Yuyao Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuyao Feng has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Aiqiang Pan
State Grid Shanghai Electric Power Research Institute, Shanghai 200437, China
1 shared publication - Nan Feng
State Grid Shanghai Electric Power Research Institute, Shanghai 200437, China
1 shared publication - Qiang Guo
State Grid Shanghai Electric Power Research Institute, Shanghai 200437, China
1 shared publication - Tao Niu
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China
1 shared publication
Latest Publications
- Open Access
Optimal Configuration Strategy for Flexible DC Control Parameters Considering System Operational Constraints
With the large-scale integration of renewable energy sources, the stability and control of flexible DC (VSC-HVDC) grid-connected systems have become critical issues. This paper proposes an optimal configuration strategy for the control parameters of grid-forming VSC-HVDC systems considering multiple operational constraints. First, a state-space model of the grid-forming VSC-HVDC system connected to a wind farm is established, and the effects of key control parameters on the small-signal stability are analyzed using eigenvalue and participation factor methods. Then, based on the stability analysis, an optimization model is constructed with the objectives of minimizing the steady-state DC operating voltage under operational constraints and maximizing system damping. To solve the optimization problem, the NSGA-II genetic algorithm is employed. Case studies in MATLAB/Simulink demonstrate that the proposed method effectively enhances the small-signal stability of the system across various operating points, reduces overshoot and settling time during power step changes, and ensures stable operation under the maximum transferable power limit. The results verify the robustness and effectiveness of the proposed parameter configuration strategy, providing a practical approach for the design and tuning of grid-forming VSC-HVDC systems in renewable energy integration applications.
Open AccessOptimal Configuration Strategy for Flexible DC Control Parameters Considering System Operational Constraints
With the large-scale integration of renewable energy sources, the stability and control of flexible DC (VSC-HVDC) grid-connected systems have become critical issues. This paper proposes an optimal configuration strategy for the control parameters of grid-forming VSC-HVDC systems considering multiple operational constraints. First, a state-space model of the grid-forming VSC-HVDC system connected to a wind farm is established, and the effects of key control parameters on the small-signal stability are analyzed using eigenvalue and participation factor methods. Then, based on the stability analysis, an optimization model is constructed with the objectives of minimizing the steady-state DC operating voltage under operational constraints and maximizing system damping. To solve the optimization problem, the NSGA-II genetic algorithm is employed. Case studies in MATLAB/Simulink demonstrate that the proposed method effectively enhances the small-signal stability of the system across various operating points, reduces overshoot and settling time during power step changes, and ensures stable operation under the maximum transferable power limit. The results verify the robustness and effectiveness of the proposed parameter configuration strategy, providing a practical approach for the design and tuning of grid-forming VSC-HVDC systems in renewable energy integration applications.