RBRobert Bielitzki

Robert Bielitzki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Robert Bielitzki has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Alexander Franz

    Department of Orthopedics and Trauma Surgery, University Hospital Bonn

    1 shared publication
  • Constantin Wilhelm Freitag

    Department of Sport Science, Institute III, Otto von Guericke University Magdeburg, Zschokkestraße 32, 39104 Magdeburg, Germany

    1 shared publication
  • Cynthia Moffack Djuloun

    Section for Clinical and Experimental Sensory Physiology, Ophthalmic Department, University Hospital Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany

    1 shared publication
  • Francie H. Stolle

    Section for Clinical and Experimental Sensory Physiology, Ophthalmic Department, University Hospital Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany

    1 shared publication
  • Hagen Thieme

    Section for Clinical and Experimental Sensory Physiology, Ophthalmic Department, University Hospital Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany

    1 shared publication
  • Jan Peter Latendorf

    Chair of Health and Physical Activity, Department of Sport Science, Institute III, Otto-von-Guericke University Magdeburg

    1 shared publication

Latest Publications

  • Open Access

    Effects of a Multimodal Exercise Intervention on Single- and Dual-Task Gait Performance in Older Patients with Open-Angle Glaucoma: A Pilot Study

    by Constantin W. Freitag, Martin Behrens, Robert Bielitzki, Tom Behrendt, Khaldoon O. Al-Nosairy, Cynthia Moffack Djuloun, Francie H. Stolle, Hagen Thieme, Michael B. Hoffmann, Lutz Schega

    Background/Objectives: To investigate the effects of a 12-week multimodal intervention (MMI [resistance + motor-cognitive dual-task training]) versus a unimodal intervention (UMI [resistance training]) on gait and cognitive performance in people with glaucoma during single-task (ST) and dual-task (DT) walking. Methods: In this randomized controlled pilot study, fifteen glaucoma patients (MMI: n = 8, UMI: n = 7) completed 24 supervised intervention sessions over 12 weeks. Spatio-temporal gait parameters (stride length, gait velocity, minimum toe clearance [MTC], and their respective coefficient of variance [CoV]) were assessed using inertial measurement units (sampling frequency 100 Hz) during ST and DT walking. During DT walking, the participants performed three cognitive tasks: reaction time task, N-Back task, and letter fluency task. Each cognitive task was performed with two levels of difficulty. Repeated measures analysis of covariance (TIME × INTERVENTION × CONDITION) was conducted to analyze the data. Results: No significant group or time effects were observed for ST walking or cognitive performance. Independent of intervention, dual-task costs (DTC) improved for MTC (p = 0.188, ηp2 = 0.205) and MTCCoV (p = 0.021, ηp2 = 0.713) over time. UMI showed greater improvements over time than MMI for DTC MTC (p = 0.168, ηp2 = 0.223) and DTC MTCCoV (p = 0.047, ηp2 = 0.407). Conclusions: This pilot study indicated that both MMI and UMI decreased DTC MTC and DTC MTCCoV in glaucoma patients, with probably higher effects after UMI. These preliminary findings must be interpreted with caution due to the small sample size, but the provided effect size measures and sample size calculations can be used for future randomized controlled trials to verify and extend these results.

  • Open Access

    Does exercising bilaterally require measuring bilaterally? Bilateral versus unilateral tourniquet cuff inflation during measurement of arterial occlusion pressure: considerations for blood flow restriction exercise

    by Robert Bielitzki, Tom Behrendt, Martin Behrens, Jan Peter Latendorf, Alexander Franz, Luke Hughes, Lutz Schega

    Introduction: It is recommended to use a tourniquet cuff pressure between 40-80% of the individuals’ arterial occlusion pressure (AOP) during blood flow restriction (BFR) exercise. The AOP is usually determined in one limb for unilateral BFR exercise or in both limbs individually for bilateral BFR exercise. However, given that the tourniquet cuffs are inflated at both limbs simultaneously during bilateral BFR exercises (e.g., cycling, walking, and squat exercise), it is currently not known if the respective AOP also needs to be determined during bilateral tourniquet cuff inflation. Consequently, the present study aimed to compare the AOP during unilateral versus bilateral tourniquet cuff inflation in the lower extremities. Methods: In a randomized cross-over trial, the AOP of 25 young healthy participants was determined during unilateral and bilateral tourniquet cuff inflation in supine, seated, and standing position. All measurements were completed in one experimental session with a rest period of 5 min in between. At the beginning and end of each condition, heart rate and blood pressure were recorded. Results: Regardless of body position, AOP was higher during bilateral compared to unilateral tourniquet cuff inflation ( mean difference = 3.2 mmHg [ 95% confidence interval : 1.0, 5.4], p = 0.006, d = 0.12). Furthermore, AOP and heart rate increased with change in body position from supine to seated to standing position ( p < 0.001, d ≥ 0.76). Discussion: Even though there was a statistically significant difference in AOP between unilateral and bilateral tourniquet cuff inflation irrespective of body position, bilateral cuff inflation during AOP determination appears to have only minor impact on AOP in the lower extremities given the small mean difference and trivial effect size. However, since differences in AOP between unilateral and bilateral tourniquet cuff inflation of ≥ 30 mmHg have been recorded, practitioners must be aware of potentially pronounced differences between unilateral and bilateral cuff inflation during AOP determination in some individuals using the specific BFR device and AOP measurement protocol employed in this study. These results need to be verified for different inflation protocols, devices (i.e., manual versus automatic AOP determination), and populations (e.g., older adults, patients).