Hanxing Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hanxing Wang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Yixuan Deng
Beihang University
2 shared publications - Yusen Li2 shared publications
- Yuzheng Ma
Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, People’s Republic of China
2 shared publications - Fan Yang
Beihang University
1 shared publication - Leran Zhang
Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, People’s Republic of China
1 shared publication - Minxia Shi
Beihang University
1 shared publication
Latest Publications
- 27 October 2026
- Published by Elsevier in Measurement
- Vol. 293
Magnetic-noise calculation model incorporating frequency and magnetic-field-strength effects for magnetically shielded rooms
- 27 October 2026
- Published by Elsevier in Measurement
- Vol. 293
Magnetic-noise calculation model incorporating frequency and magnetic-field-strength effects for magnetically shielded rooms
- Open Access
- 1 June 2026
- Published by Elsevier in SSRN Electronic Journal
The Regulation Method of Magnetization State for Magnetic Shielding Devices Using the MSD-R-D System Based on Ant Colony Algorithm and Local Flux Detection
Magnetic shielding devices (MSD) constitute essential infrastructure for realizing near-zero magnetic field environments and enabling high-precision quantum magnetic measurements. The performance of these devices is governed by the magnetization state of the high-permeability permalloy of the MSD. However, conventional testing and degaussing techniques are incapable of precisely detecting or regulating the local magnetization state of the MSD. To overcome this limitation, this paper proposes an MSD-R-D system that enables uniform regulation and global detection of the magnetization state of the MSD. A path-planning approach based on the ant colony algorithm is adopted to design the regulation coil, thereby generating a highly uniform excitation magnetic field. Furthermore, a B probe-type sensor integrated with a signal processing module is utilized to achieve localized measurement of the magnetic flux density on the MSD surface. Experimental results demonstrate that, after applying the MSD-R-D system, the MSD exhibits a uniform surface flux distribution, high consistency in the magnetization process, and substantially improved shielding performance, thereby validating the efficiency of the proposed system.
- 1 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThe Regulation Method of Magnetization State for Magnetic Shielding Devices Using the MSD-R-D System Based on Ant Colony Algorithm and Local Flux Detection
Magnetic shielding devices (MSD) constitute essential infrastructure for realizing near-zero magnetic field environments and enabling high-precision quantum magnetic measurements. The performance of these devices is governed by the magnetization state of the high-permeability permalloy of the MSD. However, conventional testing and degaussing techniques are incapable of precisely detecting or regulating the local magnetization state of the MSD. To overcome this limitation, this paper proposes an MSD-R-D system that enables uniform regulation and global detection of the magnetization state of the MSD. A path-planning approach based on the ant colony algorithm is adopted to design the regulation coil, thereby generating a highly uniform excitation magnetic field. Furthermore, a B probe-type sensor integrated with a signal processing module is utilized to achieve localized measurement of the magnetic flux density on the MSD surface. Experimental results demonstrate that, after applying the MSD-R-D system, the MSD exhibits a uniform surface flux distribution, high consistency in the magnetization process, and substantially improved shielding performance, thereby validating the efficiency of the proposed system.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 9542313
High-Fidelity Magnetic Imaging via Active Decoupling for SERF Magnetometer Arrays
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 9542313
High-Fidelity Magnetic Imaging via Active Decoupling for SERF Magnetometer Arrays