Panavy Pookaiyaudom
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Panavy Pookaiyaudom has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Panlop Puntuprecharat
Department of Electronic Engineering, School of Electrical and Electronic Engineering (SEE), Mahanakorn University of Technology, Nongchok, Bangkok 10530, Thailand
1 shared publication - Phimchanok Sakunpongpitiporn
Conductive and Electroactive Polymers Research Unit, The Petroleum and Petrochemical College, Chulalongkorn University, Bangkok 10330, Thailand
1 shared publication - Pipat Sakarin
Department of Electronic Engineering, School of Electrical and Electronic Engineering (SEE), Faculty of Engineering and Technology, Mahanakorn University of Technology, Nongchok, Bangkok 10530, Thailand
1 shared publication - Prajuab Pawarangkoon
Department of Electronic Engineering, School of Electrical and Electronic Engineering (SEE), Mahanakorn University of Technology, Nongchok, Bangkok 10530, Thailand
1 shared publication - Suchada Sitjongsataporn
Mahanakorn University of Technology
1 shared publication
Latest Publications
- Open Access
A Robust Current-Feedback Operational Amplifier-Based Front-End Amplifier for Electrocardiogram Signal Noise Removal
This paper introduces an electrocardiogram (ECG) noise removal front-end amplifier circuit based on a current-feedback operational amplifier (CFOA) that uses the current feedback to detect error signals and control the output. This ECG circuit focuses on denoising the ECG noise to accentuate the ECG electrical signals from the heart. Noises in ECG refer to baseline wander (BW), powerline interference (PLI) and motion artifacts. We proposed a CFOA-based ECG pre-amplifier using the AD844 commercial operational amplifier built inside with a positive second-generation current conveyor (CCII+) and a voltage follower circuit. This work introduces an ECG noise removal front-end amplifier based on a CFOA. The primary innovation lies in the balancing instrumentation amplifier architecture that utilizes the high-speed and robust properties of the AD844 commercial operational amplifier to achieve superior noise rejection. To protect against high-frequency interference, we introduce a novel cascaded low-pass filter (LPF) stage that ensures a sharper cut-off compared to traditional single-stage designs. Experimental results validate the design’s effectiveness, achieving a high common-mode rejection ratio (CMRR) of 75.4 dB and a mid-band gain of 46.5 dB. These performance metrics, combined with the circuit’s ability to eliminate BW and PLI, confirm its robust suitability for high-fidelity wearable ECG monitoring.
Open AccessA Robust Current-Feedback Operational Amplifier-Based Front-End Amplifier for Electrocardiogram Signal Noise Removal
This paper introduces an electrocardiogram (ECG) noise removal front-end amplifier circuit based on a current-feedback operational amplifier (CFOA) that uses the current feedback to detect error signals and control the output. This ECG circuit focuses on denoising the ECG noise to accentuate the ECG electrical signals from the heart. Noises in ECG refer to baseline wander (BW), powerline interference (PLI) and motion artifacts. We proposed a CFOA-based ECG pre-amplifier using the AD844 commercial operational amplifier built inside with a positive second-generation current conveyor (CCII+) and a voltage follower circuit. This work introduces an ECG noise removal front-end amplifier based on a CFOA. The primary innovation lies in the balancing instrumentation amplifier architecture that utilizes the high-speed and robust properties of the AD844 commercial operational amplifier to achieve superior noise rejection. To protect against high-frequency interference, we introduce a novel cascaded low-pass filter (LPF) stage that ensures a sharper cut-off compared to traditional single-stage designs. Experimental results validate the design’s effectiveness, achieving a high common-mode rejection ratio (CMRR) of 75.4 dB and a mid-band gain of 46.5 dB. These performance metrics, combined with the circuit’s ability to eliminate BW and PLI, confirm its robust suitability for high-fidelity wearable ECG monitoring.