 5-14, 2026, following patient-partnered instrument development and cognitive interviews. Setting: An anonymous online survey. Participants: A convenience sample of adults with prior use of large language models for personal health-related queries, recruited from an academic medical center-affiliated Insight Panel and patient peers. Exposures: Participants’ own prior health-related conversations with AI tools of their choosing. Main Outcomes and Measures: The Patient-AI Rating instrument comprised 12 communication-quality and patient engagement items rated from 1 to 5 and a separately scored patient-perceived-harm item. Internal consistency was assessed using Cronbach α, with sensitivity analyses using first ratings only for those using the tool to rate multiple conversations and participant-mean profiles. We examined item–total correlations, inter-item structure, and between- and within-participant variation. Results: Fourteen participants contributed 46 complete ratings; among 13 providing demographics, median age was 63 years (IQR, 53-70 years), and 8 (62%) reported female gender. Participants provided a median of 2 ratings (range, 1-17). Cronbach α was 0.88 (95% CI, 0.83-0.93) across all ratings, 0.85 using first ratings only, and 0.92 using participant-mean profiles. Corrected item–total correlations ranged from 0.42 to 0.72; mean inter-item correlation was 0.40. No item deletion improved Cronbach α. The mean quality score was 4.43 (SD, 0.45). Among 9 participants contributing multiple ratings, the intraclass correlation coefficient was 0.45, suggesting inter-conversation variability. No perceived harm was reported in 44 of 46 ratings (96%); the harm item correlated minimally with the instrument total (r = 0.09). Conclusions and Relevance: In this small cross-sectional study of engaged patients, the Patient-AI Rating instrument showed promising internal consistency and variation across rated conversations. These findings support further evaluation of patient-reported communication quality alongside clinician-based measures. Validation in larger, more diverse populations, including assessment of construct and criterion validity, is needed before broader use. Key Points: Question: Can a patient instrument measure the quality of patients’ health-related conversations with artificial intelligence (AI)? Findings: In this cross-sectional study, 14 participants provided 46 ratings of their health-related AI conversations using a 12-item scale and a perceived-harm item (the Patient AI Rating (PAIR) instrument). The patient metric showed good internal consistency, and scores varied both by raters and across conversations rated by the same participant. Meaning: The PAIR instrument offers a preliminary approach to incorporate patient perspective and experience into AI evaluation – a measure largely missing from current AI assessment; larger studies are needed to establish validity and generalizability.
Open AccessDevelopment and Preliminary Evaluation of the Patient–Artificial Intelligence Rating Instrument
Importance: Patients increasingly use artificial intelligence (AI) for health-related conversations, but evaluation measures largely reflect clinician judgment. Objective: To develop and preliminarily evaluate a patient instrument assessing the quality of patient–AI health conversations. Design: Cross-sectional survey conducted June 5-14, 2026, following patient-partnered instrument development and cognitive interviews. Setting: An anonymous online survey. Participants: A convenience sample of adults with prior use of large language models for personal health-related queries, recruited from an academic medical center-affiliated Insight Panel and patient peers. Exposures: Participants’ own prior health-related conversations with AI tools of their choosing. Main Outcomes and Measures: The Patient-AI Rating instrument comprised 12 communication-quality and patient engagement items rated from 1 to 5 and a separately scored patient-perceived-harm item. Internal consistency was assessed using Cronbach α, with sensitivity analyses using first ratings only for those using the tool to rate multiple conversations and participant-mean profiles. We examined item–total correlations, inter-item structure, and between- and within-participant variation. Results: Fourteen participants contributed 46 complete ratings; among 13 providing demographics, median age was 63 years (IQR, 53-70 years), and 8 (62%) reported female gender. Participants provided a median of 2 ratings (range, 1-17). Cronbach α was 0.88 (95% CI, 0.83-0.93) across all ratings, 0.85 using first ratings only, and 0.92 using participant-mean profiles. Corrected item–total correlations ranged from 0.42 to 0.72; mean inter-item correlation was 0.40. No item deletion improved Cronbach α. The mean quality score was 4.43 (SD, 0.45). Among 9 participants contributing multiple ratings, the intraclass correlation coefficient was 0.45, suggesting inter-conversation variability. No perceived harm was reported in 44 of 46 ratings (96%); the harm item correlated minimally with the instrument total (r = 0.09). Conclusions and Relevance: In this small cross-sectional study of engaged patients, the Patient-AI Rating instrument showed promising internal consistency and variation across rated conversations. These findings support further evaluation of patient-reported communication quality alongside clinician-based measures. Validation in larger, more diverse populations, including assessment of construct and criterion validity, is needed before broader use. Key Points: Question: Can a patient instrument measure the quality of patients’ health-related conversations with artificial intelligence (AI)? Findings: In this cross-sectional study, 14 participants provided 46 ratings of their health-related AI conversations using a 12-item scale and a perceived-harm item (the Patient AI Rating (PAIR) instrument). The patient metric showed good internal consistency, and scores varied both by raters and across conversations rated by the same participant. Meaning: The PAIR instrument offers a preliminary approach to incorporate patient perspective and experience into AI evaluation – a measure largely missing from current AI assessment; larger studies are needed to establish validity and generalizability.
- 2 June 2026
- Published by Elsevier in The Joint Commission Journal on Quality and Patient Safety
- Vol. 52 (10) , 544-550
Symptom Tracking in Primary Care: Designing and Testing an EHR–Embedded Safety-Net System
- 2 June 2026
- Published by Elsevier in The Joint Commission Journal on Quality and Patient Safety
- Vol. 52 (10) , 544-550
Symptom Tracking in Primary Care: Designing and Testing an EHR–Embedded Safety-Net System